NetVanta 6310/6330 Series Hardware Installation Guide
Unit Installation
61700100G1-34F
Copyright © 2013 ADTRAN, Inc.
37
5.
UNIT INSTALLATION
The instructions and guidelines provided in this section cover hardware installation topics, such as mounting
options, supplying power to the unit, and installing option cards. These instructions are presented as follows:
•
Tools Required on page 37
•
Mounting Options on page 38
•
Supplying Power to the Unit on page 40
For information on configuring a specific application, refer to the configuration guides provided on the
ADTRAN’s Support Forum
or the
AOS Command Reference Guide
.
Tools Required
The customer-provided tools required for the hardware installation of the NetVanta are:
•
Ethernet cables
•
Network cables (module dependent)
•
Phillips-head screwdriver (rackmount applications only)
•
Drill and drill bit set (wallmount applications only)
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
•
The NetVanta 6310/6330 Series is intended to be installed, maintained, and serviced by
qualified service personnel only and should be installed in a restricted access location
as described in UL/IEC 60950-1.
•
Ethernet cables are intended for intrabuilding use only. Connecting an ADTRAN unit
directly to Ethernet cables that run outside the building in which the unit is housed will
void the user's warranty and could create a fire or shock hazard. To connect an
ADTRAN unit to Ethernet cables that run outside the building, ADTRAN's Ethernet
Port Protection Device (EPPD) (P/N 1700502G1) must be connected between the unit
and the outside plant cable. Use of any Ethernet protector other than ADTRAN's for this
purpose will void the user's warranty.
Electronic modules can be damaged by static electrical discharge. Before handling
modules, put on an antistatic discharge wrist strap to prevent damage to electrical
components. Place modules in antistatic packing material when transporting or storing.
When working on modules, always place them on an approved antistatic mat that is
electrically grounded.
To access the CLI of the NetVanta, you will also need a PC with terminal emulation
software and a console port cable. Instructions on how to access the CLI are available in
the quick start guide shipped with your unit or online at
ADTRAN’s Support Forum
.