background image

 Physical Descriptions

NetVanta 3200/3300/3400 Series

 36

Copyright © 2012 ADTRAN, Inc.

61200860L1-34AB

Power Connection

All of the 1U-high products have universal power supplies and are shipped with the appropriate cable. 
Please refer to 

Supplying Power to the Unit on page 69

 for connection details.

NetVanta 3458

The NetVanta 3458 is a high-performance, modular IP access router designed for cost-effective branch 
office connectivity over MPLS, Frame Relay, multilink Frame Relay, PPP, MLPPP, or Ethernet networks. 
It offers an integrated 8-port fully managed Ethernet switch. 

The NetVanta 3458 switch ports can be upgraded using the Octal Power over Ethernet (PoE) Upgrade 
Bundle to provide PoE capability. PoE provides the ability to detect attached powered devices (PDs) and 
deliver 48 VDC to the PDs via existing CAT 5 cabling. The NetVanta 3458 PoE option is fully compliant 
with the IEEE 802.3af PoE standard.

For information on switch configuration for a specific application, refer to the configuration guides provided on 
the 

ADTRAN Support Community

. For details on the command line interface (CLI), refer to the 

AOS 

Command Reference Guide

. All other related documents are also available online at 

http://supportforums.adtran.com

NetVanta 3458 Features and Specifications

Dual-slot, dual-Ethernet modular IP router 

Modular Network Interface: 56K/64K DDS, T1/FT1, T1/FT1 + DSX-1, Dual T1, E1/FE1, E1/FE1 + 
G.703, or ADSL (Annex A or Annex B), SHDSL (Annex A or Annex B), serial, or USB WWAN 

Modular IP access router for MPLS, Frame Relay, multilink Frame Relay, PPP, MLPPP, PPPoE, ATM, 
and HDLC networks 

Embedded eight port 10/100Base-T Ethernet switch

Switch ports can optionally be equipped to provide (802.3af) PoE

High-performance processor

Hardware encryption engine embedded 

On-board Flash memory

Expandable memory storage via a CompactFlash card slot on the front panel

Two integrated 10/100Base-T WAN/LAN ports 

ADTRAN Operating System (AOS) command line interface (CLI)

User-friendly, Web-based graphical user interface (GUI) 

Standards-based BGP, OSPF, RIP, static routing, and bridging protocols 

Integral stateful inspection firewall protects against denial of service (DoS) attempts   

Flash memory supports multiple images of AOS 

Interchangeable network interface modules (NIMs) 

Dial backup to any PPP-compliant device 

Analog modem, ISDN BRI U, or ISDN BRI S/T dial backup interface modules (DIMs) available 

500 ISsec VPN tunnels (software optional) with DES, 3DES, and AES encryption 

Compatible with ISsec VPN-equipped devices 

Quality of service (QoS) with class-based weighted fair queuing (CBWFQ), low latency queuing 
(LLQ), weighted fair queuing (WFQ), and DiffServ marking 

Built-in alert and logging mechanisms 

Network address translation (NAT/NAPT) and NAT Traversal version 2 

Summary of Contents for NetVanta 3200 series

Page 1: ...Network Interface Module Annex A 1200937E1 NetVanta SHDSL Network Interface Module Annex B 1202869E1 NetVanta ADSL Network Interface Module Annex A 1202889E1 NetVanta ADSL Network Interface Module An...

Page 2: ...blication Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use the software on the purchased ADTRAN...

Page 3: ...yright 2012 ADTRAN Inc 3 Conventions Notes provide additional useful information Cautions signify information that could prevent service interruption or damage to the equipment Warnings provide inform...

Page 4: ...cket outlet shall be installed near the equipment and shall be easily accessible If any of the following conditions occur unplug the product from the electrical outlet and replace the part or contact...

Page 5: ...unit contains no user serviceable parts 6 This equipment is designed to connect to the telephone network or premises wiring using an FCC compatible modular jack which is compliant with Part 68 and req...

Page 6: ...A EN 55022 Class A FCC Part 15 Class A EN 55022 Class A 1202872L1 Dual T1 NIM FCC Part 15 Class B EN 55022 Class B FCC Part 15 Class A EN 55022 Class A FCC Part 15 Class A EN 55022 Class A FCC Part 15...

Page 7: ...cables aux appareils num riques de Class A prescrites dans la norme sur le materiel brouilleur Appareils Num riques NMB 003 edictee par le ministre des Communications Toll Fraud Liability Be advised t...

Page 8: ...Service and Warranty NetVanta 3200 3300 3400 Series 8 Copyright 2012 ADTRAN Inc 61200860L1 34AB...

Page 9: ...NetVanta 3448 Features and Specifications 29 NetVanta 3448 Shipping Contents 30 NetVanta 3448 Front Panel Design 31 NetVanta 3448 Rear Panel Design 32 NetVanta 3450 32 NetVanta 3450 Features and Spec...

Page 10: ...ta 3448 NetVanta 3450 and NetVanta 3458 62 Wall Mounting NetVanta 3200 3300 3400 Series 63 Wall Mounting the NetVanta PoE Power Supply 67 Supplying Power to the Unit 69 Powering the NetVanta 3200 69 P...

Page 11: ...48 Figure 20 NetVanta Dual T1 NIM 49 Figure 21 NetVanta E1 FE1 NIM 50 Figure 22 NetVanta E1 FE1 G 703 NIM 51 Figure 23 NetVanta Serial NIM 52 Figure 24 NetVanta SHDSL NIM Annex A 53 Figure 25 NetVant...

Page 12: ...List of Figures NetVanta 3200 3300 3400 Series 12 Copyright 2012 ADTRAN Inc 61200860L1 34AB...

Page 13: ...ta 3205 DC Version Only 86 Table A 5 ADSL Connector Pinouts 86 Table A 6 WAN DDS Connector Pinouts 87 Table A 7 WAN T1 Connector Pinouts 87 Table A 8 WAN E1 Connector Pinouts 87 Table A 9 DSX 1 Connec...

Page 14: ...List of Tables NetVanta 3200 3300 3400 Series 14 Copyright 2012 ADTRAN Inc 61200860L1 34AB...

Page 15: ...ing Power to the Unit on page 69 Installing Dial Backup and Network Interface Modules on page 74 Using a USB Cellular Modem with the NetVanta USB WWAN NIM on page 76 Installing the NetVanta VPN Accele...

Page 16: ...ith ISsec VPN equipped devices IP encapsulation over Frame Relay RFC 1490 ADTRAN Operating System AOS command line interface CLI User friendly Web based graphical user interface GUI Standards based eB...

Page 17: ...l Backup and Network Interface Modules on page 74 for more details NetVanta 3200 Shipping Contents Each NetVanta 3200 unit is shipped in its own cardboard shipping carton Open each carton carefully an...

Page 18: ...t The SLOT 1 NET DBU option slot supports various plug in NIMs These option modules are described in the section Option Modules on page 41 10 100Base T Ethernet Interface and Activity LEDs The Etherne...

Page 19: ...or MPLS Frame Relay multilink Frame Relay PPP MLPPP PPPoE ATM and HDLC networks Integrated IP router with bridging Optional ISsec VPN supporting DES 3DES AES encryption IP encapsulation over Frame Rel...

Page 20: ...03 Serial V 35 X 21 EIA 530 SHDSL Annex A and Annex B ADSL Annex A and Annex B If needed an analog modem ISDN BRI U or ISDN BRI S T DIM can plug onto the NIM providing dial backup capability Refer to...

Page 21: ...e 85 provides pinouts Figure 4 NetVanta 3205 AC version Rear Panel Layout Figure 5 NetVanta 3205 DC version Rear Panel Layout NetVanta 3205 Rear Panel Interfaces and LEDs SLOT 1 NET DBU Option Slot Th...

Page 22: ...s NetVanta 3305 The NetVanta 3305 is a modular access router designed for cost effective branch office connectivity over MPLS Frame Relay multilink Frame Relay PPP MLPPP or Ethernet networks For VPN a...

Page 23: ...etwork management Integrated EIA 232 DCE configuration port DB 9 Optional dial backup ISDN BRI DIM ISDN S T DIM or analog modem DIM Front panel LEDs Size 17 25 inch W x 1 26 inch H x 7 75 inch D AC Po...

Page 24: ...owing items NetVanta 3305 base unit with attached mounting ears screws Quick start guide Detachable AC power cord NetVanta 3305 Front Panel Design The NetVanta 3305 front panel is shown below Front pa...

Page 25: ...rnational routers are shipped with a universal input lump in line supply with the appropriate cables All of the 1U high products have universal power supplies and are shipped with the appropriate cabl...

Page 26: ...anisms Network address translation NAT NAPT and NAT Traversal version 2 NAT compatible SIP ALG DHCP client server and relay XAUTH including RADIUS and RSA SecurID AAA support using local user database...

Page 27: ...equipment has been damaged in transit immediately file a claim with the carrier and contact ADTRAN Customer Service refer to the Support page on the ADTRAN website at http www adtran com support Dome...

Page 28: ...3430 rear panel is shown below with a module installed Appendix A on page 85 provides pinouts Figure 9 NetVanta 3430 1202820G1 Rear Panel Layout NetVanta 3430 Rear Panel Interfaces SLOT 1 NET DBU Opt...

Page 29: ...hernet modular IP router Modular Network Interface 56K 64K DDS T1 FT1 T1 FT1 DSX 1 Dual T1 E1 FE1 E1 FE1 G 703 ADSL Annex A or Annex B SHDSL Annex A or Annex B serial or USB WWAN High performance proc...

Page 30: ...interchangeable NIMs and DIMs The NIMs available for the NetVanta 3448 provide a variety of WAN connectivity options including the following 56K 64K DDS T1 FT1 T1 FT1 DSX 1 Dual T1 E1 FE1 E1 FE1 G 703...

Page 31: ...ion only NetVanta 3448 Front Panel Design The NetVanta 3448 front panel is shown below Front panel LED descriptions are given in Table 1 on page 40 In addition to the LEDs this front panel contains a...

Page 32: ...elf cannot be powered by this port 8 Switch Port Interfaces Ports 1 through 8 are RJ 45 connectors used to access the fully managed 10 100Base T Ethernet switch 10 100Base T Ethernet Interfaces The Et...

Page 33: ...tateful inspection firewall protects against denial of service DoS attempts Flash memory supports multiple images of AOS Interchangeable network interface modules NIMs Dial backup to any PPP compliant...

Page 34: ...g a USB cellular modem from the USB WWAN NIM NetVanta 3450 Shipping Contents Each NetVanta 3450 unit is shipped in its own cardboard shipping carton Open each carton carefully and avoid deep penetrati...

Page 35: ...to Installing a CompactFlash Card on page 80 NetVanta 3450 Rear Panel Design The NetVanta 3450 rear panel is shown below with a module installed Appendix A on page 85 provides pinouts Figure 13 NetVan...

Page 36: ...Dual slot dual Ethernet modular IP router Modular Network Interface 56K 64K DDS T1 FT1 T1 FT1 DSX 1 Dual T1 E1 FE1 E1 FE1 G 703 or ADSL Annex A or Annex B SHDSL Annex A or Annex B serial or USB WWAN M...

Page 37: ...nterchangeable NIMs and DIMs The NIMs available for the NetVanta 3458 provide a variety of WAN connectivity options including the following 56K 64K DDS T1 FT1 T1 FT1 DSX 1 Dual T1 E1 FE1 E1 FE1 G 703...

Page 38: ...panel LED descriptions are given in Table 1 on page 40 Figure 14 NetVanta 3458 Front Panel Layout CONSOLE Interface The CONSOLE interface is an EIA 232 serial port DCE that provides for local manageme...

Page 39: ...or PoE applications This port is active only if the NetVanta 3458 has been ordered with the PoE option Note that the NetVanta 3458 itself cannot be powered by this port 8 Switch Port Interfaces Ports...

Page 40: ...it is in test NET TD RD not present on all units Off There is no activity on the WAN or DBU port Green flashing There is activity on the WAN or DBU port LAN TD RD not present on all units Off There is...

Page 41: ...E1 on page 52 NetVanta SHDSL NIM Annex A P N 1200936E1 on page 53 NetVanta SHDSL NIM Annex B P N 1200937E1 on page 54 NetVanta ADSL NIM Annex A P N 1202869E1 on page 55 NetVanta ADSL NIM Annex B P N 1...

Page 42: ...foot RJ 45 to RJ 45 cable ADTRAN P N 3125M008 A NetVanta T1 FT1 DSX 1 NIM 1202863L1 Shipments of the T1 FT1 DSX 1 NIM include the following items T1 FT1 DSX 1 Network Interface Module Quick start guid...

Page 43: ...1202869E1 Shipments of the ADSL NIM Annex A include the following items ADSL Network Interface Module Quick start guide 7 foot RJ 11 to RJ 11 cable ADTRAN P N 3127014 NetVanta ADSL NIM Annex B 120288...

Page 44: ...clude the following items ISDN S T Dial Backup Interface Module Quick start guide 7 foot RJ 45 to RJ 11 cable ADTRAN P N 3125M007 A Option modules are intended to be serviced by qualified service pers...

Page 45: ...l DIM is required for dial backup applications Figure 16 NetVanta 56K 64K NIM Features and Specifications Operating Modes Dedicated DDS leased line DDS Interface Supported Standards AT T TR 62310 4 wi...

Page 46: ...core TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0...

Page 47: ...ANSI T1 403 Bellcore TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5...

Page 48: ...annelized multiples of 56 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assignment Programmable Connector RJ 48C DSX 1 Interface Line Interface DSX 1 p...

Page 49: ...ions Operating Modes Frame Relay multilink Frame Relay PPP MLPPP HDLC T1 Interface Supported Standards AT T TR 62411 AT T TR 65016 ANSI T1 403 Bellcore TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI...

Page 50: ...Supported Standards ITU G 703 ITU T G 704 CRC 4 ITU T G 823 ITU T G 797 Line Rate 2 048 Mbps 50 PPM Line Code AMI or HDB3 Framing FAS with optional CRC 4 FE1 Line Rate Channelized timeslot in multiple...

Page 51: ...TU T G 823 ITU T G 797 Line Rate 2 048 Mbps 50 PPM Line Code AMI or HDB3 Framing FAS with optional CRC 4 FE1 Line Rate Channelized timeslot in multiples of 64 kbps Receiver Sensitivity 30 dB Connector...

Page 52: ...is required for dial backup applications Figure 23 NetVanta Serial NIM Cable length for the Serial NIM should not exceed 25 feet SERIAL DBU Features and Specifications Operating Mode DTE only Serial I...

Page 53: ...2 pairs ITU T G 991 2 Line Rate 2 wire mode 192 to 2304 kbps in 64k increments Line Rate 4 wire mode 384 to 4608 kbps in 128k increments Payload ATM AAL5 Line Code TC PAM Connector RJ 45 Clock Source...

Page 54: ...irs ITU T G 991 2 Line Rate 2 wire mode 192 to 2304 kbps in 64k increments Line Rate 4 wire mode 384 to 4608 kbps in 128k increments Payload ATM AAL5 Line Code TC PAM Connector RJ 45 Clock Source CPE...

Page 55: ...er POTS Annex A Supported Standards ITU G 992 1 G dmt ITU G 992 2 G lite ITU G 992 3 ADSL2 G dmt bis ITU G 992 5 ADSL2 ANSI T1 413 Issue 2 Reach Extended ADSL READSL2 Connector RJ 1C 6 pin jack inner...

Page 56: ...cifications ADSL Interface ADSL over ISDN Annex B Supported Standards ITU G 992 1 G dmt Connector RJ 11C 6 pin jack inner pair ATM Multiple Protocol over AAL5 RFC 2684 PPP over ATM RFC 2364 PPP over E...

Page 57: ...e shipped with the NIM or online at http kb adtran com See Table A 13 on page 89 for the USB WWAN connector pinouts Figure 28 NetVanta USB WWAN NIM WWAN Features and Specifications USB Interface Suppo...

Page 58: ...r to Installing Dial Backup and Network Interface Modules on page 74 Features and Specifications Features ITU V 90 compliant Async Standards EMC see Electromagnetic Compatibility EMC Table on page 6 A...

Page 59: ...d Network Interface Modules on page 74 Features and Specifications Features Clear Channel and bonding mode 1 call protocols Network support for 64 kbps 1 B channel or 128 kbps 2 B channels D channel s...

Page 60: ...age 74 Features and Specifications Features Clear channel and bonding mode 1 call protocols Network support for 64 kbps 1 B channel or 128 kbps 2 B channels D channel switch compatibility with AT T 5E...

Page 61: ...ies are Ethernet cable Network cable module dependent DSX 1 cable T1 FT1 DSX 1 module only DBU cable dial backup functions require an optional DIM Phillips head screwdriver rack mounting applications...

Page 62: ...cts You must order the rackmount kit separately NetVanta 3430 3448 Series Rackmount Kit part number 1200827E1 If you have purchased P N 4200368L1 which includes the VPN Accelerator Card with the NetVa...

Page 63: ...arance between units 3 Have an assistant hold the unit in position as you install two mounting bolts through the unit s brackets and into the equipment rack using a 2 phillips head screwdriver 4 Proce...

Page 64: ...y Using sheetrock anchors may not provide sufficient long term stability 3 Install two 8 PAN head screws 1 inch or greater in length into the mounted board following these guidelines and referring to...

Page 65: ...ds to be mounted at or below eye level so that the LEDs are viewable Important Mount the chassis with LEDs facing to the side as shown in Figure 30 not facing up or down 3 Prepare the mounting surface...

Page 66: ...th wood screws Important Mounting to a stud ensures stability Using sheetrock anchors may not provide sufficient long term stability 4 Install two 6 PAN head screws 1 inch or greater in length into th...

Page 67: ...ach them to the chassis see Figure 32 2 Decide on a location for the unit Keep in mind that the unit needs to be mounted at or below eye level so that the LEDs are viewable Important Mount the chassis...

Page 68: ...nstall two 8 PAN head screws 1 inch or greater in length into the mounted board following these guidelines and referring to Figure 33 on page 68 Mark the exact positioning of the screws by using the k...

Page 69: ...12 VDC power supply for connecting to the proper power receptacles Figure 34 NetVanta 3200 Power Connector This unit shall be installed in accordance with Articles 300 and 400 of NEC NFPA 70 Maximum...

Page 70: ...ed with the shipment This unit shall be installed in accordance with Articles 300 and 400 of NEC NFPA 70 Power to the AC system must be from a grounded 100 to 250 VAC 50 60 Hz source Maximum recommend...

Page 71: ...C is designed to operate with a nominal operating voltage of 48 VDC or 24 VDC and a minimum operating voltage of 20 VDC The NetVanta 3205 DC will not be damaged by any steady state voltage between 20...

Page 72: ...onding and grounding environment It must NOT be utilized in a DC I isolated bonding and grounding environment To Earth Ground 24 48V 1A NetVanta 3205 DC Power Connector AC In 48 VDC Power Supply AC In...

Page 73: ...erminal of the 24 VDC power source to the positive terminal of the NetVanta 3205 DC power connector 4 Connect the ground terminal of the NetVanta 3205 DC power connector to Earth ground For 48 VDC ope...

Page 74: ...removing or installing a module Improper installation may result in damage to the modules Instructions for Installing the DIMs Step Action 1 Remove power from the unit 2 If the NIM is already in the...

Page 75: ...or Installing the NIMs Step Action 1 Remove power from the unit 2 Remove the cover from the option slot 3 Slide the option module into the option slot until the module is firmly seated against the cha...

Page 76: ...installation may result in damage to the modules Instructions for Installing a USB Cellular Modem in the USB WWAN NIM Step Action 1 Remove power from the base unit 2 Remove the cover from the base uni...

Page 77: ...N Accelerator Card Installation The AOS Enhanced Feature Pack software is required to take advantage of the VPN acceleration features of this card The Accelerator Card is intended to be installed only...

Page 78: ...unting brackets 3 Using a 3 16 inch hex driver remove the two jack screws located on either side of the DB 9 port if applicable 4 Carefully lift and remove the unit s cover to expose the circuit board...

Page 79: ...00 Series Unit Installation 61200860L1 34AB Copyright 2012 ADTRAN Inc 79 Figure 39 SODIMM Installation Keyed Slots Figure 40 SODIMM Installation Applying Pressure Figure 41 SODIMM Installation Rotatin...

Page 80: ...ctions when installing a card Figure 42 CompactFlash Card Installation The CompactFlash card is hot swappable and can be inserted or removed while power is applied to the unit Instructions for Install...

Page 81: ...and secure the two standoffs supplied with the NetVanta Octal PoE module into the two holes from which you removed the PC board mounting screws 6 Carefully align the 34 pin receptacle on the Octal PoE...

Page 82: ...now ready to be configured and connected to the network For information on configuration for a specific application refer to the configuration guides provided on the ADTRAN Support Community For deta...

Page 83: ...switch ports only 2 TX2 Transmit Negative PoE negative rail switch ports only 3 RX1 Receive Positive PoE negative rail switch ports only 4 5 Unused 6 RX2 Receive Negative PoE negative rail switch port...

Page 84: ...al Ready input 5 SG Signal Ground 6 DSR Data Set Ready output Tied to pin 1 7 RTS Request to Send input 8 CTS Clear to Send output Tied to pin 1 9 RI Ring Indicate output Connection directly to an ext...

Page 85: ...Tip 8 R Receive data from the network Ring Table A 7 WAN T1 Connector Pinouts Pin Name Description 1 R1 Receive data from the network Ring 1 2 T1 Receive data from the network Tip 1 3 Unused 4 R Tran...

Page 86: ...1 Receive data from the DTE Ring 1 5 T1 Receive data from the DTE Tip 1 6 8 Unused Table A 10 G 703 Connector Pinouts Pin Name Description 1 R Transmit data toward the DTE Ring 2 T Transmit data towar...

Page 87: ...34AB Copyright 2012 ADTRAN Inc 89 Table A 12 WAN ADSL Connector Pinouts Pin Name Description 1 2 Unused 3 R ADSL Ring 4 T ADSL Tip 5 6 Unused Table A 13 USB WWAN Connector Pinouts Pin Name Descriptio...

Page 88: ...21 Pin EIA 530 Pin Name 1 P 2 2 TD_A 2 U N A 24 ETC_A 3 Y N A 15 TCLK_A 4 V 6 17 RCLK_A 5 R 4 3 RD_A 6 F N A 8 DCD_A 7 H N A 20 DTR_A 8 C 3 4 RTS_A 9 N A 10 19 RTS_B V 11 only 10 N A 12 13 CTS_B V 11...

Page 89: ...l DIM is required for dial backup applications Table A 15 Analog Modem and ISDN BRI DBU Connector Pinouts Pin Name Description 1 3 Unused 4 R Network Ring 5 T Network Tip 6 8 Unused Table A 16 ISDN S...

Page 90: ...Appendix A Connector Pin Definitions NetVanta 3200 3300 3400 Series 92 Copyright 2012 ADTRAN Inc 61200860L1 34AB...