Quick Start Guide, 61700601G2-13E, March 2015

3

4.

Select 

Apply

. If PPP or PPPoE is selected as the 

Interface Mode

, you will be taken to the 

PPP

 page after selecting 

Apply

. Here you will need to select the type of authentication 

needed, authentication passwords, and the 

Address Type

. In most cases, you will want the 

Address Type

 to be 

Negotiated

. Select 

Apply

 when all the information is complete.

A

CCESS

 

THE

 CLI

If needed, you can access the CLI from a Telnet or SSH client. To access the CLI using a Telnet 
or SSH client, follow these steps:
1.

Connect the unit to your PC, using an Ethernet cable connected to one of the Ethernet ports 
(

Ethernet 1

2

3

, or 

4

) on the rear of the unit. 

2.

Use a Telnet or SSH client to connect to 

10.10.10.1

. If you have changed your unit's IP 

address, you will need to enter that address.

3.

For SSH, log into the unit using the default login (

admin

) and password (

password

). For 

Telnet, only the default password (

password

) is required.

4.

Enter 

enable

 at the 

>

 prompt and enter the enable password when prompted. The default 

password is 

password

.

C

HANGE

 L

OGIN

 P

ASSWORDS

1.

To modify the user accounts and passwords, from the 

(config)# 

prompt, enter the command 

username

 

<username>

 

password

 

<password>

 to modify current user accounts or create a 

new one.

2.

To modify the Enable mode password, from the 

(config)# 

prompt, enter the command 

enable password

 

<password>

.

3.

To modify the Telnet password, from the 

(config)# 

prompt, enter the command 

line telnet 0 

4

 and then press 

<Enter>

. Enter the command 

password

 

<password>

4.

Enter 

do write

 to save the current configuration.

F

ACTORY

 D

EFAULT

 S

WITCH

If the factory default switch (shown in the illustration above) is pressed during bootup (while 
the STAT LED is flashing green), the unit will stay in bootstrap mode (the STAT LED will turn 
solid amber when the unit is in bootstrap mode). Since the unit has no serial port, Telnet has 
been built into the boot code. The default IP address is 

10.10.10.1

.

If the factory default switch is pressed and held for 5 seconds after boot, the switch ports 
1 through 4 on the NetVanta 3100 Series routers will default to 

10.10.10.1

 and all firewall 

access policies will be removed from that interface. 

1

2

3

4

ADSL

1

0

Default

Switch

If the factory default switch is pressed and held for approximately 70 seconds, a default 
configuration will overwrite your existing configuration and reboot the unit. When the default 
configuration is being applied the STAT, WAN, INET, and VPN LEDs will cycle. At this point 
the default switch can be released.

For more information on restoring factory defaults, refer to the guide 

Restoring an AOS Device to 

Factory Default

 available online at 

https://supportforums.adtran.com

.

To factory default the unit, the default switch must be pressed WHILE the 

STAT

 light on the front of the unit is solid green. Do not press the default 

switch BEFORE the 

STAT

 light is solid green, as this will cause boot to be 

missed.

F

RONT

 P

ANEL

 LED

S

LED

Color

Indication

STATUS 
(

STAT

)

Green (flashing)

The unit is powering up. On power-up, the 

STAT

 LED flashes 

rapidly for five seconds.

Green (solid)

The power is on and self-test passed.

Red (solid)

The power is on, but the self-test failed or the boot mode (if 
applicable) code could not be booted.

Amber (solid)

The unit is in bootstrap mode.

ETH1

Off

The port is administratively disabled or does not have link.

(3120 only)

Green (solid)

The port is enabled and the link is up.

Amber (flashing)

The port has activity (transmit or receive).

WAN

Off

The interface is administratively down.

(3130 only)

Green (solid)

The link is up and everything is operational.

Red (solid)

An alarm condition is occurring on the WAN interface, or 
there is a self-test failure.

Amber (solid)

The unit is in test.

VPN

Off

No encrypted traffic.

On

Encrypted traffic present.

INET

Green (solid)

The unit has a fixed IP address, or has obtained an IP 
address through DHCP.

Green (flashing)

Traffic is present on the ADSL WAN interface (3130 only).

Red (solid)

The unit failed to obtain an IP address through IPCP or 
DHCP (3130 only).

Red (flashing)

The DHCP client is rebooting (3120 only).

Amber (flashing)

No IP address has been obtained through DHCP (3120 
only).

SWITCH

 (

1

  Off

The port is administratively disabled or does not have link.

through 

4

)

Green (solid)

The port is enabled and the link is up.

Amber (flashing)

The port has activity (transmit or receive).