Option Modules
NetVanta 1000 Series Switch Hardware Installation Guide
26
© 2004 ADTRAN, Inc.
61200500L1-34C
Network Interface Modules
NetVanta 56K/64K NIM (P/N 1200861L1)
The 56K/64K NIM (shown in Figure 7) provides a WAN interface for the NetVanta. This module provides
a single 56K or 64K DDS network interface. Refer to Table A-5 on page 43 for the WAN-DDS connector
pinout, and Table A-11 on page 46 for the DBU connector pinout. An optional DIM is required for dial
backup applications.
Figure 7. NetVanta 56K/64K NIM
Features and Specifications
Operating Modes
•
Dedicated DDS (leased line)
DDS Interface
•
RJ-48C
•
4-wire, full duplex
•
-45 dB receiver sensitivity all rates
•
Data Rates: 56K, 64K, and Auto
Clock Source
•
Network
•
Internal
Diagnostics
•
CSU and DSU Loopbacks
Relevant Requirements/Standards
•
EMC - see
(EMC) Table for the NetVanta
1224STR/1224R
•
ACTA/FCC Part 68
•
Industry Canada CS03
•
UL and CUL
•
AT&T TR 62310
Environmental
•
Operating Temperature: 0 °C to 50 °C
•
Storage Temperature: -40 °C to 85 °C
•
Relative Humidity: Up to 95%
non-condensing
Physical
•
Dimensions: 4.25" x 2.75"