2

61190852L2-5, Issue 3

61190852L2-5C

• Insert E220/DDM+ form factor

P/N 1190852L23

• Insert E220/Soneplex form factor

P/N 1190852L24

NOTE

The installation kit and adapter inserts described
here are not compatible with previous kit and
adapter assemblies.

Description

The HDSL CO Installation Kit simulates the operation
of the central office end of an HDSL circuit (with
installed CO line unit).

Make-or-break jacks and signal jacks in each
installation kit provide access to the HDSL circuit’s
loop 1 and loop 2 signals. Inserting a test cable into a
jack breaks the HDSL circuit at that point and delivers
the signal out of the jack.

 The jacks can be used to insert an HDSL installation
kit into an HDSL circuit at different points (such as
the central office end or remote end) in order to test
circuit or line unit operation.

The jacks can also be used to connect HDSL
installation kits together to simulate an HDSL circuit’s
signal path.  A fully operational HDSL circuit can be
created by connecting a CO Installation Kit to a

remote installation kit, and installing HDSL line units.
See 

Figure 2

 for an HDSL circuit simulation.  To

simulate an HDSL circuit with a repeater, push IN the
repeater selection switch on the remote unit.

2. OPERATION

After unpacking the unit, inspect it for damage.  If
damage is noted, file a claim with the carrier, then
notify ADTRAN. See 

Warranty and Customer

Service

.

The CO Installation Kit is shipped complete with the
CO shelf, softcase, power cord, and dual bantam to
alligator clip cable.

Front Panel Features

The HDSL CO Installation Kit front panel features a
CO unit slot, two dual-bantam jacks, and two ground
lugs for ESD ground and earth ground.  The CO unit
slot accepts an HDSL CO line unit.  The CO LP1/LP2
signal jacks provide access to the CO line unit’s
(HTU-C) output signals to the remote end.  These
signals are the loop 1 and loop 2 signals that drive the
HDSL circuit.  The DSX TX and RX jacks provide
access to the DSX signals on a CO line unit installed
in the CO Installation Kit.  These jacks can be used in
addition to DSX jacks on the front panel of the
HTU-C line unit.  TX is an input jack and RX is an
output jack.  See 

Figure 3

 for a diagram of front panel

features.

Figure 2.  HDSL Circuit Simulation

CO

DSX Access

Jacks

Remote

DS1 Access

Jacks

CO

LP1/LP2

Signal Jacks

Repeater CO

Side LP1/LP2
Signal Jacks

Repeater 

In/Out 

Switch

852

Shelf

CO

Bay

851

Shelf

Repeater

Bay

851

Shelf

Remote

Bay

Repeater

Remote Side

LP1/LP2

Make/Break

Jack

Remote

LP1/LP2

Make/Break

Jack

HDSL 852 CO Power Shelf

HDSL 851 REPEATER/Remote Shelf

Summary of Contents for HDSL 852

Page 1: ...DM Plus and Soneplex adapter inserts Bantam to alligator connections Versatile protective carrying case Adapter Inserts Separately purchased adapter inserts configure the E220 form factor to accomodate the following mechanics Insert E220 3192 P N 1190852L22 FIGURES Figure 1 HDSL 852 CO Installation Shelf 1 Figure 2 HDSL Circuit Simulation 2 Figure 3 Front Panel Features 3 Figure 4 Rear Panel Featu...

Page 2: ...repeater selection switch on the remote unit 2 OPERATION After unpacking the unit inspect it for damage If damage is noted file a claim with the carrier then notify ADTRAN See Warranty and Customer Service The CO Installation Kit is shipped complete with the CO shelf softcase power cord and dual bantam to alligator clip cable Front Panel Features The HDSL CO Installation Kit front panel features a...

Page 3: ...Office Powering Shelf Customer Equipment or NIU HDSL Circuit CAUTION RISK OF ELECTRICAL SHOCK MAXIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TELECOM CIRCUITS 1190851L2 HDSL 851 REPEATER REMOTE ESD GND RPTR C O CABLE PAIRS RPTR TO REMOTE CABLE PAIRS LP1 LP2 LP1 LP2 REMOTE CABLE PAIRS DS1 LP1 LP2 RX TX RPTR IN OUT CAUTION RISK OF ELECTRICAL SHOCK MAXIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TE...

Page 4: ... pairs that form the HDSL circuit The cables are attached depending on the installation as follows For a single pair HDSL installation use a test cable with a single bantam end and two alligator clips Insert the cable s bantam end in the LP1 signal jack and attach each alligator clip to one of the wires in the twisted pair For a two pair HDSL installation use a test cable with a dual bantam end an...

Page 5: ...e Units 2 Verify that the other required line units are available for the test see Table 1 The required line unit s can either be installed in another HDSL Installation Kit or in an HDSL circuit NOTE Verifythattherequiredlineunitsareoperational before proceeding 3 Install patch cables to make the necessary connections between the line unit being tested and the required line units Figure 7 Testing ...

Page 6: ...2 LP1 LP2 Customer Equipment HDSL Circuit CAUTION RISK OF ELECTRICAL SHOCK MAXIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TELECOM CIRCUITS 1190851L2 HDSL 851 REPEATER RE MOTE ESD GND RPTR C O CABLE PAIRS RPTR TO REMOTE CABLE PAIRS LP1 LP2 LP1 LP2 REMOTE CABLE PAIRS DS1 LP1 LP2 RX TX RPTR IN OUT T1 BERT Tester CAUTION RISK OF ELECTRICAL SHOCK MAXIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TELEC...

Page 7: ...XIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TELECOM CIRCUITS 1190852L2 HDSL 852 CO POWER REMOTE LP1 LP2 DS1 TX RX ESD GND s t n e m e r i u q e R r e w o P m e t s y S r e w o P c a V 5 1 1 d e d n u o r G x a M A 5 0 z H 0 6 0 5 0 1 l a t n e m o r i v n E e r u t a r e p m e t g n i t a r e p O e r u t a r e p m e t e g a r o t S C 0 5 o t C º 0 F 2 2 1 o t F º 2 3 C 0 7 o t C º 0 4 F 8 5 1 o...

Page 8: ...and Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Pre sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Retur...

Reviews: