8

Section 61250110L1-5, Issue 4

61250110L1-5D

From Previous

Page

DSL

 Loop Sync & 

Act Status

DSL

 Carrier Sync & 

Act Status

DSL

 BER

T

 T

est Status

DSX Alarm 

Status

3. Status

4. T

est

1. DSX Loopbacks

1. Current Loopbacks

6. Remote Payload Loopback

5. Remote Line Loopback

4. Payload Loopback

3. Line Loopback

2. Local Loopback

1. None

2. ISDN Loopbacks

and BER

T

 T

esting

10. DSL

 10

1. DSL

 1

2. DSL

 2

3. DSL3

4. DSL

 4

5. DSL

 5

6. DSL

 6

7. DSL

 7

8. DSL

 8

9. DSL

 9

3. Bilateral

Loopback

1. On

2. Of

f

5. Performance

1. DSX Performance

Active Alarm 

Status:

T1 Performance

Near end ES and SES data (24-hour and 15-minute registers)

Far end ES and SES data (24-hour and 15-minute registers)

Active Alarm 

Status:

DSL

 Performance in customer (or network) direction

Current hourly BE, ES, SES data

Current daily ES, SES, data

Previous hourly BE, ES (8 hours), SES data

Previous daily ES, SES data

2. ISDN Performance

E220 HD-10 Menu Structure, Page 2 of 2

  

T

est Status:

 T

est Commands:

T

est

Error Bits

T

otal Bits

BER

Lost Sync Count

Enter 1 through 7 for 

ADR 1 through 7

A

 = 2B+D

B = B1

C = B2

F = Force polling

I  = Insert one bit error

L

 = Loop 

TX

P

 = Loopback

R = Carrier 

TX

S = Start/Stop 

T

est

0 = Reset counters (0 = zero)

N = NT1

NOTE:

BE = Block Error

ES = Errored Second

SES = Severely Errored 

           Second

Pass / Fail Status:

ROM T

est

RAM T

est

EEPROM T

est

T1 Chip 

T

est 

DSL1-10 T

est

4. Self 

T

est Results

Figure 4.  HD-10 Provisioning Menu Part 2

Summary of Contents for HD-10 BRI MUX

Page 1: ... NWT 000829 Provides T1 interface compatibility with DSX 1 and DS1 signals Supports superframe and extended superframe formats Supports AMI and B8ZS line coding Provides DB 9 terminal interface for provisioning testing and performance monitoring Provides bilateral loopback capability activated from faceplate switch Provides Local Loop External and CAU timing options Provides an alarm relay and ala...

Page 2: ...r seats firmly into the backplane A similar process applies to the standalone housing CAUTION This product is intended for installation in Restricted Access Locations only and is intended to be installed in equipment with a Type B or E installation code C A U T I O N SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY HANDLING PRECAUTIONS REQUIRED Connections All input and output to the HD ...

Page 3: ...e with any D4 channel bank that is compliant with TR NWT 000397 and configured for D4 terminal with D4 counting The 10 DSL mode is compatible with any channel bank that supports the ADTRAN 4 1 TDM format such as the ADTRAN BR1 10 Channel Bank The HD 10 does not support D1D counting SLC Mode 1 or SLC Mode 3 LED Indication The HD 10 faceplate has 13 LEDs to indicate the operational status of the uni...

Page 4: ...i f n o c n e h W t n e r r u c g n i l a e s s l o r t n o c 5 4 W S e d o m T L U L n I M D T e c r u o S e c i f f O m e d n a T r o f d e r u g i f n o c n e h W d e d i v o r p e b t s u m t n e r r u c g n i l a e s J D A d e l b a s i d e b d l u o h s d n a d e r i u q e r t o n s i t n e r r u c g n i l a e s e b d l u o h s s e n o t p u e k a w c i d o i r e P e n o t p u e k a w c i d ...

Page 5: ... Y g n i h s a l f w o l l e Y e v i t c a s k c a b p o o l 1 T o n l a m r o N e v i t c a k c a b p o o l 1 T l a r e t a l i b l a c o L g n i d n a m m o C r o e d o m F S E k c a b p o o l d e t a i t i n i e t o m e r n i e c a f r e t n i 1 X S D r o 1 S D e d o m F S E e c a f r e t n i 1 X S D r o 1 S D e h t r e v o t i n u r e h t o n a o t k c a b p o o l e t o m e r a L S D 0 1 1 f f...

Page 6: ...roceed with the desired action To make a selection press the number on the keyboard for the desired category then press enter Specific screen displays are on the pages following the menu tree and as listed below Main Menu below DSL Test Menu Testing for DSL 1 DSX Performance DSL Performance in CUSTOMER Direction DSX Performance Screen The DSX Performance Screen records error data from both the loc...

Page 7: ... ft 5 533 655 ft 6 7 5 dB 7 15 dB 8 22 5 dB 1 ESF 2 SF 1 B8ZS 2 AMI 5 Framing 6 Line Code 1 OFF 2 ON 7 U TMG 2 Provisioning 1 DSX Provisioning 2 ISDN Provisioning 1 Operating Mode 2 Sealing Current 3 Tandem Feature 1 LULT 2 LUNT 1 Off 2 On 1 Off 2 On 4 Individual DSL Settings 1 Change Current DSL 1 DSL 1 2 DSL 2 3 DSL 3 4 DSL 4 5 DSL 5 6 DSL 6 7 DSL 7 8 DSL 8 9 DSL 9 10 DSL 10 2 ZBS 3 Service 1 Of...

Page 8: ... minute registers Far end ES and SES data 24 hour and 15 minute registers Active Alarm Status DSL Performance in customer or network direction Current hourly BE ES SES data Current daily ES SES data Previous hourly BE ES 8 hours SES data Previous daily ES SES data 2 ISDN Performance E220 HD 10 Menu Structure Page 2 of 2 Test Status Test Commands Test Error Bits Total Bits BER Lost Sync Count Enter...

Page 9: ... NT1 0 0 0 0000E 00 IDLE 7 DSL 7 B1 NT1 0 0 0 0000E 00 IDLE 8 DSL 8 B1 NT1 0 0 0 0000E 00 IDLE 9 DSL 9 B1 NT1 0 0 0 0000E 00 IDLE 10 DSL 10 B1 NT1 0 0 0 0000E 00 IDLE Selection System Help Screen Adtran HD 10 ISDN BRI Mux Active Alarm None Terminal baud rate 9600 ISDN E220 HD 10 BRI Mux Testing for DSL 1 Test NO TEST ACTIVE Selected B1 loopback to NT1 Enter 1 7 for ADR 1 7 N NT1 Error bits 0 A 2D ...

Page 10: ... 0 0 0 0 0 0 0 0 0 Hour 6 ES 0 0 0 0 0 0 0 0 0 0 Hour 7 ES 0 0 0 0 0 0 0 0 0 0 Hour 8 ES 0 0 0 0 0 0 0 0 0 0 ENTER show NETWORK Direction System Help Screen e c n a m r o f r e P X S D s r e t s i g e r r u o h 4 2 s r e t s i g e r e t u n i m 5 1 e t a d S E S E S e m i t S E S E S e m i t S E S E S e m i t S E S E S R A E N D N E A T A D w o n 0 0 0 0 0 0 0 0 0 0 w o n 0 0 0 0 0 0 0 0 2 0 0 4 h...

Page 11: ...oopback bridges the T1 line across the receive pair to the transmit pair isolating the bank from the T1 line This allows for internal bank testing and individual card testing and provides a baseline for T1 line testing To initiate a local loopback navigate the menu as follows TEST DSX LOOPBACKS CURRENT LOOPBACK Then select LOCAL LOOPBACK to activate the desired test The HD 10 will return to the pr...

Page 12: ...an also activate a loopback in a downstream device An onboard 2047 pattern generator and error checker allow all 10 circuits of the HD 10 to be tested simultaneously The loopback test using the internal pattern generator is controlled via the faceplate DB 9 interface ISDN Loopback and BERT Testing Network loopback in the customer direction can be initiated from the DB 9 interface The 2047 pattern ...

Page 13: ...vigate the menu as follows PERFORMANCE DSX PERFORMANCE The DSX Performance screen provides the following PM History in both the Near End and Far End Directions Errored Second and Severely Errored Second data 24 Hour and 15 Minute Registers To see the local Performance Monitoring of all 10 ISDN DSLs navigate through the menu as follows PERFORMANCE ISDN PERFORMANCE The ISDN Performance screen provid...

Page 14: ...u t a t s L S D l a c i n a h c e M e z i S t h g i e W g n i t n u o M g n i t n u o m l a t n o z i r o h h g i h 8 3 1 x p e e d 2 1 0 1 x e d i w 2 1 5 z o 6 3 1 s b l 5 8 0 g n i s u o h e n o l a d n a t s r o f l e h s 0 1 D H s e d o C n o i t a r u g i f n o C C P e d o C r e w o P C T e d o C s n o i t a c i n u m m o c e l e T C I e d o C n o i t a l l a t s n I C T U O F N I X T U O X ...