Chapter 4. Troubleshooting
61200176L3-1
Express 4110/4120 User Manual
4-5
7.
If the Loop Status in the Express 4110/4120 Status Menu continuously
reads Register SPID #2, the Express 4110/4120 has completely initial-
ized the first phone number but is unable to establish logical layer 3 for
the second phone number. The problem is in one or both of the follow-
ing places:
•
The Express 4110/4120 software setup
•
The telephone service provider’s software setup
To isolate the problem, perform the following procedure:
A. Ensure the line is multipoint with two phone numbers.
B. Ensure that the Express 4110/4120 is set up with the correct SPID
and LDN. For example:
SPID1 = 20572270460101
SPID2 = 20572270470101
LDN 1 = 7227046
LDN 2 = 7227047
C. Try swapping SPID1 with SPID2 and LDN1 with LDN2. Deter-
mine if the problem is with the second phone number or the quan-
tity of phone numbers.
D. If possible, try another piece of functioning ISDN equipment with
a U-interface on the line.
E. With the Express 4110/4120 connected to the line and powered
up, talk to your service provider’s repair group and tell them you
have an ISDN basic rate line that appears physically okay but is
unable to register its SPIDs. Ask them to check the line transla-
tion, ensure the line supports dynamic TEI allocation, and verify
the SPIDs. Tell them that you have an NT1 and terminal adapter
device connected to the line.
Summary of Contents for Express 4110
Page 10: ......
Page 24: ...List of Tables xiv Express 4110 4120 User Manual 61200176L3 1...
Page 56: ...Chapter 2 Installation 2 6 Express 4110 4120 User Manual 61200176L3 1...
Page 146: ...Chapter 5 Specifications 5 4 Express 4110 4120 User Manual 61200176L3 1...
Page 172: ...Appendix B Log Messages B 22 Express 4110 4120 User Manual 61200176L3 1...
Page 176: ...Appendix C SNMP C 4 Express 4110 4120 User Manual 61200176L3 1...
Page 194: ...Acronyms Acronyms 4 Express 4110 4120 User Manual 61200176L3 1...
Page 204: ...Index Index 10 Express 4110 4120 User Manual 61200176L3 1...