61230001E1-22C
3
M
ENU
T
REE
1. Unit Information
Main Menu
2. Provisioning
3. Status
1. NT
2. L
T
1. 2-Wire
2. 4-Wire
0. Disabled
1-15. Alarm
Threshold
0. Disabled
1-127. Alarm
Threshold
0. Disabled
1-900. Seconds
2. Permanent On
3. Sync Mode
1. Permanent Of
f
1. From DCE,
TC (Circuit 1
1
4)
2. From DTE, ETC (Circuit 1
1
3)
1. Internal Clock
2. Nx64 ETC(1
1
3)/X
3. G.703 Rx Clock
0. Disabled
1-900. Seconds
1-65535. Seconds
00h to FFh
1. Unit Options
3. G.703 Options
1. Unit Mode
2. Cross-Connect Map
3. Clock Source
4. Circuit ID
5. Date and
T
ime
6. Restore Factory Defaults
7. Upgrade Firmware
8. Local Management
9. Change Password
1. ES 15-Minute
Alarm
Threshold
2. SES 15-Minute
Alarm
Threshold
3. UAS 15-Minute
Alarm
Threshold
0. Disabled
1-65535. Seconds
4. CVC 15-Minute
Alarm
Threshold
5. LOSWS 15-Minute
Alarm
Threshold
6. OS 15-Minute
Alarm
Threshold
0 to 255 = Delay in ms
2. SHDSL
Options
1. ISDN-PRA
V3
2. G.704 CRC-4 Multiframing
3. T
imeslot
Idle
Pattern
4. Spare Bits Insertion to Span
5. Spare Bits Pattern to Span
6. Spare Bits Insertion
7. Spare Bits Pattern
8. RAI Generation
9. E-bit Generation
10. ES 15-Minute
Alarm
Threshold
1
1
. SES 15-Minute
Alarm
Threshold
12. UAS 15 Minute
Alarm
Threshold
13. CVC 15-Minute
Alarm
Threshold
4. Nx64K Options
4. SHDSL
Rx Clock
1. Disabled
2. Enabled
* 2-wire mode: 192 kbps to 2.304 Mbps (N x 64 kbps, where N=3 to 36)
4-wire mode: 384 kbps to 4.608 Mbps (N x 64 kbps, where N=even numbers, 6 to 72)
4. T
est
5. Performance History
5. G.703 BER
T
4. G.703 Local Loopback
7. Nx64k Local Loopback
6. G.703 Services
8. Nx64k Remote Inband Loopback
9. Nx64k BER
T
1. SHDSL
Port
2. G.703 Port
3. Reset
All
7. T
erminal
Mode
Local Management
Remote V
irtual
T
erminal Management
3. SHDSL
BER
T
1. Dual Sided
2. Customer
T
ransparent
3. Customer Non-T
ransparent
4. Network
T
ransparent
5. Network Non-T
ransparent
1. AL
T
2. 2047
3. 2E15-1
4. QRSS
5. T
est
Options
1. Permanent Of
f
2. DTE Driven
1. L
T
U
2. NTU
1. Interface Mode
2. Payload Rate (kbps) *
3. SNR Margin
Alarm
Threshold (dB)
4. Loop
Attenuation
Alarm
Threshold (dB)
5. Outage
Auto-Retrain
6. PM
Thresholds
1. Disabled
2. Enabled
0. Disabled
1-900. Seconds
1. Disabled
2. Enabled
1. Disabled
2. Enabled
00h to FFh
1. Disabled
2. Enabled
00h to FFh
1. Disabled
2. Enabled
0. Disabled
1. Interface
T
ype
Auto Detection
2. Interface
T
ype Manual Select
3. Inactivity
Alarm Delay (Secs)
4.
Tx Clock Source
5.
Tx Clock Polarity
6. X.21 C Mode
7. X.21 I Mode
8. V
.35/V
.36 R
TS (Circuit 105)
9. V
.35/V
.36 R
TS (Circuit 106)
10. V
.35/V
.36 R
TS to CTS Delay (ms)
1
1
. V
.35/V
.36 DSR (Circuit 107)
12. V
.35/V
.36 DTR (Circuit 108/2)
13. CVC 15-Minute
Alarm
Threshold
1. Disabled
2. Enabled
0. Disabled
1-100. Alarm
Threshold
1. Permanent On
2. DTE Driven
1. X.21
2. V
.35
3. V
.36
1. Normal
2. Inverted
3. Auto
1. Permanent On
2. Sync Mode
1. Permanent On
2. DTE Driven
1. Permanent Of
f
2. Permanent On
3. R
TS Driven
1. Permanent Of
f
2. Permanent On
1. Permanent On
2. DTE Driven
1. Loopback
T
ypes
2. Inband Loopback Options
3. Loopback
T
imeout (Min)
4. BER
T
Pattern
5. BER
T
Pattern Polarity
6. Pushbuttons (All)
7. SHDSL
Port Select Pushbuttons
8. V
.35/V
.36 RL
(Circuit 140)
9. V
.35/V
.36 LL
(Circuit 141)
10. V
.35/V
.36
TI (Circuit 142)
0. Disabled
1-199.
T
ime Out in Minutes
1. In-band Loopback Protocol
2. G.703 Services In-band Pattern Detection
3. Nx64k In-band Pattern Detection
1. Dual Sided
2. T
ransparent
3. Nontransparent
1. PN127
2. V
.54
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Normal
2. Inverted
1. Disabled
2. Enabled
1. Permanent Of
f
2. T
e
st
Driven
1. SHDSL
Port
2. G.703 Port
3. G.703 Services
4. Nx64K Port
5. Reset
All Status
1. SHDSL
Local Loopback
2. SHDSL
Remote Loopback
2. Remote Inband Loopback
3. BER
T
1. Local Loopback
6. TSCAN
1. Restart Bad Splice Detector
2. 24 Hour Counts