ADTRAN 6540 Description Download Page 2

2

61230001E1-22C

S

PECIFICATIONS

Specifications for the 6540 are as follows:

Electrical

o

Operating Voltage: 100 – 240 VAC @ 50/60 Hz

o

Typical Current and Power Consumption: 
95 mA RMS, 5.5 W @ 115 VAC 60Hz,
60 mA RMS, 5.3 W @ 220 - 240 VAC 50Hz

o

Maximum Current Draw: 110 mA RMS @ 100 – 240 VAC

o

Maximum Power Consumption: 5.6 watts @ 100 VAC

Environmental

o

Operational Temperature Range: –5°C to +55°C

o

Storage Temperature Range: –40°C to +85°C

o

Relative Humidity: up to 95%, noncondensing

Physical

o

Height: 2.215 inches (5.63 cm)

o

Width: 9.25 inches (23.5 cm)

o

Depth: 6.625 inches (16.8 cm)

o

Weight: Less than 1 pound (0.45 kg)

I

NDUSTRY

 S

TANDARDS

 C

OMPLIANCE

The SHDSL 2-Wire/4-Wire NTU interfaces adhere to these 
industry standards, either partially or in full: 

SHDSL: ITU-T G.991.2 (12/03 and 2003 amendments) and 
G.994.1 (05/03)

G.703: ITU-T G.703 (10/98), G.704 (10/98), G.706 (4/91), G.732 
(11/88), G.775 (10/98), G.784 (1/94), G.797 (3/96), G.821 (8/
96), G.823 (03/93), and G.826 (2/99)

Nx64K: ITU-T X.21 (09/92), V.35 (10/84), and V.36 (11/88); 
and ISO 2593 (1984), 4903 (1991), and 4902 (1980)

S

AFETY

 

AND

 R

EGULATORY

 C

OMPLIANCE

Refer to the

 

Safety and Regulatory Compliance Notice for this 

product (P/N 61230001E1-17) for detailed safety and regulatory 
information.
Consultez l'avis sur la sécurité et la conformité à la réglemen-
tation pour ce produit (6123001E1-17) pour obtenir des renseigne-
ments détaillés sur la sécurité et la réglementation.
Ausführliche Sicherheits- und regulatorische Informationen sind 
in der Konformitätserklärung zur Sicherheit und Einhaltung von 
Normen zu diesem Produkt (6123001E1-17) aufgeführt.

P

USH

 

BUTTONS

M

AINTENANCE

The 6540 does not require routine hardware maintenance for 
normal operation. Do not attempt repairs in the field. Repair 
services may be obtained by returning the defective unit to 
ADTRAN. Refer to the warranty for further information. Field 
support for software is provided through upgrade facilities.

Push Button

Description

PORT SELECT

Press the 

PORT SELECT

 button to select the active 

port. Selection choices cycle through the following 

order: No Port, Nx64k, G.703, SHDSL.

LOCAL 

LOOP/ ERR 

INJ

If a port is selected, and a Bit Error Rate Test (BERT) is 

not in progress, press the 

LOCAL LOOP/ERR INJ

 

button to initiate or terminate a local loop on the 

selected port. If a BERT is in progress, press the but-

ton to inject a single bit error.

REMOTE 

LOOP

If the SHDSL port is selected, press the 

REMOTE 

LOOP

 

button to place or remove a remote loop on the 

port by sending a EOC request message to the LTU 

(or NTU in campus mode). If the Nx64K port or G.703 

port (with only one service defined) is selected, press 

this button to place or remove a remote loop on the 

selected port's single data service by sending respec-

tive inband loop up or loop down patterns to the far 

end (in the associated data service timeslots).

BERT

If a port is selected and there are no local loops, press 

the 

BERT

 button to start or stop a BERT on the 

selected port.

Summary of Contents for 6540

Page 1: ...WS 15 Minute Threshold Alarm 2 Major SHDSL port alarms LOS LOSW or Segment Defect 3 Minor G 703 port alarms Rx RAI Frame Slip CRC 4 errors LBER and any ES SES UAS and CVC 15 Minute Threshold Alarm 4 Major G 703 port alarms LOS LOF LOMF Rx AIS or HBER 5 Nx64K port alarms Clock Slip Loss of External Clock FIFO Underflow Over flow and Inactivity Alarm G 703 z z z Off Green Yellow Red Port is not acti...

Page 2: ...té et la réglementation Ausführliche Sicherheits und regulatorische Informationen sind in der Konformitätserklärung zur Sicherheit und Einhaltung von Normen zu diesem Produkt 6123001E1 17 aufgeführt PUSH BUTTONS MAINTENANCE The 6540 does not require routine hardware maintenance for normal operation Do not attempt repairs in the field Repair services may be obtained by returning the defective unit ...

Page 3: ...t 3 Customer Non Transparent 4 Network Transparent 5 Network Non Transparent 1 ALT 2 2047 3 2E15 1 4 QRSS 5 Test Options 1 Permanent Off 2 DTE Driven 1 LTU 2 NTU 1 Interface Mode 2 Payload Rate kbps 3 SNR Margin Alarm Threshold dB 4 Loop Attenuation Alarm Threshold dB 5 Outage Auto Retrain 6 PM Thresholds 1 Disabled 2 Enabled 0 Disabled 1 900 Seconds 1 Disabled 2 Enabled 1 Disabled 2 Enabled 00h t...

Page 4: ...adtran com Warranty ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service Warranty information can be found online at www adtran com warranty 2011 ADTRAN Inc All Rights Reserved ADTRAN CUSTOMER CARE From within the U S 1 800 726 8663 From outside the U S 1 256 963 8716 PRICING AND AVAILABILITY 1 800 827 0807...

Reviews: