3

3. Before installing the fiber, use an optical power meter to 

measure the power level. The power level should not 
exceed –8.0 dBm. Use an appropriate bi-directional optical 
attenuator if the power levels are at or above –8.0 dBm. A 
level between –8.0 dBm and –28.0 dBm is acceptable, but 
levels between –12.0 dBm and –18.0 dBm are optimal.

4. Refer to the and connect the Incoming Fiber Connector.

Figure 4. Fiber Installed

g

     NOTE

When the SC/APC fiber connection is not in use, replace the 
Protective Cover. This will help keep the optical connection clean.

Step 5: Connect 12 VDC Power or UPS Power

Refer to 

Figure 1

 and the following steps when connecting power. 

The Micro ONT can be powered by either the 12 VDC connection, 
or by using the UPS connection. 

w

     NOTICE

DO NOT connect both power sources as, this will damage the 
Micro ONT.

12 VDC Connection

To power the Micro ONT using the 12 VDC connection, complete 
the following steps:

1. Plug the supplied 12 V AC/DC Power Converter into the 

PWR

 connection. 

2. Connect the power plug to a standard AC outlet. This 

immediately turns the unit ON.

UPS Connection 

To power the Micro ONT using an UPS, refer to 

Figure 5

 an

complete the following steps:

1. If using the ADTRAN Cable Assembly (see Note below), 

connect one end to the Molex Connector and the other to 
the UPS. This immediately turns the unit ON.

Figure 5. Molex Connector

g

     NOTE

ADTRAN offers a 24W UPS (P/N 1187731G3) and GPON Indoor 
UPS Power Cable (P/N 1287402G1) for providing an UPS power 
source.

Incoming 
Fiber

UPS Power/Alarm Table

The following table indicates which pin is associated with each 
alarm provided through a UPS connection.

LED S

TATUS

The LEDs are located beneath the plastic housing and are only 
visible after power has been applied. The following table provides 
the LED status during normal operations.

T

ROUBLESHOOTING

The following table provides troubleshooting tips.

Pin-Out

Description

Alarm

1

Power Input (+12 VDC)

-

2

UPS Status - On Battery

1

3

UPS Status - Battery Missing

2

4

Signal Return

5

Power 12 V Return

-

6

UPS Status - Replace Battery

3

7

UPS Status - Low Battery

4

8

No Connection 

Label

Status

Indication

POWER

Off
Green

ONT power is Off
ONT power On

FIBER

2

Off
Green
Green Flashing 
Fast

ONT is not active (not Ranged)
ONT is active (Ranged)
ONT is activating (Ranging in 
progress)

LAN

2

Off
Green

Green Flashing 
Fast

LAN Port is not connected
LAN Port is connected, but 
data is not being transmitted
LAN Port is connected, and 
data is being transmitted 

VOICE

2

Off

Green
Green Flashing 
Slow

Unequipped or on-hook and 
not ringing
Off-hook
On-hook with line in ringing 
state

Problem

Possible Solution

The LAN LED is

flashing red

Use an optical power meter to check 
the receiving power to see if it between 
–28 dbm and –8 dbm.

Reset the ONT using the Reset button. 
If the ONT fails again, replace the ONT 
with another unit.

The FIBER LED is off 
when the Ethernet cable 
is connected

Check the FIBER connection, or check to 
see if the Ethernet service is disabled. Con-
tact the Central Office for verification.

Summary of Contents for 411

Page 1: ...al up connections AC Power The power feed is 12 VDC from the included AC to DC Adapter The adapter plugs into the PWR connector UPS The Micro ONT provides an optional connection for an uninterpre table power source UPS An UPS is a battery backup system designed to continue providing power when the primary power source is lost Power is supplied to the Micro ONT by a local power source with battery ...

Page 2: ...ling the Micro ONT inspect it for damage If damage has occurred during shipping file a claim with the carrier and then contact ADTRAN For more information refer to the warranty Installation Guidelines The following are guidelines for this installation Read all warnings and cautions before installing or servicing the Micro ONT Do not locate the Micro ONT in direct sunlight or next to any thermal ob...

Page 3: ...1187731G3 and GPON Indoor UPS Power Cable P N 1287402G1 for providing an UPS power source Incoming Fiber UPS Power Alarm Table The following table indicates which pin is associated with each alarm provided through a UPS connection LED STATUS The LEDs are located beneath the plastic housing and are only visible after power has been applied The following table provides the LED status during normal o...

Page 4: ...ral Office determine if there are alarms on the PON feeding the ONT If no alarms exist use an optical power meter to troubleshoot the fiber network Problem Possible Solution Physical Width 2 8 in 7 1 cm Depth 4 0 in 10 2 cm Height 1 2 in 3 0 cm Weight 1 lbs 0 45 kg Environmental Operational Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 F to 122 F 20 C to 50 C Relative Humidity 90 non...

Reviews: