This document supports the following ONTs:

The ADTRAN 411 1 Pots + 1GigE (Micro ONT) is an Optical 
Network Terminal (ONT). 

Figure 1

 illustrates the key features on 

the Micro ONT.

Figure 1. Micro ONT Key Features

The table opposite provides descriptions for each feature number 
above.

Part Number

Description

1287787F1

ADTRAN 411 Micro ONT (NA)

1287787F4

ADTRAN 411 Micro ONT (AUS)

4

6

5

1

2

3

7

PWR

VOICE

LAN

FIBER

POWER

VOICE

LAN

PWR

VOICE

LAN

FIBER

FIBER

8

Fiber (FIBER)

Fiber is supplied to the Micro ONT using an SC/APC Fiber 
connection located on the rear of the unit.

Ethernet Interface (LAN)

The Micro ONT supports data service through one 10/100/
1000BASE-T Ethernet interface via an RJ-45-style connector. 

POTS (VOICE)

Plain Old Telephone Service (POTS) uses in-band signaling tones 
and currents to determine call status (for example, call request). 
Because POTS allows for the transfer of audio signals below 3.3 
kHz, POTS systems are also used for modems that allow data 
transmission (referred to as dial up connections). 

AC Power

The power feed is +12 VDC from the included AC to DC Adapter. 
The adapter plugs into the PWR connector. 

UPS

The Micro ONT provides an optional connection for an uninterpre-
table power source (UPS). An UPS is a battery backup system 
designed to continue providing power when the primary power 
source is lost. Power is supplied to the Micro ONT by a local 
power source with battery backup that utilizes the AC power at the 
customer premises to charge the battery.

ONT Reset (RESET)

Refer to 

Figure 1

 for the location of the Reset button.

Reset the Micro ONT if you need to reboot the unit. The RESET 
button is accessed through an opening on the bottom of the unit. 
To reset the Micro ONT, insert a small pin (paper clip) into the 
RESET opening and hold the button down for 10 seconds.
The Micro ONT will automatically download the latest provisioning 
after the reset process has completed.

Number

Feature

1

Single GPON fiber interface with 1.244 Gbps upstream 
and 2.488 Gbps downstream

2

POTS (Voice) Interface

3

10/100/1000-BaseT Ethernet Interface (LAN)

4

AC Power Adapter

5

UPS Power/Alarm connector

6

Status LEDs

7

Reset Button

8

Keyholes

ADTRAN 411

Micro ONT

1 POTS + 1 GigE

August 2020

61287787F1-13A

Summary of Contents for 411

Page 1: ...al up connections AC Power The power feed is 12 VDC from the included AC to DC Adapter The adapter plugs into the PWR connector UPS The Micro ONT provides an optional connection for an uninterpre table power source UPS An UPS is a battery backup system designed to continue providing power when the primary power source is lost Power is supplied to the Micro ONT by a local power source with battery ...

Page 2: ...ling the Micro ONT inspect it for damage If damage has occurred during shipping file a claim with the carrier and then contact ADTRAN For more information refer to the warranty Installation Guidelines The following are guidelines for this installation Read all warnings and cautions before installing or servicing the Micro ONT Do not locate the Micro ONT in direct sunlight or next to any thermal ob...

Page 3: ...1187731G3 and GPON Indoor UPS Power Cable P N 1287402G1 for providing an UPS power source Incoming Fiber UPS Power Alarm Table The following table indicates which pin is associated with each alarm provided through a UPS connection LED STATUS The LEDs are located beneath the plastic housing and are only visible after power has been applied The following table provides the LED status during normal o...

Page 4: ...ral Office determine if there are alarms on the PON feeding the ONT If no alarms exist use an optical power meter to troubleshoot the fiber network Problem Possible Solution Physical Width 2 8 in 7 1 cm Depth 4 0 in 10 2 cm Height 1 2 in 3 0 cm Weight 1 lbs 0 45 kg Environmental Operational Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 F to 122 F 20 C to 50 C Relative Humidity 90 non...

Reviews: