NetVanta 1230 Series Hardware Installation Guide
Unit Installation
61702594G1-34C
Copyright © 2013 ADTRAN, Inc.
23
4.
UNIT INSTALLATION
The instructions and guidelines provided in this section cover hardware installation topics, such as mounting
options, supplying power to the unit, and installing option cards. These instructions are presented as follows:
•
Tools Required on page 23
•
Mounting Options on page 24
•
Supplying Power to the Unit on page 26
For information on configuring a specific application, refer to the configuration guides or the
AOS Command
Reference Guide
provided on the
ADTRAN Support Community
at
https:supportforums.adtran.com
.
Tools Required
The customer-provided tools required for the hardware installation of the NetVanta are:
•
Ethernet cables
•
Phillips-head screwdriver
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
The NetVanta 1230 Series is intended to be to be installed, maintained, and serviced by
qualified service personnel only and should be installed in a restricted access location as
described in UL/IEC 60950-1.
• Ethernet cables are intended for intrabuilding use only. Connecting an ADTRAN
unit directly to Ethernet cables that run outside the building in which the unit is
housed will void the user's warranty and could create a fire or shock hazard. To
connect an ADTRAN unit to Ethernet cables that run outside the building,
ADTRAN's Ethernet Port Protection Device (EPPD) (P/N 1700502G1) must be
connected between the unit and the outside plant cable. Use of any Ethernet
protector other than ADTRAN's for this purpose will void the user's warranty.
• PoE cables are intended for intrabuilding use only. Connecting an ADTRAN PoE
unit directly to PoE cables that run outside the building in which the unit is housed
will void the user's warranty and could create a fire or shock hazard.
• For outdoor PoE applications, ensure any PoE injector used is approved and
rated for outdoor/exposed wiring applications. Use of a PoE injector that is not
rated for outdoor/exposed wiring applications will void the user's warranty and
could create a fire or shock hazard.
To access the CLI of the NetVanta, you will also need a PC with VT-100 terminal emulation
software and a console port cable. Instructions on how to access the CLI are available in
the quick start guide shipped with your unit or online at the
ADTRAN Support Community
.