HDSL4 for General Distribution Installation and Maintenance Practice
Control Port Operation
61223HDSL4L2-5C
33
BERT Test Functions
When selecting the BERT Test Functions option from the Loopbacks and Test Commands
menu, the BERT Test Screen displays (
).
Figure 25. BERT Test Screen
The following options are available from the BERT Test Screen:
•
•
•
•
•
•
NOTE
The BERT only runs unframed patterns. When the BERT is run-
ning, option
5
changes to “Inject Bit Errors”.
(Re)start Pattern
The (Re)start Pattern option is used to start (or restart) a test.
Stop Test
The Stop Test option is used to manually stop the test.
Shelf: 1 Slot: 18 Total Access System 03/09/05 10:59
Unacknowledged Alarms: MAJOR INFO
Circuit ID:
BERT Test Screen
Test Results
-----------------------------------------------------
Test Direction: Customer
Unframed Pattern Generation: OFF
Pattern: QRSS Pattern
Line Coding: B8ZS
Bit Errors: 0000000
Bit Error Rate: 0.0E-08
Pattern Sync: N/A
Pattern Sync Losses: 000
Test Length (HH:MM:SS): 02:00:00
Time Elapsed (HH:MM:SS): 00:55:12
-----------------------------------------------------
1. (Re)start Pattern
2. Stop Test
3. Select Data Pattern
4. Enter Test Timeout
5. Toggle Test Direction
Selection: