Control Port Operation
HDSL4 for General Distribution Installation and Maintenance Practice
34
61223HDSL4L2-5C
Select Data Pattern
The Select Data Pattern option from the BERT Test Screen allows the appropriate data test
pattern for the desired results to be selected.
illustrates this screen with the menu
of test patterns.
Figure 26. Select Data Pattern
Enter Test Timeout
The Enter Test Timeout option displays the Timeout Screen (
). The timeout can run
for a specific duration by entering the hours and/or minutes, or can run indefinitely by
entering 00:00, per the note on the screen.
Figure 27. BERT Test Functions - Selection 4, Enter Test Time Out
Shelf: 1 Slot: 18 Total Access System 03/09/05 10:59
Unacknowledged Alarms: MAJOR INFO
Circuit ID:
CUSTOMER Pattern Screen
Current Pattern = QRSS Pattern
--------------------------------------
1. 63 Pattern
2. 511 Pattern
3. 2047 Pattern
4. REV. 2047 Pattern
5. 2^15 Pattern
6. 2^20 Pattern
7. QRSS Pattern
8. 2^23 Pattern
Selection:
Shelf: 1 Slot: 18 Total Access System 03/09/05 10:59
Unacknowledged Alarms: MAJOR INFO
Circuit ID:
CUSTOMER Timeout Screen
Test Timeout(Hr:Min) = 02:00
----------------------------
1. Change Timeout
*NOTE: When timeout is set to 00:00, the
test will run indefinitely.
Selection: