![ADT SERIES 4250 User Manual Download Page 20](http://html1.mh-extra.com/html/adt/series-4250/series-4250_user-manual_2853915020.webp)
19
U
NSETTING
THE
S
YSTEM
(
TURNING
THE
SYSTEM
OFF
)
PROBLEMS WHEN UNSETTING THE SYSTEM
Deviation from Entry route
Entering the premises via the designated route (Final exit
only door), the Entry/Exit buzzer (if fitted) and keypad
bleeper will sound intermittently. Deviating from the
designated route e.g. opening another door will cause
the sound to change to a continuous tone. On returning
to the designated route the audible indication will revert
to the intermittent sound, confirming that the zones have
been restored to normal.
Zones not restored during entry time
If zones outside the Entry route are not restored before
the Entry time expires and the x digit user code is entered
using the keypad then the display will indicate FULL-SET.
An alarm condition will be reported to the Alarm Receiving
Centre and the keypad status LED will flash red.
Deviation from the route is reported to the Alarm Receiving
Centre. The display will show System FULL SET and then
upon entering the x digit user code followed by enter the
keypad display will alternate between (a) and (b).
(a)
(b)
To obtain a system RESET refer to Page 16