USER GUIDE
SERIES 4250
AUDIO ALARM CONFIRMATION SYSTEM
CONTROL UNIT
Page 1: ...USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT...
Page 2: ...ULL SET condition 15 Unsetting from a FULL SET condition after Alarm activation 16 CONTENTS Page Unsetting from a PART SET condition 17 Problems when unsetting the system Deviation from Entry route 19...
Page 3: ...ntre where an operator can monitor and listen to the alarm activity at the premises and take the appropriate action This may include alerting the local police and or a designated keyholder in accordan...
Page 4: ...complete premises is required PART SET Partially armed Selected to turn the system on when protection is limited to pre defined areas of the premises e g upper floor rooms protected and lower floor ro...
Page 5: ...itting Diode status indicator on the keypad Part Set Security condition selected by the user at the keypad Chosen to allow pre defined areas of the premises to be protected when other areas are occupi...
Page 6: ...The last door closed by the user on exit and the first door opened on entry Exit Terminator A switch or push button located on the outside of the premises adjacent to the Final door Used to finally se...
Page 7: ...controls the system by means of a keypad Note The LCD will display messages prompt entries and indicate the functions of the selection keys enter LED Status Indicator Numeric Keys Keypad LCD Display...
Page 8: ...T mode Partially armed GREEN System is in UNSET mode Switched off FLASHING RED An alarm has occurred whilst system was in FULL SET mode FLASHING GREEN Mains power supply has failed NOTE Battery back u...
Page 9: ...press the enter button 5 Key in the x digit user code and press enter 6 After a short delay the code will be verified the keypad and Exit Entry buzzer if fitted will start to bleep The keypad will beg...
Page 10: ...ow a message indicating where the fault is located For example the following display indicates the system remains UNSET due to a fault in zone 05 Note A zone is an area such as a room or corridor that...
Page 11: ...y will show Retry key Press the RETRY key and enter the correct code After 3 attempts to enter your code the system will refuse further setting attempts for two minutes and this condition is reported...
Page 12: ...o the normal intermittent bleep and you will be able to exit normally If any zones having been entered by deviating from the exit route are not restored e g doors not closed within the set exit time t...
Page 13: ...emises with in the set exit time the setting fault condition will be indicated on the keypad LCD as shown The FAIL TO EXIT condition is reported to the Alarm Receiving Centre and the keypad audible to...
Page 14: ...a similar time delay to allow the user to key in the x digit user code to UNSET switch off the system During both time delays the keypad will bleep An example of using this selection is a house with...
Page 15: ...play will show Delay key Instant key 4 Select Delay if time delay is required to exit the protected area or Instant if no time delay is required 5 When Delay or Instant is selected the display will re...
Page 16: ...designated Exit Entry door or route 2 The keypad bleeper and Entry route buzzer if fitted will sound intermittently as a reminder to disarm the system before the entry time expires The display will sh...
Page 17: ...alarm has occurred The keypad display will alternate between By pressing the key on the keypad the display will show the alarm history log indicating where the intrusion has taken place The user must...
Page 18: ...To UNSET the system from PART SET with Delay carry out the following 1 Enter the protected area by the designated route the keypad bleeper will sound and the keypad display will show Unset key 2 Press...
Page 19: ...rom PART SET with Instant carry out the following 1 The keypad display will show 2 Press the Unset key 3 Key in the x digit user code and press enter UNSETTING THE SYSTEM TURNING THE SYSTEM OFF 4 The...
Page 20: ...mittent sound confirming that the zones have been restored to normal Zones not restored during entry time If zones outside the Entry route are not restored before the Entry time expires and the x digi...
Page 21: ...lay will change to Yes key No key 4 Press YES key The Alarm Receiving Centre will now reset the system Note Whilst a RESET following an alarm activation can be carried out by the Alarm Receiving Centr...
Page 22: ...es To notify the Alarm Receiving Centre of an emergency duress situation key in your Duress code and press enter The emergency alarm signal will be sent to the Alarm Receiving Centre who will alert th...
Page 23: ...red while the system was armed the keypad status LED will also indicate this by flashing RED To view the Alarm History Log after an alarm activation carry out the following 1 Unset the system 2 The di...
Page 24: ...from the back up battery supply The keypad status LED will flash GREEN and the Alarm Receiving Centre will be notified The Keypad LCD Display will show FULL SET CONDITION PART SET CONDITION UNSET COND...
Page 25: ...RY FAILURE Battery failure is notified to the Alarm Receiving Centre and the keypad display will show FULL SET CONDITION PART SET CONDITION UNSET CONDITION OR OR If the fault persists contact the Alar...
Page 26: ...d in the system will operate to warn the user of this condition and the Keypad will display The user can cancel the audible warning by entering their normal x digit user code whilst the keypad will co...
Page 27: ...the Line fault condition during the system being set e g The system will also attempt to link up with the Alarm Receiving Centre NOTE If the Line fault condition appears to be permanent contact the A...
Page 28: ...amper condition arises during the UNSET period the fault will be audibly notified and indicated on the keypad display If a zone tamper fault exists the display will identify the fault If a system tamp...
Page 29: ...dibly in the same way as a tamper condition and confirmed by the keypad display e g Similary to silence the audible warning the x digit user code is entered on the keypad which results in the display...
Page 30: ...es 1 Confirming the operational status of the system 2 Obtaining a system reset following an alarm incident To send a test signal the system must be in the UNSET condition as shown by the display Pres...
Page 31: ...30 TEST SIGNAL Press the Call key The display will show Yes key No key Press the YES key to send the test signal the Alarm Receiving Centre Operator will notify the user as appropriate...
Page 32: ...ill indicate when someone enters or exits a specified area The alarm is NOT reported to the Alarm Receiving Centre To select the Chime mode carry out the following 1 At the keypad select PART SET and...
Page 33: ...32 CHIME MODE OPTIONAL FEATURE To disable the Chime mode carry out the following 1 Select PART SET Quiet Key 2 Press Quiet key 3 Key in x digit user code and press enter...
Page 34: ...ystem key 4 Press the Change Code key 5 Key in the new user assigned code and press enter 6 Verification of the new user code is now prompted Key in the new user code again and press enter NOTE If a k...
Page 35: ...2 Press Full Set key the display will change and prompt for the master code to be entered 3 Key in the x digit master code and press enter 4 Press the Yes key to arm all the partitions The display wi...
Page 36: ...nge to a request to enter the x digit master code 2 Key in the master code and press enter 3 Carry out the FULL SET procedure The omitted zone is reported to the Alarm Receiving Centre On entering the...
Page 37: ...alarms To view the alarm history 1 Ensure the system is UNSET if not carry out the unsetting procedure 2 Key in the x digit master code and press enter 3 The display will change and display a prompt t...
Page 38: ...ZST952 ISSUE 1...