Determine your desired new User Code or Master User Code sequence. If you

make an error while programming, press the      key five times and start over from
step 1.

WARNING: Pressing the       or  *   key while programmlng a code may
result In Improper code operation, therefore you MUST return to step 1

when an error Is made.

1.

2.

3.

4.

5.

To Change A 

 Code

The system must be disarmed.

Press key 

9 and hold 

for three seconds. The control station will beep three times.

Enter the Master User Code. The control station will beep two times. The
READY and ARMED indicators will blink alternately and the other eight
indicators will blink repeatedly when the programming mode is successfully
entered (see note   on page 

Press a key (Z-6) which corresponds to the User Code you wish to program, or
press key 1 to change the Master User Code, then press the       key. For

example, press 1, then  to change the Master User Code, or 4 then   to program
User Code 4, etc. The control station will beep three times to signify acceptance.

Enter the desired new 4 digit code sequence. After the fourth digit is entered,

the control station will emit one short beep followed by one long beep then the

system will exit the programming mode automatically. To program another
code, return to step 2.

1.

2.

3.

4.

5.

6.

The 

system 

must 

be disarmed.

Press key 9 and hold for three seconds. The control station will beep three times.

Enter the Master User Code. The control station will beep two times. The

READY and ARMED indicators will blink alternately and the other eight
indicators will blink in sequence with each other when the programming mode
is successfully entered (see note 

 key   then key 0, then # which instructs the control that you wish to delete

a code. The control station will beep three times to signify acceptance.

Enter the number of the code (l-6) to be deleted.

The code is now deleted. The system will automatically exit the programming

mode.

B

Summary of Contents for Safewatch Plus Enterpreneur Security Systems

Page 1: ......

Page 2: ......

Page 3: ...False Alarms 6 THE EMERGENCY KEYPAD PANIC ALARMS 7 Emergency Alarm Activation 7 Resetting The Emergency Alarm 7 SPECIAL FEATURES 8 Chime Mode 8 Force Arming 8 Bypassing Zones 9 Key Switch Operation 10 Access 10 The Reset Key 10 Remote Programming 10 Audible Zone Testing 11 FIRE DETECTION 12 What To Do If The Fire Alarm Sounds 12 Fire Supervlsoryflrouble Resetting Smoke Detectors 12 Emergency Evacu...

Page 4: ...Depending upon the I installation this card pulls 1 out from the left or right I Armed Status If lighted the system is armed condition exists Contact your security representative side of the control station Trouble Indicator f ighted a trouble Alarm Co Police Fire If not lighted the system is disarmed If b inking time is being provided to exit the building after which the system will be armed Alar...

Page 5: ... an exit delay time which allows a specific amount of time to leave through any delay defined intrusion detection zone without causing an alarm Be sure that you have been informed on routes to enter and exit from without causing an alarm If too much time is taken to exit the beeping tone will change to a steady tone indicating the start of entry delay Disarm the control and start over to avoid a f...

Page 6: ...elay may also be programmed to automatically turn off at this time When the system is disarmed the interior and delaywilI return to their normal on or off state See your security representative for details Q Two Digit Arming Your system may have been programmed with an abbreviated arming feature When this feature is enabled only the first two digits of your User Code will be required to arm the sy...

Page 7: ...rm has occurred Leave the premises immediately and go to the nearest phone to contact the appropriate authorities Do not procede into the premises 2 Enter your User Code 3 The red armed light should turn off indicating that the system is disarmed Testing the Burglar and Fire Alarm Audibles UL listed burglar and fire alarm systems which have separate audible sounding devices require a weekly test N...

Page 8: ...tifying the specific area that was violated Use the zone I D card to determine the area of protection which corresponds to each zone If the alarm was activated manually by pressing one of the emergency keys no zone indicators will be lighted Press the key to extinguish the ALARM indicator after determining the type of alarm that occurred and area of protection involved A history of the alarm condi...

Page 9: ...a specific type of alarm as programmed and labeled by your installer To activate an Emergency Alarm 1 Press the appropriate emergency panic key The Emergency Alarm will activate NOTE Your lnstalter may have progmmmed the panic zones to ignore momentaty key presses and to activate only by pressing and holding pressed for three seconds or pressing at least twice within three sec onds Checkwlthyoutse...

Page 10: ... The control station will now beep two times when any burglar zone is opened Note The CHIME feature does not annunciate lntertor zones To Turn The CHIME Off Press the 6 key and hold for three seconds The control station will beep two times to signify that the CHIME has been turned off Your system may be programmed for quick arming even with one or more zones faulted In this condition when an attem...

Page 11: ...em must be disarmed Press the BYPASS key then enter the number of the zone l 6 to be bypassed The corresponding ZONE indicators l 6 will blink to indicate zones that have been bypassed The blinking will cease 30 seconds after the system is armed and the exit delay expires Repeat steps 2 and 3 to bypass other zones To Cancel A Zone Bypass The system must be disarmed Press the BYPASS key followed by...

Page 12: ...e ACCESS feature the control station can be used to switch other devices on and off or as a timed switch This feature is most commonly used to activate an electric door release or switch lights on and off Consult your security representative for more information The key may be used to D Silence the control station sounder and the audible output during Auxiliary A Fire and Auxiliary C Emergency ala...

Page 13: ... fully understand thlsopwatlon USER CODES Your system may be programmed to accept up to five regular User Codes and one Muster User Code Each code may be comprised of any four digit sequence Do not program 1234 or 1111 as User Codes Codes may be added deleted or changed as necessary The Master User Code code 1 performs all of the User Code functions plus allows access to the programming mode User ...

Page 14: ...ress 1 then to change the Master User Code or 4 then to program User Code 4 etc The control station will beep three times to signify acceptance Enter the desired new 4 digit code sequence After the fourth digit is entered the control station will emit one short beep followed by one long beep then the system will exit the programming mode automatically To program another code return to step 2 1 2 3...

Page 15: ... see note Press key 6 then to instruct the control that you wish to program the desired code sequence for User Code 6 The control station will beep three times Enter the desired four digit code sequence After the fourth digit is entered the control station will emit one short beep followed by one long beep then the system will exit the programming mode automatically Repeat step 2 to re enter the p...

Page 16: ...Notes ...

Page 17: ...ior to beginning the walk test mode please note that the control station will beep continuously as a result of the non secure zones This will eliminate the advantages of the audible walk test mode although the zone indicator lights may still be relied upon for testing Press key 8 and hold for three seconds The control station will beep three times to signify entry into the TEST mode Violate a dete...

Page 18: ... the alarm monitoring service or the proper authorities immediately if the alarm was unintentional The red ALARM light will remain on To clear the alarm enter a valid User Code If the TROUBLE indicator lights a Fire Supervisory Trouble condition may exist Consult your Security Representative to define the trouble condition Many smoke detectors latch on and illuminate a built in indicator when trig...

Page 19: ...mergency escape ladders for rooms above the first floor Check the ladders to be sure that they will reach the ground Draw a rough sketch of your escape plan so that everyone is familiar with it Practice your escape plan to assure that everyone knows what they have to do in an emergency situation 6 Establish a meeting place outside where your family is to report 7 Advise the local fire authority if...

Page 20: ...m ofthedoorwithyourhipagainstthemiddle andonehandagainstthetopedge Open slightly If there is arush of hot air slam the door quickly and latch it Unvented fire will build up considerable pressure Be sure that all the household realizes this danger Use your neighbors phone or street fire alarm box The job of extinguishing the fire should be left to the professionals Too many unforeseen things can oc...

Page 21: ...e lower level Ceiling mounted smoke alarms should be located in the center of the room or hall not less than 4 inches from any wall When the detector is mounted on a wall the top of the detector should be 4 to 12 inches from the ceiling Do not install smoke alarms where normal ambient temperatures are above lOOoF 37 8 C or below 40 F 4 C Also do not locate smoke detectors in front of air condition...

Page 22: ...ote or A Smoke Detector should be located on each story A Smoke Detector should be located between the sleeping area and the rest of the family living unit l Indicates required smoke detector Indicates smoke detector is optional if door is not provided between living and recreational rooms 16 ...

Page 23: ...e Faulted A detection area which is not secure such as a protected door or window which has been left open causing the control to loose its Ready status Force Arm To override To force the system to arm when one or more zones are not ready Hardwire Zones The six areas of protection referred to as Zones 1 6 on the control station Indicator Lights The ten lights LEDs on the control station Interior T...

Page 24: ......

Page 25: ......

Page 26: ...Notes 20 ...

Page 27: ...io antenna 2 Reiocate or move lhe alarm control away from the receiver 3 Plug the transformer for the alarm control Into a different outlet so that the receiver and the alarm are on different branch circuits 4 lf necessary the user should consult the afarm deafer or an experienced radiotelevision technlctan for additional suggestions The user may find the following booklet prepared by the Federal ...

Page 28: ...MOOSE Sentrol Inc resen es the rtght to change specifmtmns wthout notice tJ1991 Sentrol Inc ...

Reviews: