UNSETTING THE SYSTEM
NORMAL ENTRY
Unsetting starts immediately when the FINAL door is opened or an
ENTRY zone is activated. The sounder pulses slowly and the user
must go directly to the keypad and enter a valid PIN, followed by
A>, <B or ent. Users with group options, will access the UNSET
screen following PIN entry. This permits the user to unset specific
groups. To return to the SET screen press ent.
STRAYING FROM THE ENTRY ROUTE
Go directly to the keypad when entering the building. If the user
strays into a protected area and activates a zone, then a full alarm will
occur. The police may be called out and the system will have to be
reset.
SLOW ENTRY
Enter a valid PIN before the entry time expires. If the entry time
expires before a valid PIN is entered, then a full alarm will occur.
The sounder begins to pulse quickly when 75% of the entry time has
elapsed indicating time is running short.
CANCELLING ALARMS
To cancel an alarm, enter a valid PIN followed by ent at the keypad.
The keypad displays the details of the zone activated. When more
than one zone is activated, their details can be viewed using A> or
<B. Press ent to return to the banner. Certain types of alarms, once
cancelled, require a code with the appropriate reset authorisation to
be entered. The system prompts for a valid reset code by displaying
MANAGER RESET REQUIRED
or
ENGINEER RESET
REQUIRED
on the keypad.
MANAGER RESET
Entering a manager level PIN followed by ent, resets the system
following an alarm activation.
ENGINEER RESET
Certain types of alarm require an engineer to visit the site and, after
investigation, reset the system. In such cases, the system cannot be
reset until the engineer reset has been carried out.
Galaxy 500 V1.15
15.49 MON 18 Nov
PIN + ent
4 ALARMS
[<] [>] to View
PIN + ent
CALL MANAGER
RESET REQUIRED
CALL ENGINEER
RESET REQUIRED