UNSETTING THE SYSTEM

NORMAL ENTRY

Unsetting starts immediately when the FINAL door is opened or an
ENTRY zone is activated. The sounder pulses slowly and the user
must go directly to the keypad and enter a valid PIN, followed by
A>, <B or ent. Users with group options, will access the UNSET
screen following PIN entry. This permits the user to unset specific
groups. To return to the SET screen press ent.

STRAYING FROM THE ENTRY ROUTE

Go directly to the keypad when entering the building. If the user
strays into a protected area and activates a zone, then a full alarm will
occur. The police may be called out and the system will have to be
reset.

SLOW ENTRY

Enter a valid PIN before the entry time expires. If the entry time
expires before a valid PIN is entered, then a full alarm will occur.
The sounder begins to pulse quickly when 75% of the entry time has
elapsed indicating time is running short.

CANCELLING ALARMS

To cancel an alarm, enter a valid PIN followed by ent at the keypad.
The keypad displays the details of the zone activated. When more
than one zone is activated, their details can be viewed using A> or
<B. Press ent to return to the banner. Certain types of alarms, once
cancelled, require a code with the appropriate reset authorisation to
be entered. The system prompts for a valid reset code by displaying

MANAGER RESET REQUIRED 

or 

ENGINEER RESET

REQUIRED

 on the keypad.

MANAGER RESET

Entering a manager level PIN followed by ent, resets the system
following an alarm activation.

ENGINEER RESET

Certain types of alarm require an engineer to visit the site and, after
investigation, reset the system. In such cases, the system cannot be
reset until the engineer reset has been carried out.

Galaxy 500 V1.15

15.49 MON 18 Nov

PIN + ent

4 ALARMS

[<] [>] to View

PIN + ent

CALL MANAGER

RESET REQUIRED

CALL ENGINEER

RESET REQUIRED

Technical Manuals Online! - http://www.tech-man.com

Summary of Contents for Galaxy 18

Page 1: ...Galaxy 8 18 60 500 512 User Guide 9 3 6 8 0 2 5 7 1 4 A ent esc B Galaxy 512 V1 15 11 42 TUE 11 OCT Technical Manuals Online http www tech man com...

Page 2: ...Technical Manuals Online http www tech man com...

Page 3: ...ing from the Entry Route 5 Slow Entry 5 Cancelling Alarms 5 Manager Reset 5 Engineer Reset 5 Menu Options 6 Accessing the Menu 6 Full Menu 6 Quick Menu 6 Quick Menu Options Table 7 Omit Zones 8 Omitti...

Page 4: ...odes 15 Modify PIN 16 Dual Codes 16 Modify Level 17 Duress Code 17 Modify Name 18 Time Zone 18 Temporary Codes 19 PIN Change Codes 19 Modify Groups 20 Group Choice 21 MAX Number 21 MAX Function 22 MAX...

Page 5: ...act a computer which has been designed using the latest software and hardware technology First and foremost the Galaxy meets all your security needs The engineer will program and commission the system...

Page 6: ...used where groups are programmed on the system permitting groups areas to be set or unset VIEW KEYS A and B These keys have been programmed to activate one of the system options Pressing the A key aft...

Page 7: ...following a valid code entry STAR KEY T T T T T The T key is used to provide additional features for certain options e g printing the event log or deleting entries POWER LED The green power LED remain...

Page 8: ...screen Select which groups have to be to set by entering the number of the group For example to set groups 2 and 3 press keys 2 and 3 The display changes to indicate the groups selected for setting P...

Page 9: ...ual termination is made the system waits four seconds before setting The sounders emit two long tones to confirm that the system is set The keypad briefly displays the message SYSTEM SET before becomi...

Page 10: ...e quickly when 75 of the entry time has elapsed indicating time is running short CANCELLING ALARMS To cancel an alarm enter a valid PIN followed by ent at the keypad The keypad displays the details of...

Page 11: ...e all groups assigned to the user code must be unset 2 If the user has group choice at least one group on the system must be unset 3 If there are no groups then the system must be unset FULL MENU The...

Page 12: ...1 3 5 e t a D e m i T 7 1 4 6 s e d o C 8 2 4 6 r e m m u S 9 3 4 6 t e S d e m i T 2 1 3 t e S t r a P 3 1 3 t e S t n a t s n I 6 1 3 t r a P t n a t s n I 7 1 3 t e S e m o H 8 1 3 t e S l l A 9 1...

Page 13: ...g the same method NOTE A zone is omitted from the system as soon as the key is pressed The system does not have to be set for this to come into effect SETTING WITH OMITTED ZONES When the list of omitt...

Page 14: ...ORCED SET User Level 3 and above PURPOSE The FORCED SET option allows the user to automatically omit zones eligible for omission which are open when the system setting routine is started Zones omitted...

Page 15: ...chime attribute by the engineer continue to chime when they are activated Note The CHIME mode is suspended while the system is set or during an alarm DISPLAY ZONES User Level 4 and above PURPOSE This...

Page 16: ...ce and RIO voltage ESCAPE The esc key aborts the option and returns to the option menu DISPLAY LOG User Level 4 and above PURPOSE DISPLAY LOG provides the user with a means of viewing the system histo...

Page 17: ...stem print options are displayed Pressing the esc key aborts the PRINT option CODES Press key 1 to start the print out of all the codes giving the user number name level and length of code ZONES Selec...

Page 18: ...and stops when all zones are closed NOTE The TEST ALL ZONES option only tests zones which can be omitted from the system SELECTED ZONES Choosing the SELECTED ZONES option by pressing key 2 displays th...

Page 19: ...invalid dates e g 14 12 99 Pressing the esc key aborts the entry ADVANCE AND RETARD It is possible to advance and retard the time to compensate for any variations in clock speed Press the key when in...

Page 20: ...Assign the MAX features to the code The manager code defaults to group choice when groups are enabled The manager is able to toggle the group choice option on and off using the T key as required GALA...

Page 21: ...s displayed in the top line of the users details screen ASSIGNING DUAL CODES To program a user code as a Dual Code press the key while the Modify PIN option is selected The displays at the start of th...

Page 22: ...e s y l n o n a C 2 r e k a t e r a C m e t s y s e h t t e s n u d n a t e s y l n o n a C 3 s r e s U 9 1 1 1 s n o i t p O u n e M 4 s r e s U 9 2 1 1 s n o i t p O u n e M 5 s r e s U 9 3 1 1 s n...

Page 23: ...lt or previous name When the previ ous name has been erased use the A or B keys to move the cursor to the first letter of the name and press the ent key The selected character appears on the top line...

Page 24: ...Warning option This prompts the user to assign a new code whenever the expiring code is entered during the PIN Warning period except during system unsetting The new PIN must be six digits and must be...

Page 25: ...s have been assigned to the user press the ent key to accept the programming and return to the previous menu level GALAXY 500 and 512 The Galaxy 500 has 16 groups and the 512 has 32 groups The groups...

Page 26: ...to group 4 cannot assign group 4 to another user code MAX NUMBER Each MAX card has a unique 10 digit number laser etched onto it A MAX card is assigned to a user by entering this number in the MAX Num...

Page 27: ...used CARD HELD MAX OPERATION The MAX function is activated when the card is held directly in front of a MAX reader for three seconds The MAX reader must be assigned a common group to the MAX user The...

Page 28: ...display the first MAX user number User 201 Each of the users can be displayed using the A and B keys or a specific user can be selected by entering the required user number When the required code is...

Page 29: ...d on the keypad in blocks of eight groups labelled A B C and D Use the A or B keys to move between the group blocks Press keys 1 8 to assign the groups in each block to the user SUMMER User Level 6 On...

Page 30: ...tems These should be switched off if possible 4 Always follow the exit entry route procedure agreed with your alarm installer 5 Treat the alarm components with care to ensure they are not damaged 6 Co...

Page 31: ...c n u F n o i t p i r c s e D e m i h C t i m O t r a P 1 2 3 4 5 6 7 8 1 1 0 1 2 1 0 1 3 1 0 1 4 1 0 1 5 1 0 1 6 1 0 1 7 1 0 1 8 1 0 1 e n o Z n o i t c n u F n o i t p i r c s e D e m i h C t i m O...

Page 32: ...set the alarm Tamper alarms usually require an engineer to visit the site to check all modules on the system This message is displayed when a tamper alarm occurs NO ENTRIES This message appears if a u...

Page 33: ...User Guide 28 Galaxy 8 18 60 500 512 Name Address Telephone Office Hours Other Times Account No INSTALLER DETAILS Technical Manuals Online http www tech man com...

Page 34: ...Galaxy 8 18 60 500 512 29 User Guide Technical Manuals Online http www tech man com...

Page 35: ...User Guide 30 Galaxy 8 18 60 500 512 Technical Manuals Online http www tech man com...

Reviews: