7.3 Network connection (RJ45)
If the drivers required for functioning are installed on the device, the control system may be integrated in
an Ethernet network supporting the 10/100/1000Mbit standard by using the Ethernet 10/100/1000BaseT
network connector. The specifications of this network topology must be observed. If the drivers required
for function are not installed, they can be installed from the website (www.ads-tec.de).
10/100Mbit
Pin-Number
Signal-Name
1
TX +
2
TX -
3
RX +
4
NC
5
NC
6
RX -
7
NC
8
NC
1000 BaseT
Pin-Number
Signal-Name
1
D1+
2
D1-
3
D2+
4
D3+
5
D3-
6
D2-
7
D4+
8
D4-