3.9 Environmental Conditions
The unit can be put into operation and used under the following conditions. Failure to observe any one
of the specified data will immediately terminate all warranty conditions. ads-tec cannot be held liable for
any damages arising due to improper device or unit use and handling.
Permissible ambient temperatue
during operation
5 … 60° C
during operation (UL)
5 … 50° C
during storage
-
20 … 50° C
Humidity
during operation
10 … 85% without condensate
during storage
10 … 85% without condensate
Vibration
during operation
1 G, 10 … 500 Hz
(DIN EN 60068-2-6)
Shock
During operation
5 G, with half-wave of 30 ms
(DIN EN 60068-2-29)
Note: