Advanced RF Technologies, Inc.
41
7.3.1
General Settings
The General Settings section allows the user to enable/disable amplifiers and the ALC routine.
Figure 7-7
Control Tab – General Setting
ALC ON: Enables or disables Automatic Level Control (ALC)
PSR 700 DL HPA On: Enables or disables the Downlink High Power Amplifier (HPA) for 700MHz PS
PSR 800 DL HPA On: Enables or disables the Downlink High Power Amplifier (HPA) for 800MHz PS
PSR 700+800 UL HPA On: Enables or disables the Uplink High Power Amplifier (HPA) for 700+800MHz
PS
Remote Power Switch: Enables or disables the Remote Power Switch function
To enable/disable any of the settings, click on the checkbox and click the Apply button.
7.3.1.1
Emergency Power Off Switch Support
The PSR-78-9533-UA now support the ability to connect an extern power switch to turn on/off the high power
amplifier via our Alarm Input dry contact pins. This Emergency Power Off (EPO) function is an optional feature that
is only active when the function is enabled. If the EPO function is enabled, the AAI dry contact input alarm pair will
no longer function. This feature is available on firmware version 2.0.33 or higher and older repeaters can be
updated using a field upgradeable firmware.
On the dry contact alarming cable, if the Alarm Input-1 & GND (light blue pair) is an open circuit, the DL and UL
HPA will be turned on. If this pair is shorted together (closed circuit) then the DL and UL HPA will turn off. If
needed, the cable length can be extended up to approximately 300 ft. using CAT6 Shielded Twisted Pair cable.
Figure 7-8
AAI Alarm Cable – Alarm Input
7.3.2
System
Under the System section, the user is able to perform a soft reboot on the repeater and also can restore
factory default settings.
Figure 7-9
Control Tab – System
Reboot: Performs a soft reboot of the repeater
Factory Set: Restores all settings to factory defaults
Summary of Contents for PSR-78-9533-UA
Page 36: ...Advanced RF Technologies Inc 36 7 2 Status Tab Figure 7 3 Status Tab ...
Page 40: ...Advanced RF Technologies Inc 40 7 3 Control Tab Figure 7 6 Control Tab ...
Page 43: ...Advanced RF Technologies Inc 43 7 4 Install Tab Figure 7 12 Install Tab ...
Page 57: ...Advanced RF Technologies Inc 57 Figure 11 2 PSR ANN Annunciator Mechanical Drawing ...
Page 58: ...Advanced RF Technologies Inc 58 Figure 11 3 ADRF BBL U Mechanical Drawing ...
Page 59: ...Advanced RF Technologies Inc 59 Figure 11 4 ADRF BBS U Mechanical Drawing ...