background image

 

Advanced RF Technologies, Inc. 

      

 

 

PSR-78-9533-UA MANUAL 

VERSION 0.33 

 

 
 

 

 

 

 

3116 West Vanowen St. 

Burbank, CA 91505 

Tel: 818-840-8131 

Fax: 818-840-8138 

www.adrftech.com

 

 

 

Summary of Contents for PSR-78-9533-UA

Page 1: ...Advanced RF Technologies Inc i PSR 78 9533 UA MANUAL VERSION 0 33 3116 West Vanowen St Burbank CA 91505 Tel 818 840 8131 Fax 818 840 8138 www adrftech com ...

Page 2: ...ice Advanced RF Technologies Inc 1996 2019 All rights reserved Please send comments to E Mail info adrftech com Phone 818 840 8131 800 313 9345 Fax 818 840 8138 Address Advanced RF Technologies Inc Attention Technical Publications Department 3116 Vanowen St Burbank CA 91505 USA www adrftech com ...

Page 3: ... HISTORY CHANGE LIST Version Change list Contents Version Author Descriptions Date 0 1 ADRF Initial Release 08 07 2019 0 12 ADRF update 09 11 2019 0 22 ADRF B9B Update 08 04 2020 0 23 ADRF updfate 09 04 2020 0 33 ADRF U Type updfate 09 23 2021 ...

Page 4: ... the ADRF BBS BBL 24 24V battery backup unit via a dedicated cable provided by the ADRF 22 3 3 6 Grounding 23 4 Alarms 24 4 1 Message Board Alarms and Notifications 24 4 2 External Alarms 25 4 2 1 External Alarm Output interface 25 5 Installation 26 5 1 Installation Procedures 26 5 1 1 Wall Mount Procedure 26 5 1 2 PSR ANN Annunciator Installation 26 5 2 Antenna Separation Isolation 28 6 ADRF BBL ...

Page 5: ... 46 7 4 8 Date Time 46 7 5 System 47 7 5 1 System Account 47 7 5 1 1 System Account Account Management 47 7 5 1 2 System Account New Account 47 7 5 1 3 System Account Change Password 47 7 5 2 System SNMP 48 7 5 3 System Logs 48 7 5 4 System Update 49 7 5 5 System Backup Restore 50 7 6 Help 51 7 7 Logout 51 8 Maintenance Guide for PSR 78 9533 U 9537 U Repeater 51 8 1 Periodic Inspection Checklist 5...

Page 6: ... Figure 2 5 External Alarm Port 20 Figure 2 6 RF Ports 21 Figure 2 10 Annunciator Port 22 Figure 2 7 Battery Backup Port 4 pin Female 22 Figure 2 8 Battery Switch 22 Figure 2 9 Ground Cable Terminal 23 Figure 4 1 Wall Mount 26 Figure 4 2 PSR ANN Repeater Mount 27 Figure 4 3 PSR ANN Wall Mount 27 Figure 4 4 RF Repeater Oscillation 28 Figure 5 1 Login Page 35 Figure 5 2 Status Tab 36 Figure 5 3 Stat...

Page 7: ... 27 SNMP 48 Figure 5 28 System Logs 49 Figure 5 29 System Update 49 Figure 5 30 System Update is Complete Popup Message 50 Figure 5 31 System Backup Restore 50 Figure 5 32 Help 51 Figure 9 1 PSR 78 9533 X Mechanical Drawing 오류 책갈피가 정의되어 있지 않습니다 Figure 9 2 PSR 78 9533 UA Mechanical Drawing 오류 책갈피가 정의되어 있지 않습니다 Figure 9 3 PSR ANN Annunciator Mechanical Drawing 오류 책갈피가 정의되어 있지 않습니다 TABLES Table 1 1 P...

Page 8: ...d signal DAS Distributed Antenna System DL Downlink HPA High Power Amplifier HW Hardware IF Intermediate Frequency LNA Low Noise Amplifier LTE Long Term Evolution MS Mobile Station OFDM Orthogonal Frequency Division Multiplexing OFDMA Orthogonal Frequency Division Multiple Access PAR PAPR Peak to Average Power Ratio Crest Factor PLL Phase Locked Loop PSU Power Supply Unit QAM Quadrature Amplitude ...

Page 9: ...vised circuits for antenna amplifier power supply battery and charger failure IP66 compliant enclosure for both indoor and outdoor environments Class B wideband repeater designations Up to 95dB of gain and up to 37 dBm downlink output power per band and up to 30 dBm uplink output power shared 1 1 Highlights UL 2524 Certified Supports both 700MHz and 800MHz Public Safety Frequencies in a single rep...

Page 10: ...ts List Label Quantity Description A 1 PSR 78 9533 UA B 1 Wall Mount Bracket C 1 Mounting Bracket Template D 1 AAI Alarm Cable E 1 Ethernet Cable Crossover F 4 Anchor Bolt G 1 PSR ANN Annunciator Panel A B C D E F G Figure 1 1 PSR 78 9533 UA Repeater Parts List ...

Page 11: ...nal Figure 1 3 PSR 78 9533 UA Quick View Bottom AAI Alarm Port Battery backup Port Donor Port 4 3 10 Female AC Input Port Ground Terminal Server Port 4 3 10 Female Sever CPL DL Output Monitor Port 30dB Donor CPL UL Output Monitor Port 30dB Heat Sink Annunciator Communication Power Port GUI Port ...

Page 12: ...Advanced RF Technologies Inc 12 Figure 1 4 PSR ANN Annunciator Audible Alarm Speaker Alarm Indicator Lights Data Power Port Repeater Wall Mount Bracket ...

Page 13: ...distance is determined upon gain of antenna used Please maintain a minimum safe distance of 210 cm while operating near the donor and the server antennas Also In accordance with the FCC regulations 90 219 this device must meet 5W ERP requirements RF EXPOSURE ANTENNA PLACEMENT Guidelines Opening or tampering the PSR 78 9533 UA will void all warranties WARRANTY Lithium Battery CAUTION RISK OF EXPLOS...

Page 14: ...t generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense FCC Part 15 Class A WARNING THIS is NO...

Page 15: ...n maximal ou inférieur approuvé pour l émetteur par Industrie Canada Dans le but de réduire les risques de brouillage radioélectrique à l intention desautres utilisateurs il faut choisir le type d antenne et son gain de sorte que la puissance isotroperayonnée quivalente p i r e ne dépassepas l intensité nécessaire à l établissement d une communication satisfaisante Max peak gain 17 dBi RSS GEN 6 8...

Page 16: ...ble to use for the various cables that will be needed for the proper operation of the repeater To maintain UL 2524 Listed status unused ports must be properly weather proofed Table 2 1 Pre cut hole size and labels Silkscreen Label Location Diameter AC 100 240V LEFT 22 2mm 7 8 ANNUNCIATOR RIGHT 22 2mm 7 8 BATTERY ADRF BBU ONLY NON LPS RIGHT 22 2mm 7 8 DONOR BOTTOM 33 0mm 1 3 8 Ext ALARM BOTTOM 33 0...

Page 17: ...e server line as shown in the picture below Figure 2 2 Terminal Wiring Diagram 2 2 1 AC 100 240V Terminal Block The AC 100 240V Terminal Block is located on the left side of the wiring compartment One side of the terminal block will be pre wired and connected to the PSU and the chassis ground The open terminals must be connected to an AC power source between 100 240V AC and secured in an electrica...

Page 18: ...Input UL Return Power Door Open Over Current DL Over Input UL PLL Fail System Halt DL Over Power DL Return Power DL PLL Fail LED Indicator Specifications Solid Green Normal operation Solid Yellow Soft Fail alarm exists in the system Solid Red Hard Fail alarm exists in the system 3 2 Host Remote Switch The Host Remote Switch allows the user to switch the default Repeater IP Subnet Mask and Gateway ...

Page 19: ...ring compartment on the opposite side of the wiring compartment door The repeater and has a free voltage range input of 100 240V AC The AC terminal box can support a max gauge of 12AWG and should be connected to the breaker box on its own circuit Figure 3 1 AC Terminal Figure 3 2 AC On Off Switch The AC Power on off switch is on the left hand side of the PSU which is located inside of the repeater...

Page 20: ...y 70 _N 3 NEG Output G Orange System component malfunction_P 4 POS Output H Orange System component malfunction_N 4 NEG Output J Yellow Normal AC Power_P 5 POS Output K Yellow Normal AC Power_N 5 NEG Output L Green Loss of normal AC Power_P 6 POS Output M Green Loss of normal AC Power_N 6 NEG Output N Blue Battery charger failure_P 7 POS Output P Blue Battery charger failure_N 7 NEG Output Q Purpl...

Page 21: ...event feedback the donor and server antennas must be separated by an appropriate distance to provide sufficient isolation Isolation is attained by separating antennas a sufficient distance so that the output of one antenna does not reach the input of the other This distance is dependent on the gain of the repeater DONOR 4 3 10 female which is used to connect the donor antenna 700MHz 800MHz PS DONO...

Page 22: ...When the ADRF BBS BBL 24 is connected to the repeater the battery switch on the PSU must be switched to the ON position This will enable the repeater to charge the ADRF BBS BBL 24 battery backup unit when AC power is present Figure 3 7 Battery Switch The PSR 78 9533 UA can be connected to an ADRF BBS BBL 24 to provide power during a power failure If an ADRF BBS BBL 24 is utilized connect it to the...

Page 23: ...upport for assistance if you are unfamiliar with the installation procedure of the battery box 3 3 6 Grounding The grounding terminal is located at the lower right hand side of the BDA A grounding cable should be properly connected before powering on the equipment Figure 3 8 Ground Cable Terminal Ground terminals located on the side of the repeater and can support a ground cable up to 1 25mm 16AWG...

Page 24: ...ecified level default 85dBm 4 seconds Input Overload Incoming in band DL or UL signal is too strong Input signal is above the threshold 4 seconds Soft DL 5dBm UL 5dBm Hard DL 5dBm UL 5dBm Out of band Overload Incoming out band DL or UL signal is too strong Out of band signal is above the threshold 4 seconds Soft DL 5dBm UL 5dBm Hard DL 5dBm UL 5dBm Synthesizer Lock Fail There is an issue with the ...

Page 25: ... Signal Low Battery Capacity 70 depleted Low Battery Soft Fail Battery Depleted System Component Malfunction Over Current Hard Fail Over Temperature Hard Fail DSP Hard Fail Out band Overload Hard Fail Faulty or Damaged PSU Ambient Temperature DSP Filter Fault Strong RF Input Signal Normal AC Power AC Normal Set AC Fail Soft Clear Powered by AC Power Powered by DC Power Loss of Normal AC Power AC F...

Page 26: ...D cable Connect the Antenna cables Connect the Power cable Figure 5 1 Wall Mount 5 1 2 PSR ANN Annunciator Installation The PSR ANN annunciator box has been designed to either mount on top of the PSR 78 9533 UA repeater or can also be wall mounted separately By default the mounting bracket is configured to mount to the top of the repeater with the mounting bracket at the bottom of the PSR ANN annu...

Page 27: ...Advanced RF Technologies Inc 27 Figure 5 2 PSR ANN Repeater Mount Figure 5 3 PSR ANN Wall Mount ...

Page 28: ... being fed back into the system This creates a constant amplification of the same signal As a result the noise level rises above the signal level Figure 5 4 RF Repeater Oscillation To prevent feedback the donor and server antennas must be separated by an appropriate distance to provide sufficient isolation Isolation can be attained by separating antennas at a sufficient distance so that the output...

Page 29: ...ation between the donor antenna and the serving antennas is at least 15 dB greater than the BDA gain 3 Connect the cable from the donor antenna to the BDA connector labeled DONOR and the cable from the serving antennas to the BDA connector labeled SERVER 4 Connect the AC power cord to the BDA and turn on the switch at the left of PSU 5 Installation of the BDA is now complete Adjust the gain contro...

Page 30: ...ill switch back to operating with AC power and will resume charging the battery backup 1 Verify that the repeater has been properly grounded 2 Loosen each wheel lock by spinning the red dial to the left 3 Move the ADRF BBL U 24 to the desired location and spin the red dial to the right to tighten wheel locks 4 The brackets on the back of the ADRF BBL BBS U unit can be used to secure to the wall ON...

Page 31: ...RF BBL U set the power switch to the OFF position 7 On the PSR 78 9533 9537 U verify that both AC and BATT switches have been set to the OFF position 8 Use the provided battery backup cable from the ADRF BBL U and connect the wires to the terminal block located inside of the wiring compartment of the PSR 78 9533 9537 U ...

Page 32: ...ATTERY and snake the cable through the conduit 10 Install a conduit hub connector that can support 7 8 onto the ADRF BBL U hole labeled BATTERY 11 Open the wiring compartment of the ADRF BBL U and wire the battery cable to the terminal block 12 On the PSR 78 9537 U wire the AC terminal block to your dedicated circuit breaker ...

Page 33: ...Advanced RF Technologies Inc 33 13 On the PSR 78 9533 UA flip the POWER and BATT switch to the ON position 14 On the ADRF BBL U 24 set the circuit breaker to the ON position ...

Page 34: ...rogram feature or option Permitted in UL 2524 Y N Possible settings Settings permitted in UL 2524 Remote Power Switch N Enable Disable Disable Battery Not Charge Check Y On Off On Battery Check Y Check All Except Installed Check Off Check All Donor Antenna Malfunction Check Time Y 0sec 10sec 45sec 90sec 3min 6min 15min 30min 1hour 2hour 4hour 8hour 12hour 24hour and 48hour 0sec 10sec 45sec 90sec 3...

Page 35: ...ou are connecting to the unit remotely use of a modem then skip the step above Connect the RJ 45 crossover cable between the laptop s Ethernet port and the repeater s Ethernet port Launch either Internet Explorer or Google Chrome Type the following IP address into the address bar of the Internet Browser http 192 168 63 1 If you are connecting to the unit remotely then type the IP address of the mo...

Page 36: ...Advanced RF Technologies Inc 36 7 2 Status Tab Figure 7 3 Status Tab ...

Page 37: ...ays the Input Gain and Output for both downlink and uplink Figure 7 1 Status Tab Power Gain Display Input dBm Displays the in band Downlink Uplink signal level The system will display when the input level is 90 dBm Outband dBm Displays the out band composite power Gain dB o User Set Displays the amount of gain that the user set o Actual Displays the actual amount of gain that is currently in use O...

Page 38: ... section displays the AAI alarm status for each dry contact alarm Red indicates that the dry contact alarm is active and light blue indicates the alarm is inactive If the Remote Power Switch function is enabled then the AAI Alarm In status will not be present from the AAI alarm status since this function is disabled when the Remote Power Switch is enabled Figure 7 3 Status Tab AAI Alarm Display Re...

Page 39: ...ion Technical Support Installer Contact Info Repeater Info Displays the serial number latitude longitude firmware version and Web GUI version Repeater Location Displays the address where the repeater is installed Technical Support Displays ADRF s Technical Support contact information Installer Contact Info Displays the installer s name phone and e mail address ...

Page 40: ...Advanced RF Technologies Inc 40 7 3 Control Tab Figure 7 6 Control Tab ...

Page 41: ... power amplifier via our Alarm Input dry contact pins This Emergency Power Off EPO function is an optional feature that is only active when the function is enabled If the EPO function is enabled the AAI dry contact input alarm pair will no longer function This feature is available on firmware version 2 0 33 or higher and older repeaters can be updated using a field upgradeable firmware On the dry ...

Page 42: ...he signal can be before triggering a Downlink Signal Not Detected soft fail alarm DL RF Power Level Allows the user to set a maximum deviation value for the downlink RF power before triggering a DL RF Power Level soft fail alarm For example if the input signal is 50 dBm and the gain is set to 60 dB the expected output power should be 10 dBm If the Downlink RF Power alarm value is set to 6dB then a...

Page 43: ...Advanced RF Technologies Inc 43 7 4 Install Tab Figure 7 12 Install Tab ...

Page 44: ...logy The following choices are available from the drop down menu N PS700 16ch PS800 16ch 758 861MHz S1 PS700 12ch PS800 20ch 758 861MHz S7 PS700 32ch 758 775MHz S8 PS800 32ch 851 861MHz 7 4 2 Band Selection Figure 7 14 Install Tab Band Selection Band selection allows the user to specify the desired frequencies by inputting the center frequencies and selecting the bandwidths ...

Page 45: ...er bandwidth Downlink Gain Minor gain adjustments can be performed on a per channel basis to equalize signal levels Downlink Freq Start Displays the start frequency of the pass band once the band selection has been set Downlink Freq End Displays the end frequency of the pass band once the band selection has been set 7 4 3 SNMP Figure 7 15 Install Tab SNMP The SNMP section allows you to specify the...

Page 46: ...ab This feature is only available if the Emergency Power Off switch function is not being utilized Figure 7 18 Install Tab AAI Input 7 4 7 Location Info Installer Info This section allows the user to specify the address of the repeater and also the information of the installer Figure7 19 Install Tab Location Info Installer Info 7 4 8 Date Time This section allows the user to specify the current da...

Page 47: ...istrator To delete a user account click on the Account Management link and under the Edit column click on the delete button Figure 7 21 System Account Account Management 7 5 1 2 System Account New Account The New account section allows the Administrator to create a new user account Please note that the New account section is only available if you are logged into the system as the Administrator To ...

Page 48: ...SNMP v1 v2c and v3 Community strings for v1 v2c can be specified from here and SNMP user account can be created deleted from this section Figure 7 24 SNMP 7 5 3 System Logs This section displays system events that have taken place The Log displays the time and date of when the event took place and what changes were made to the system ...

Page 49: ...ware update click on the Update tab and the following screen will appear Figure 7 26 System Update Click on the Choose File button and locate the firmware file Click on the Upgrade button to perform the firmware update Once the firmware update is complete the following popup message will appear ...

Page 50: ...up Restore section allows the user to save the settings of the repeater To perform the backup click on the Backup button and you will be prompted to save the backup file To restore the settings to the system click on Choose File button select the backup file and click the Restore button Figure 7 28 System Backup Restore ...

Page 51: ...epeater remote brackets are in good condition and that the repeater remote is securely fastened f Verify that the repeater has 3 of clearance on all sides to ensure proper ventilation 2 Battery Backup a Open the ADRF BBL U BBS U enclosure and inspect the battery terminals for any corrosion buildup b Turn the circuit breaker to the off position and unscrew the fuse holder to inspect the fuse i A sp...

Page 52: ...or the balance of the applicable period of the original warranty or ninety days from the date of shipment of a repaired or replaced product whichever is longer 9 3 Limitation of Damages The liability for any defective product shall in no event exceed the purchase price for the defective product 9 4 No Consequential Damages Advanced RF Technologies Inc has no liability for general consequential inc...

Page 53: ...ous FirstNet Narrow Band Up to 16 Non contiguous PS 700 PS 800 Up to 32 Non contiguous PS 700 PS 800 Filter Bandwidth Broad MHz 5 10MHz Narrow KHz 6 25 75 6 25 x n n 1 12 Filter Roll off Broad MHz 60dBc Filter Bandwidth Edge 1MHz Narrow KHz 55dBc Filter Bandwidth Edge 3 Filter BW Spurious FCC Rule Compliant Passband Ripple 2 dB ALC Dynamic Range 60dB Gain Dynamic Range 45dB Channel Setting Resolut...

Page 54: ...g PSR 78 9533 UA 100 240 VAC 50 60 Hz 1 93 0 84A or 27VDC 4 85A Battery Port Only Annunciator Rating 28VDC Nominal 108 3mA AC Supply Protection Fuse Circuit Protector T6 3L250V Ground External Threaded Stud Battery Type Valve Regulated Sealed Lead Acid Rechargeable Battery Battery Model ADRF BBL U 24 Tempest TR120 12 ADRF BBS U 24 Tempest TR45 12 Battery Capacity TR120 12 120Ah TR45 12 48Ah Maximu...

Page 55: ...94A Runtime h 22 67h PSR 78 9533 UB Dual Band w 2 ADRF BBS U 24 ADRF BBX U CBL 21P Repeater DC Power Consumption W 127 16 DC Voltage V 24 02 DC Current Draw A 5 294 2 Battery Backup w Parallel Cable Battery Capacity Ah 96 Calculations Runtime h Battery Capacity Ah Current Draw A Runtime h 96Ah 5 294A Runtime h 18 13h 10 5 Warranty Certificates Table 10 4 Warranty Certificates Parameters Specificat...

Page 56: ...Advanced RF Technologies Inc 56 11 ANICAL DRAWING Figure 11 1 PSR 78 9533 U Mechanical Drawing ...

Page 57: ...Advanced RF Technologies Inc 57 Figure 11 2 PSR ANN Annunciator Mechanical Drawing ...

Page 58: ...Advanced RF Technologies Inc 58 Figure 11 3 ADRF BBL U Mechanical Drawing ...

Page 59: ...Advanced RF Technologies Inc 59 Figure 11 4 ADRF BBS U Mechanical Drawing ...

Page 60: ...r on the HPAs and check to see if the hard fail alarm still exists If the hard fail alarm still exists then the repeater will shut down for 1 minute double the time of the previous shutdown time After 1 minute has elapsed the repeater will power on the HPAs and check to see if the hard fail alarm still exists If the hard fail alarm still exists then the repeater will shut down for 2 minutes double...