With the increase in altitude at which it measurement shall be taken the amount column of 

the atmosphere decreases, as well as the pressure measured. Pressure changes with altitude within 
the first  2000m above the sea are fast - with an increase of altitude about 8m atmospheric pressure 
decreases about 1 hPa (see further - bar degree). As a result, measurements made at the same point 
and at the same time at different heights, give different pressure values. In addition the changes in 
pressure at the same point will be affected by the changes in air temperature. 

 

     

4. Drivers installing 

 

Please  install  on  the  PC  the  USB  drivers.  The  drivers  can  be  downloaded  from 

www.adrel.com.pl/download

 - file Altimetr_Program.zip and unzip tem to any folder.  Then copy 

the contents of the folder …/Sterowniki_Builder/ to folder …/windows/system32. They are files : 
<tee35.bpl>  and <vcl35.bpl>. 

 Then  connect  the  altimeter  to  the  computer  via 

adapter  or  cable  with  a  5-pin  tip  (described  above). 
For  the  connection  additional  hubs  can  not  be  used. 
Altimeter  must  be  connected  via  a  USB  cable  AB 
type with plugs directly into the computer. Windows 
automatically  detects  the  connected  device.  On  the 
screen  Found  New  Hardware  Wizard  will  appear. 
Select "Not this time" and press "Next". 

  

Then  select  "Install  from  a  list  or  specific 

location" and press "Next". 
 

Summary of Contents for ALTIMETER ALT-USB

Page 1: ......

Page 2: ...ent time 1 5h for 1 5 sec measurement 400 sec for 10 measurements sec 260 sec for 15 measurements sec 160 sec for 25 measurements sec 80 sec for 50 measurements sec total of 4000 measurements Measurement triggering Set in the range of 2 200 m Measurement end Start level 7m Then 32 additional measurements are taken Dimensions 9 5 x 24 x 7 mm with connector Weight 1 2 g without battery Recommended b...

Page 3: ...hich takes into account the current pressure pressure changes temperature vertical temperature gradient change of the density of the atmosphere depending on altitude Model Altimeter AL 01 is used for measuring the height of the model and the analysis of the flight Measurements are stored in nonvolatile memory so they are saved when device is disconnected from power Frequency of measurement is set ...

Page 4: ...ir temperature 4 Drivers installing Please install on the PC the USB drivers The drivers can be downloaded from www adrel com pl download file Altimetr_Program zip and unzip tem to any folder Then copy the contents of the folder Sterowniki_Builder to folder windows system32 They are files tee35 bpl and vcl35 bpl Then connect the altimeter to the computer via adapter or cable with a 5 pin tip descr...

Page 5: ...s 2000 xpvista7 Windows XP Vista 7 x 32 vista64 Windows Vista x 64 And press OK This brings up a warning message Ignore it or press Continue Anyway The driver will be installed At the end choose Finish Then we need to check the COM port number at which the driver has been installed Then we choose in turn Start Control Panel System or Start Control Panel Performance and Maintenance System His bring...

Page 6: ...ll the driver 1 Download the Driver Signature Enforcement Overrider http www ngohq com home php page dseo 2 Start the DSEO no installation is needed 3 Choose Sign a System File click the next button and sign lowcdc inf 4 Choose Sign a System File again click the next button and sign lowcdc sys 5 Choose Enable Testmode and click the next button 6 Restart your computer 5 The maintenance program of t...

Page 7: ...imeter is assembled can not be tight There must be holes allowing the pressure around the altimeter to equalize atmospheric pressure Before inserting into the enclosure you should make sure that the LED is blinking single flashes altimeter alarm reset Be careful with any assembly work so as not to produce negative pressure in the chamber of the altimeter Particular attention should be paid when re...

Page 8: ...ot get lower 32 more measurements will be taken and the cycle is completed The end is signaled by three blinks of LED as in the absence of zeroing You can disconnect the battery and connect the altimeter to the computer to read data If the end of the measurements was not detected automatically you must short the contacts for a while like the return to zero The measurement is completed 8 Reading of...

Page 9: ...filled so that one could not connect the altimeter in the opposite way http www tme eu pl katalog art ZL265 5SG id_category 3D100035 26 zl265 5sg connector for soldering http www maritex com pl pl shop products ggid 9326 PBMS05S LF connector for soldering BLMS05 Crimp Terminal Housing 5 pins single row clamped connectors BLMT Metal terminal for BLMS and BLMD type housings 10 Charging the battery U...

Reviews: