<4. Wiring>
26
IM 01E25A01-01EN
4.3.1 When waterproof property is neces
-
sary (Wiring using waterproof glands)
IMPORTANT
To prevent water or condensation from entering the
transmitter housing, waterproof glands are recommended.
Do not over-tighten the glands or damage to the cables
may result. Tightness of the gland can be checked by
confirming that the cable is held firmly in place.
For working on the conduit or the flexible tubes (G1/2),
remove the waterproof gland and attach them directly to
the electrical connection.
(1) Waterproof Gland
Integral Flowmeter
Optional code: EG2, EG3
Cable
Waterproof gland
Gasket
Washer
F0405.ai
Remote Sensor
Optional code: EG
Washer
F0406.ai
Cable
Waterproof gland
Gasket
Remote Transmitter (AXW4A)
Optional code: EG4, EG5
Cable
Waterproof gland
Gasket
Washer
F0407.ai
Remote Transmitter (AXFA11)
Optional code: EG
Cable
Waterproof gland
Gasket
Washer
F0408.ai