background image

Suzhou Alston D.M Laser Technology Co., Ltd

DemonMao

9

and other highly reflective materials).

Step 4: Display control operation (manual mode and linkage mode).

Manual mode

1) The startup page is shown in Figure 6;
2) Click the manual mode to enter the parameter setting page, where you can set the power and
frequency, as shown in Figure 7;
3) For parameter setting, click on the number with your finger, and then select the parameter after
the digital meter appears, and finally click "" to confirm;

Linkage mode

Click linkage mode to enter the parameter setting page, you can set power, frequency, speed and
width, the interface operation method is the same as manual operation

Summary of Contents for RFL-7C-0200

Page 1: ...Suzhou Alston D M Laser Technology Co Ltd DemonMao 1 RFL 7C 0200 Hand held Laser Cleaner User Manual...

Page 2: ...emical reagents media dust and water It can remove resin paint oil dirt dirt rust coating plating and oxide layer on the surface of the object It has a wide range of applications including ships auto...

Page 3: ...ironmental protection Easy to operate just power on and it can be hand held or matched with a manipulator to realize automatic cleaning High cleaning efficiency saving time The laser cleaning system i...

Page 4: ...n width 10 80mm Move method Hand held 1 4 Main purpose and scope of application The RFL 7C 0200 hand held laser cleaner produced by our company adopts high power fiber laser The photoelectric system i...

Page 5: ...requirements and user guides and GB10320 88 laser equipment and facilities electrical safety standards 2 3 Safety signs There are no components in the product that need to be used by the operator plea...

Page 6: ...trained and approved by the equipment manufacturer and the parameter value before the change should be recorded so that it can be restored to the original state when necessary b The laser used for pr...

Page 7: ...If the water level is too low please add pure water to the normal range of the scale bar if the water level is normal turn the air switch upwards and the whole machine is powered on Check whether the...

Page 8: ...button reset the Emergency stop button 2 Turn the Power key switch to the right and the POWER green indicator light is on 3 After the green indicator light is on for 10 seconds press the LASER button...

Page 9: ...e to enter the parameter setting page where you can set the power and frequency as shown in Figure 7 3 For parameter setting click on the number with your finger and then select the parameter after th...

Page 10: ...h the speed adjustment is used to adjust the scanning speed and the copper tube at the top of the cleaning head is used to connect the dust collector Step 8 After use turn off the machine in reverse o...

Page 11: ...properly connected before starting up If not it is forbidden to start up and use it 5 It is forbidden to use the light outlet at a right angle of 90 degrees to the cleaned surface during use so as no...

Page 12: ...s protective lens field lens etc directly with your hands which may cause scratches on the lens surface If there is oil stains or dust on the lens surface it will seriously affect the use of the lens...

Page 13: ...ce is flat and there is no lens holder use lens paper to clean such as cleaning the mirror when the mirror surface is curved or the mirror surface has a lens holder use a cotton swab to clean such as...

Page 14: ...e placed in a non vibrating environment otherwise it will easily cause the lens to deform and affect the performance of the lens 4 4 Maintenance and maintenance during long term parking Pay attention...