Operation Theorem • 17
Figure 9 illustrates the available signal destinations for Trigger Bus[7..0]. Signal
names in the solid-line boxes represent the external (physical) signals on
connectors while signals in the dotted-line boxes represent the switch module’s
internal signal.
Figure 9: Available signal sources for Trigger Bus[7..0]
Trigger Bus[7..0]
WDT Overflow
SHDNn
Software Trigger
Star Trigger In
Trigger In Signal
Scanner Adv. Signal
AUX [3…2]