16.
Servo On
: Set the SVON signal output status. The
related function is _8154_set_servo().
17.
Play Key
:
Left play button
: Clicking this button will cause the 8154 start
to outlet pulses according to previous setting.
Z
In “Absolute Mode,” it causes the axis to move to
position1.
Z
In “Relative Mode,” it causes the axis to move forward.
Z
In “Cont. Move,” it causes the axis to start to move
according to the velocity setting.
Z
In “Manual Pulser Move,” it causes the axis to go into
pulse move. The speed limit is the value set by “Maxi-
mum Velocity.”
Right play button
: Clicking this button will cause the 8154
start to outlet pulses according to previous setting.
Z
In “Absolute Mode,” it causes the axis to move to posi-
tion.
Z
In “Relative Mode,” it causes the axis to move back-
wards.
Z
In “Cont. Move,” it causes the axis to start to move
according to the velocity setting, but in the opposite
direction.
Z
In “Manual Pulser Move,” it causes the axis to go into
pulse move. The speed limit is the value set by “Maxi-
mum Velocity.”
Summary of Contents for PCI-8154