28
Operation Theory
4.1
AD Conversion and Preloaded Trigger
4.1.1
ADC
The PCI-8136 provides 6 differential ADC channels. Each channel
consists of two inputs. One for a (+) signal and the other for a (-)
signal. The input signal may have a voltage range from –10 ~
+10V or current range from –20mA ~ 20mA. The following figure
show the A (voltage or current) to D (value read) converting table.
The zero voltage or current is at value 2000.
Related functions:
_8136_A_Initial
(): please refer to section 5.5
_8136_A_Read_Value
(),
_8136_A_Read_Volt
(): please refer
to section 5.5
4.1.2
Voltage Compare
The voltage compare function allows users to set a compare value
by software function. When one ADC signal reaches the pre-set
value, an interrupt will be generated for corresponding channel.
Relative functions:
_8136_A_Set_Compare_Value
(),
_8136_A_Set_Compare_Volt
(),
_8136_S_Set_Int_Factor
() : please refer to section 5,7