background image

Leading

EDGE COMPUTING

Manual Rev.: 

1.1

Rev. Date: 

September 28, 2021

Part Number: 

50M-00048-1010

HPERC-KBL-MC/MH

High Performance Extreme Rugged Computer System

User’s Manual

Summary of Contents for HPERC-KBL-MC

Page 1: ...Leading EDGE COMPUTING Manual Rev 1 1 Rev Date September 28 2021 Part Number 50M 00048 1010 HPERC KBL MC MH High Performance Extreme Rugged Computer System User s Manual...

Page 2: ...ii Revision History Revision History Revision Description of Changes Release Date 1 0 Initial release 2020 03 02 1 1 Add MXM T1000 MXM module update specifiations and pin definitions 2021 09 28...

Page 3: ...s Restriction of Hazardous Substances RoHS directive and Waste Electrical and Electronic Equipment WEEE directive Environmental protection is a top priority for ADLINK We have enforced measures to en...

Page 4: ...his manual to make sure that users perform certain tasks and instructions properly NOTE NOTE Additional information aids and tips that help users perform tasks CAUTION Information to prevent minor phy...

Page 5: ...losure 7 2 4 Connecting Peripherals 11 2 5 Front Panel Connectors LEDs 12 2 6 Breakout Cable Descriptions 14 2 7 P2 and P3 Military Connectors 15 2 7 1 P2 and P3 Connector Locations 15 2 7 2 P2 Pin De...

Page 6: ...4 3 3 6 NCT5104DSEC Super IO Configuration 36 3 3 7 Serial Port Console Redirection 37 3 3 8 Network Stack Configuration 41 3 3 9 CSM Configuration 41 3 3 10 USB Configuration 42 3 4 Chipset 43 3 4 1...

Page 7: ...ories 6 Figure 2 1 Top and Front Views of MH Enclosure with Mounting Dimensions 8 Figure 2 2 Top and Front Views of MC Enclosure with Mounting Dimensions 9 Figure 2 3 Bottom View of MC Enclosure with...

Page 8: ...viii List of Figures This page intentionally left blank...

Page 9: ...tions 2 Table 1 2 System Power Requirements 5 Table 2 1 I O Panel Connectors 13 Table 2 2 DB9 Male Connector Pin Definition 14 Table 2 3 GPIO Breakout Wires 14 Table 2 4 P2 Connector Pin Definitions a...

Page 10: ...x List of Tables This page intentionally left blank...

Page 11: ...this guide include X Preparing to use the HPERC KBL M and inspecting the accessories X Connecting peripherals to the HPERC KBL M X Powering up the HPERC KBL M Information not provided in this User s...

Page 12: ...ts GPGPU Optional NVIDIA Quadro P1000 P2000 w 4GB GDDR5 memory in MXM slot NVIDIA Quadro T1000 w 4GB GDDR6 memory in MXM slot Gigabit Ethernet Four Intel i210 10 100 1000 Ethernet ports Serial Port Se...

Page 13: ...Shock Table 516 6 I 40 G for Ground Equipment MIL STD 810G Method 516 6 Procedure V Crash Hazard Table 516 6 I 75 G for Crash Hazard Shock Vibration MIL STD 810G Method 514 6 Table 514 6C X Category...

Page 14: ...GA HD Audio 4x USB 2 0 PCIe x4 PCIe Switch 1 2 XIO2001 PCIe to PCI Bridge PCIe x1 PCI 104 Express Type B Connector PCI 32bit 33 66MHz PCIe x4 PCI 104 Express Type A connector Type 2 SMBus 2x USB2 0 PC...

Page 15: ...power draw of the HPERC KBL M featuring the Intel Xeon Processor E3 1505M v6 3 00GHz Input power is 24 VDC regulated Table 1 2 System Power Requirements Parameter Current Power Idle Windows 10 1 1A 2...

Page 16: ...separately Figure 1 2 HPERC KBL M Unit with Optional Accessories SATA Cooling Fins pre installed on MH version only Mounting Brackets Breakout Cables HPERC Accessories sold separately AC Mating Cable...

Page 17: ...stricted airflow The air temperature inside the enclosure could rise above the specified operating temperature limits if the airflow through the cooling solution is restricted Select workbench locatio...

Page 18: ...2 8 000 0 006 203 20 0 15 1 000 0 008 25 4 0 2 2 000 0 016 50 8 0 4 1 000 0 008 25 4 0 2 2 756 0 008 70 0 2 0 374 0 008 9 5 0 2 8 587 0 020 218 1 0 5 8 805 0 026 223 65 0 65 10 000 0 022 254 0 55 2 43...

Page 19: ...2 7 000 0 014 177 80 0 35 0 547 13 9 8 000 0 008 203 2 0 2 8 587 0 020 218 1 0 5 2 000 0 008 50 8 0 2 6 000 0 008 152 4 0 2 8 805 0 026 223 65 0 65 1 410 0 014 35 82 0 35 2 953 0 014 75 0 35 4 495 0 0...

Page 20: ...2 000 0 008 50 8 0 2 2 000 0 008 50 8 0 2 1 398 0 008 35 5 0 2 3 500 0 008 88 9 0 2 5 138 0 008 130 5 0 2 5 843 0 008 148 4 0 2 1 398 0 008 35 5 0 2 7 646 0 008 194 2 0 2 1 723 0 008 43 78 0 20 4 022...

Page 21: ...escriptions of the connectors before making connections or powering on the HPERC KBL M Connect the USB or PS2 keyboard to the corresponding connector on the corresponding breakout cable Connect the US...

Page 22: ...12 2 5 Front Panel Connectors LEDs Figure 2 4 Front View of HPERC KBL M I O Panel P1 DC Power In P2 Military Connector HPERC KBL MH HPERC KBL MC P3 Military Connector...

Page 23: ...witch Ethernet LEDs and UNDIO P3 Military Connector This military connector provides signals for VGA Ethernet LEDs Ethernet Ports Serial Ports PS 2 Keyboard and Mouse and RCA Jack L1 L2 Status LEDs Th...

Page 24: ...tion Pin RS232 RS422 1 NC NC 2 RXp 3 TXp 4 NC NC 5 NC NC 6 NC NC 7 TX TXn 8 RX RXn 9 NC NC Table 2 3 GPIO Breakout Wires Function Label Pin Signal GPIO1 P2 45 UDNIO13 GPIO2 P2 46 UDNIO14 GPIO3 P2 48 U...

Page 25: ...o military I O connectors P2 and P3 on the HPERC KBL M Each table lists the P2 or P3 pin numbers the signal names and descriptions Figure 2 5 provides the number and location of each pin on the two mi...

Page 26: ...B_GND5 Ground 15 USB 2 0 Port 4 P5V_USB4 5 Volts Power 16 USB 2 0 Port 5 P5V_USB5 5 Volts Power 17 Serial 4 RS422_TX4_N Transmit Data Negative 18 Serial 4 RS422_TX4_P Transmit Data Positive 19 Serial...

Page 27: ...put Output Port 19 55 User Defined IO UDNIO20 User Input Output Port 20 56 Ground GND Ground 57 81 NC NA NA 71 User Defined IO UDNIO5 User Input Output Port 5 72 User Defined IO UDNIO6 User Input Outp...

Page 28: ...e 108 Serial 5 RS422_TX5_P Transmit Data Positive 109 Serial 5 RS422_RX5_N Receive Data Negative 110 Serial 5 RS422_RX5_P Receive Data Positive 111 Serial 7 RS422_TX7_N Transmit Data Negative 112 Seri...

Page 29: ...D Ground 24 Control Indicator PCIe_ETH_5 5_LED1 Ethernet LED 114 Control Indicator PCIe_ETH_4 5_LED1 Ethernet LED 121 Control Indicator PCIe_ETH_3 5_LED1 Ethernet LED 16 Gigabit Ethernet 4 GbE5_MDI0_N...

Page 30: ...DDIB_N1 Digital Display Interface Port B TMDS Data 1 Negative 53 Ground GND Ground 54 DVI 1 DDIB_P0 Digital Display Interface Port B TMDS Data 2 Positive 55 DVI 1 DDIB_N0 Digital Display Interface Por...

Page 31: ...C TMDS Clock Negative 95 DVI 2 DDPC_AUX_SEL DisplayPort C Auxiliary Select 65 PS 2 Mouse CLK_MS_CON Mouse Clock 66 PS 2 Mouse DAT_MS_CON Mouse Data 76 NC NA NA 67 PS 2 Keyboard CLK_KBD_CON Keyboard C...

Page 32: ...net 3 GbE4_MDI0_P Ethernet0 Positive 111 Ground GND Ground 112 Gigabit Ethernet 3 GbE4_MDI2_N Ethernet2 Negative 113 Gigabit Ethernet 3 GbE4_MDI2_P Ethernet2 Positive 30 Ground GND Ground 31 Gigabit E...

Page 33: ...see POST complete successfully before the system starts loading the operat ing system optional If you are using Linux the boot loader will appear first similar to the one shown below with the correspo...

Page 34: ...enings on the HPERC KBL M enclosure may compro mise the IP67 ingress rating performance of the system It is strongly recommended to return the system to ADLINK for servicing If you wish to attempt acc...

Page 35: ...nformation Processor Information IGFX VBIOS Version Memory RC Version Total Memory Memory Frequency PCH Information ME FW Version ME Firmware SKU SPI Clock Frequency System Language System Management...

Page 36: ...re Options Description Name Info only Processor codename Name Info only CPU Brand String CPU Signature Info only CPU Brand String CPU Speed Info only Standard CPU frequency Processor ID Info only CPUI...

Page 37: ...nfo only Version Feature Options Description ME Firmware SKU Info only SKU Feature Options Description DOFR Support Info only Supported Read Status Clock Frequency Info only Frequency Write Status Clo...

Page 38: ...e MAC ID Info only Display SEMA MAC ID SEMA Features Info only Display features info Feature Options Description CPU Temperature Current Info only Display CPU current temperature Startup Info only Dis...

Page 39: ...urrent Runtime Read only The returned value specifies the time in seconds the system is running in S0 state This counter is cleared when the system is removed from the external power supply Power Cycl...

Page 40: ...Options Description System Language English Choose the system default language Feature Options Description System Date Day MM DD YYYY Set the date Use Tab to switch between Date elements System Time H...

Page 41: ...isplay L4 cache size Intel VMX Technology Info only Display Intel VMX technology support Intel SMX TXT Technology Info only Display Intel SMX TXT technology support Intel VMX Virtualization Technology...

Page 42: ...ed Enabled Enable Disable processor Turbo Mode requires EMTTM enabled AUTO means enabled unless max turbo ratio is bigger than 16 SKL A0 W A Config TDP Configurations Submenu Feature Options Descripti...

Page 43: ...atus SHA 1 PCR Bank Enabled Disabled Enable or Disable SHA 1 PCR Bank SHA256 PCR Bank Enabled Disabled Enable or Disable SHA256 PCR Bank Pending operation None TPM Clear Pending operation Platform Hie...

Page 44: ...Port 2 Configuration Submenu Set Parameters of Serial Port 2 COMB Serial Port 3 Configuration Submenu Set Parameters of Serial Port 3 COMC Serial Port 4 Configuration Submenu Set Parameters of Serial...

Page 45: ...ble Serial Port COM Device Setting Info only Change Setting Auto IO 3E8h IRQ 7 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 IO 2F0h IRQ 3 4 5 6 7 10 11 12 IO 2E0h IRQ 3 4 5 6 7 10 11...

Page 46: ...erial Port COM Device Settings Info only Change Setting Auto IO 240h IRQ 7 IO 240h IRQ 3 4 5 7 10 11 12 IO 248h IRQ 3 4 5 7 10 11 12 IO 250h IRQ 3 4 5 7 10 11 12 IO 258h IRQ 3 4 5 7 10 11 12 Select an...

Page 47: ...nable or Disable Console Redirection Settings Submenu The settings specify how the host computer and the remote computer which the user is using will exchange data Both computers should have the same...

Page 48: ...le Redirection Disabled Enabled Console Redirection Enable or Disable Console Redirection Settings Submenu The settings specify how the host computer and the remote computer which the user is using wi...

Page 49: ...rdware RTS CTS Flow control can prevent data loss from buffer overflow When sending if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start...

Page 50: ...ption Out of Band Mgmt Port COM1 COM2 COM3 COM4 COM5 COM6 COM7 Microsoft Windows Emergency Management Services EMS allows for remote management of a Windows Server OS through a serial port Terminal Ty...

Page 51: ...it time to press ESC key to abort the PXE boot Media detect count 1 Number of times presence of media will be checked Feature Options Description CSM Support Enabled Disabled Enable Disable CSM Suppor...

Page 52: ...only for EFI applications XHCI Hand off Enabled Disabled This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver EHCI Hand off Disabled E...

Page 53: ...guration Parameters PEG Port Configuration Submenu PEG Port Options Feature Options Description Memory RC Version Info only Memory Frequency Info only Total Timings tCL tRCD tRP tRAS Info only Channel...

Page 54: ...u PCI Express Root Port 4 Settings PCI Express Root Port 5 Submenu PCI Express Root Port 5 Settings PCI Express Root Port 11 Submenu PCI Express Root Port 11 Settings PCI Express Root Port 12 Submenu...

Page 55: ...tware Preserve Port 0 Disabled Enabled Enable Disable SATA Port Hot Plug Disabled Enabled Designates this port as Hot Pluggable Serial ATA Port 4 Software Preserve Port 0 Disabled Enabled Enable Disab...

Page 56: ...ature Options Description HD Audio Disabled Enable Auto Control Detection of the HD Audio device Disabled HD Audio will be unconditionally disabled Enabled HD Audio will be unconditionally Enabled Aut...

Page 57: ...Y the User s password is set then this is a power on password and must be entered to boot or enter Setup In Setup the User will have Administra tor rights The password length must be in the following...

Page 58: ...ion Priorities Boot Option 1 Generic Ultra HS COMBO UEFI Built in EFI Shell Disabled Set the system boot order Boot Option 2 Generic Ultra HS COMBO UEFI Built in EFI Shell Disabled Set the system boot...

Page 59: ...tup without saving any changes Save Changes Yes No Save Changes done so far to any of the setup options Discard Changes Yes No Discard Changes done so far to any of the setup options Defaults Options...

Page 60: ...50 This page intentionally left blank...

Page 61: ...voltage and power source settings Z Always install and operate equipment near an easily accessible electrical socket outlet Z Secure the power cord do not place any object on over the power cord Z On...

Page 62: ...52 Important Safety Instructions This page intentionally left blank...

Page 63: ...60 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 600 1189 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel...