Summary of Contents for aTCA-9300

Page 1: ...9300 Dual Intel Xeon E3 1275V2 1225V2 AdvancedTCA Processor Blade User s Manual Manual Revision 1 02 Preliminary Revision Date April 15 2013 Part No 50 1G022 1000 Advance Technologies Automate the Wo...

Page 2: ...e manufacturer In no event will the manufacturer be liable for direct indirect special incidental or consequential damages arising out of the use or inability to use the product or documentation even...

Page 3: ...2 Memory 18 3 1 3 Intel C216 Chipset Overview 18 3 2 Peripherals 19 3 2 1 Reset 19 3 2 2 SMBus Devices 20 3 2 3 GPIO List 21 3 3 I O Interfaces 22 3 3 1 USB 22 3 3 2 VGA Interface 23 3 3 3 Ethernet C...

Page 4: ...Super IO Configuration 56 6 3 6 Serial Port Console Redirection 57 6 3 7 Network Stack 60 6 3 8 CPU PPM Configuration 61 6 4 Chipset Setup 62 6 4 1 PCH IO Configuration 63 6 4 2 System Agent SA Config...

Page 5: ...compliance to the NEBS Level 3 standard design only The robust computing power and reliability of the aTCA 9300 meets the requirements of telecom equipment manufacturers TEMs and network equipment pr...

Page 6: ...6 1 2 Block Diagram...

Page 7: ...nd packing material for inspection by the dealer Obtain authorization before returning any product to ADLINK Check that the following items are included in the package If there are any missing items c...

Page 8: ...iser card Option 9 Two 10GBASE SFP ports on RTM aTCA R6270 R6280 Display Integrated HD Graphics with DirectX 11 Supports up to 1920 x 1440 resolution USB Two USB 2 0 ports on front panel Two USB 2 0 p...

Page 9: ...cal Environmental Dimensions 322 25mm x 280mm x 30 48mm H x D x W 6HP slot Operating Temperature Standard 0 C to 50 C NEBS short term 0 C to 61 C sea level Storage Temperature 40 C to 85 C Humidity 5...

Page 10: ...el HD Graphics P4000 3 Power Supply Chroma DC Power supply 62012P 80 60 4 CPU Single 4 core Intel Xeon processor E3 1275V2 The following table lists power consumption under different operating systems...

Page 11: ...11 2 3 Board Layout 2 3 1 aTCA 9300 Board Layout 1 2 3 4 17 18 20 21 22 23 19 5 6 7 8 14 13 12 11 9 10 15 16 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 53 52...

Page 12: ...r I O 22 BATTERY 23 SPI Socket 24 JP2 GND_SH 25 SW3 BIOS switch 26 SW4 JTAG switch 27 SW5 COM power switch 28 SW6 com IPMC function 29 SW2 RTM Reset switch 30 JTAG Program Header 31 JP1 Clear CMOS 32...

Page 13: ...13 VGA USB GbE RJ 45 RS 232 Serial Port Base and Fabric Channel LEDs Reset Button OOS LED HDD LED USER LED Hotswap LED...

Page 14: ...1 Out of Service OOS LED Out of Service LED Red State Remark Blinking During BIOS POST M4 Off BIOS POST OK M4 On After OS shutdown M1 Hot swap LED Hot swap LED Blue FRU State number FRU State Name Off...

Page 15: ...ink 100 Mbps Green 1Gbps Orange Fabric 2 ACT Green Blink when accessing Ethernet I O BCH2 ACT Green Blink when accessing Ethernet I O Fabric 1 Speed and Link 1Gbps OFF 10Gbps Orange BCH1 Speed and Lin...

Page 16: ...conforms to the following specifications PICMG 3 0 R2 0 ECN0002 AdvancedTCA PICMG 3 1 Ethernet over AdvancedTCA Option 9 NEBS Level 3 design LEFT LED Speed and Link 1Gbps Amber 100Mbps Orange RIGHT LE...

Page 17: ...hnology Enhanced Intel SpeedStep Technology Intel Virtualization Technology Intel VT Intel Hyper Threading Technology Intel HT Technology The Intel Xeon processor E3 1275V2 E3 1225V2 Core i3 3220 has...

Page 18: ...x SATA ports Data transfer rates up to 6 0 Gb s 600 MB s on up to two ports Data transfer rates up to 3 0 Gb s 300 MB s and up to 1 5 Gb s 150 MB s on all ports Integrated AHCI controller Intel Rapid...

Page 19: ...ircuit that detects a drop in voltage below the acceptable operating limit of 4 85V for the 5V line and below 3 2V for the 3 3V line Other reset sources include the Watchdog Timer the face plate push...

Page 20: ...on1 IPMB Zon1 Power AMC_SMbus IPMC Smart Fusion A2F500 RTM_SMbus IPMB A_SMbus IPMB B_SMbus IPMB A_SMbus SMbus_Host Hot Sw ap Buffer ICS9ZX21901 Host_SMbus clock buffer XDP 0x56h PECI 1 1 HOST MAX6618...

Page 21: ...3 3V_SB 3 3V_SB 3 3V_SB 3 3V_SB 3 3V_SB Unused TP 3 3V_SB 3 3V_SB 3 3V_SB 3 3V_SB 3 3V_SB 3 3V 3 3V_SB 3 3V_SB 3 3V_SB 3 3V_SB 3 3V_SB 3 3V_SB 3 3V_SB 3 3V_SB 3 3V 3 3V 3 3V 3 3V 3 3V_SB 3 3V 3 3V 3 3...

Page 22: ...speed capable Hi speed USB 2 0 allows data transfers of up to 480 Mb s 40 times faster than a full speed USB USB 1 1 One USB peripheral may be connected to each port With the aTCA R6270 RTM the aTCA...

Page 23: ...1 and 2 BCH1 BCH2 The aDB 6100 A Fabric riser card is installed on the aTCA 9300 by default and provides support for different configurations of Fabric Channels 1 and 2 Equipped with an Intel 82599EB...

Page 24: ...d Data TxD Out 3 Received Data RxD In 4 Signal Ground 5 Signal Ground 3 3 5 Onboard CFast Interface The aTCA 9300 has one 17 pin CFast connector reserved for onboard mounting of a disk The connecotor...

Page 25: ...t OFF OFF OFF OFF Standalone Mode OFF OFF ON OFF 3 3 6 2 IPMC JTAG Signal The switch SW4 is designed for hardware debug purposes Do not change the default settings Doing may result in an abnormal boot...

Page 26: ...central repository 4 1 IPMI Sensors The following table lists all the sensors supported by the aTCA 9300 Item Sensor Name Sensor Address Description 1 Hot Swap 0x0 FRU Hotswap Sensor 2 AMC Hot Swap 0...

Page 27: ...reshold 0 degrees C Lower Critical Threshold 5 degrees C Lower Non Recoverable Threshold 10 degrees C 13 PSU1 Temp 0xC Temperature Sensor Upper Non Recoverable Threshold 95 degrees C Upper Critical Th...

Page 28: ...U Operational State M7 Communication Lost 6 1b FRU Operational State M6 FRU Deactivation In Progress 5 1b FRU Operational State M5 FRU Deactivation Request 4 1b FRU Operational State M4 FRU Active 3 1...

Page 29: ...uest an update of the sensor status and that update has not occurred yet Software should use this bit to avoid getting an incorrect status while the first sensor update is in progress This bit is only...

Page 30: ...y no action no interrupt Hard Reset Power Down Power Cycle reserved Timer interrupt The Event Data 2 field for this command can be used to provide an event extension code with the following definition...

Page 31: ...ith the following definition Event Data 2 7 0 Version change type 00h unspecified 01h management controller device ID change in one or more fields from Get Device ID 02h management controller firmware...

Page 32: ...a reading state is unavailable because the management controller cannot obtain a valid reading or state for the monitored entity typically because the entity is not present For more in formation plea...

Page 33: ...les Get BMC Global Enables Clear Message Flags Get Message Flags Get Message Send Message Master Write Read BMC Watchdog Timer Reset Watchdog Timer Set Watchdog Timer Get Watchdog Timer Event Commands...

Page 34: ...AdvancedTCA Get PICMG Properties Get Address Info FRU Control FRU Control Capabilities Get FRU LED Properties Get LED Color Capabilities Set FRU LED State Get FRU LED State Set IPMB State Set FRU Act...

Page 35: ...ly with these requirements Exercised due care when handling the board as the heat sink can get very hot Do not touch the heat sink when installing or removing the board The board should not be placed...

Page 36: ...g and Removing the aTCA 9300 5 2 1 Installing the Blade Follow these steps to install the aTCA 9300 blade to the chassis Step 1 Carefully align the board edges with the chassis guide rails and push th...

Page 37: ...oth ends of the module are correctly inserted into the proper openings Push inwards on the handles until the blade is firmly seated in the chassis Do not force the handles if there is any abnormal res...

Page 38: ...38 Step 3 Push the ejector handles inwards until it is locked...

Page 39: ...39 Step 4 Lock both ends of the captive screws...

Page 40: ...40 5 2 2 Removing the Blade Follow these steps to remove the aTCA 9300 blade from the chassis Step 1 Unlock both ends of the captive screws...

Page 41: ...41 Step 2 Pinch the lever and latch together then pull outwards to release the ejector handles at both ends Lever Latch...

Page 42: ...42 Step 3 Pull the blade outwards from the chassis until it is removed...

Page 43: ...I serial terminal This parameter instructs the IPMItool utility to use the serial interface for communications with the carrier IPMC D dev baudrate This parameter specifies the serial device and baud...

Page 44: ...updates the backup BIOS image 2 Make sure the payload power is off M1 state before updating the IPMC firmware 5 3 2 Update over KCS Step1 Prepare an aTCA 9300 with Linux system Enter the following co...

Page 45: ...d Item File name IPMC firmware hpm1fw img BIOS hpm1bios img 5 3 3 Update over LAN The following IPMItool command line parameters are used for communicating with the carrier IPMC via LAN I lan The para...

Page 46: ...nux system Enter the following command At the password prompt just press Enter key Step2 Select y and wait until the string of firmware update procedure successful is displayed To update other images...

Page 47: ...e the setup screen There are several cases that use other keys such as F1 F2 and so on 6 1 1 Setup Menu The main BIOS setup menu is the first screen that you can navigate Each main BIOS setup menu opt...

Page 48: ...IOS setup utility uses a key based navigation system called hot keys Most of the BIOS setup utility hot keys can be used at any time during the setup navigation process These keys include F1 F10 Enter...

Page 49: ...so allow you to display the setup sub screens F1 The F1 key allows you to display the General Help screen Press the F1 key to open the General Help screen F2 The F2 key on your keyboard is the previou...

Page 50: ...ows you to save any changes you have made and exit Setup Press the F4 key to save your changes The following screen will appear Press the Enter key to save the configuration and exit You can also use...

Page 51: ...Main Setup options They are described in this section The Main BIOS Setup screen is shown below 6 2 1 System Board Info The Main BIOS setup screen reports processor memory and board information BIOS...

Page 52: ...left frame of the screen such as Super IO Configuration to go to the sub menu for that item You can display an Advanced BIOS Setup option by highlighting it using the Arrow keys The Advanced BIOS Set...

Page 53: ...circumvent problems with older operating systems When Enabled the processor will limit the maximum CPUID input value to 03h when queried even if the processor supports a higher CPUID input value When...

Page 54: ...below SATA Controller s Enable or disable SATA device SATA Mode Selection The SATA can be configured as a legacy IDE RAID and AHCI mode SATA Controller Speed Indicates the maximum speed the SATA cont...

Page 55: ...USB support Auto option disables legacy support if no USB devices are connected Disable option will keep USB devices available only for EFI applications Set this value to Enable Disable Auto EHCI Han...

Page 56: ...ange the value of the selected option The settings are described on the following pages The screen is shown below Serial Port 1 2 3 Configuration Set Parameters of Serial Port 1 2 3 COM A B C Set this...

Page 57: ...select an item Use the and keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described on the following pages...

Page 58: ...the bits per second you want the serial port to use for console redirection The options are 115200 57600 38400 19200 9600 Data Bits Select the data bits you want the serial port to use for console red...

Page 59: ...eyPad on Putty Set this value to VT100 LINUX XTERMR6 SCO ESCN VT400 Serial Port for Out of Band Management Windows Emergency Management Services EMS The following functions control the presence and co...

Page 60: ...9600 Flow Control Set this option to select Flow Control for console redirection The settings for this value are None and Hardware RTS CTS Data Bits This is a display only function providing informati...

Page 61: ...is option is used for enable Ipv6 PXE boot support If disabled IPV4 PXE boot option will not be created 6 3 8 CPU PPM Configuration Ivybridge PPM configuration parameters An example screen is shown be...

Page 62: ...port Enable or disable CPU C7 ACPI C3 report to OS Set this value to Enable Disable 6 4 Chipset Setup Select the Chipset tab from the setup screen to enter the Chipset BIOS Setup screen You can select...

Page 63: ...h Precision Event Timer chip consists of a 64 bit main counter counting at least at 10MHz and a set of up to 256 comparators HPET is programmed via a memory mapped I O window that is discoverable via...

Page 64: ...SA Configuration VT d The Intel Virtualization Technology for Directed I O Set this value to Enable Disable 6 4 2 2 Memory Configuration Memory Remap Enable or disable memory remap above 4G Set this v...

Page 65: ...hown below Quiet Boot Disabled Set this value to allow the computer system to display the POST messages Enabled Set this value to allow the computer system to display the OEM logo Fast Boot Enables or...

Page 66: ...ROMs to trap interrupt 19 Set Boot Priority Set Boot Option 1 2 boot priority Hard Disk Drive BBS Priorities Specifies the boot device priority sequence from available hard drives CSM Parameter OpROM...

Page 67: ...gacy Video OpROM Set this value to Do not launch UEFI only Legacy only Other PCI device ROM priority For PCI devices other than Network Mass storage or Video defines which OpROM to launch Set this val...

Page 68: ...ay an Exit BIOS Setup option by highlighting it using the Arrow keys The Exit BIOS Setup screen is shown below Save Changes and Reset Reset the system after saving the changes Discard Changes and Rese...

Page 69: ...ar to any of the setup options Restore Defaults Restore Load Defaults values for all the setup options Save as User Defaults Save the changes done so far as user defaults Restore User Defaults Restore...

Page 70: ...rface to communicate with BMC FRB 2 Timer timeout It can select the value between 1 to 4 min for FRB 2 timer expiration value OS Watchdog Timer If enabled starts a BIOS timer which can only be shut of...

Page 71: ...user IDs for SOL You can refer to the following sections for more detailed information Note SOL does not support simultaneous login of more than one user 7 1 Preparation For SOL Connection First of al...

Page 72: ...on COM2 only 7 3 2 Linux grub Setting GRUB supports sending its messages to the serial console The following lines should be added to the top of the boot grub grub conf file default 1 timeout 5 seria...

Page 73: ...the following table for the Cipher Suite Id ID characteristics Cipher Suite Authentication Algorithm Integrity Algorithm s Confidentiality Algorithm s 0 straight password 00h 00h 00h RAKP none None No...

Page 74: ...blish the SOL session via channel 5 with default user name and password Sample Establish a non encrypted RMCP SOL session ipmitool I lanplus H 172 17 172 134 C 0 U adlinkuser P adlinkuser sol activate...

Page 75: ...Please visit the aTCA 9300 product web site for more details http www adlinktech com PD web PD_detail php cKind pid 1111 We recommend using all the drivers provided on the ADLINK website to ensure dri...

Page 76: ...ent should be noted 10 If the equipment is not use for long time disconnect the equipment from mains to avoid being damaged by transient overvoltage 11 Never pour any liquid into openings this could c...

Page 77: ...d Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology Beijing Address 1 E 801 100085 Rm 801 Power Creati...

Page 78: ...Korean Liaison Office Address 1675 12 8 8F Mointer B D 1675 12 Seocho Dong Seocho Gu Seoul 137 070 Korea Tel 82 2 2057 0565 Fax 82 2 2057 0563 Email korea adlinktech com ADLINK Technology Singapore P...