Page 6
Electrical requirements (Cont.)
1.
The wire coloured green and yellow
must be connected to the
terminal in the plug, which is marked by the letter E, or by the
safety earth symbol coloured green, or green and yellow.
2.
The wire, coloured blue
must be connected to the terminal
which is marked with the letter N, or coloured black.
3.
The wire, coloured brown
must be connected to the terminal
which is marked with the letter L, or coloured red.
NOTE:
A competent service engineer must carry out any replacement of
the mains cable
.
HEATING ELEMENT:
The heating element
fitted to this press is rated at 280Watts / 230V
AC/ 110 V AC.
Never connect
to any outlet or power supply having a different
voltage/frequency from that on the machine data plate.
2.4
Adjusting the pressure
This press is fitted
with a red or black pressure adjustment knob
located on the machine:
a)
To increase pressure
or to use smaller diameter mugs turn
knob clockwise.
b)
To decrease pressure
or to print onto larger diameter mugs,
(within the stated range), turn the adjustment knob
anticlockwise.
c)
Be careful
when placing mug in press that pressure jaws are
not in contact with Mug handle as this may cause damage.
NOTE:
DO NOT adjust the pressure when the machine is clamped shut.
CAUTION:
Never increase the pressure to the extent of requiring undue force
to lower the operating handle into the lock position, as this will
place excessive stress on the heater band, resulting in damage to the
press.
Please refer to Page 13 showing the operation of the control unit.