background image

 

 

                                                     

Page 2 

1.2 

Safety Tips 

 
 
 

 

Our  customer  service

 

department

  has  its  own  service 

engineers and, if required, maintenance is available.  

 

 

The Studio 

'EZ'

-

Auto Clam 

meets the European Legislation 

standard.    Under  normal  conditions  accidents  are  rare.  
However listed below are some practical points to ensure your 
safety. 

 

 

This  press  will  automatically  open  when  the  transfer 
cycle  is  complete.

  Make  sure  there  is  sufficient  space 

around  the  machine  for  the  heat  plate  to  rise  from  the 
table,  without  interference. 

Only  persons  fully  trained 

should operate this machine.

 

 

 

Always  switch  off

  the  current  (and  pull  plug  out  of  the 

socket)  when  undertaking  maintenance  work  or  when 
cleaning the machine. 

 

 

Ensure that there is

 sufficient space around the machine.  

Cables  and  connections  must  not  get  jammed.    Although 
the  heat  radiation  of  the  press  is  low,  there  should  be 
enough space for cooling down. 

 

 

Avoid contact

 with the heat plate. 

 

 

DO  NOT  REMOVE  THE  INSTRUMENT  COVER 
UNLESS QUALIFIED TO DO SO

 - touching internal parts 

is  dangerous  and  may  cause  shock  hazard.  All  electrical 
connections  inside  covers  are  live.    Never  operate  Press  with 
any covers and/or guards removed. 

 

 

PROTECT  THE  MAINS  CABLE

  -  damage  to  the  mains 

cable may cause fire or shock hazard.  When unplugging, hold 
by  the  plug  only  and  remove  carefully.    Take  care  that  the 
mains cable does not come into contact with the heat plate (or 
moving  parts  of  the  mechanism)  during  operation  of  the 
machine. 

 

 

OPERATING AMBIENT TEMPERATURE RANGE

 

the 

operating  ambient  temperature  range  is  0

o

C  -  35

o

C, 

(32

o

F - 

104

o

F)

 and humidity of 20% - 80%.  

 

 

MACHINE  FUSES

  - 

Studio 

'EZ'

-

Auto  Clam 

13  Amps  (3 

pin plug only). 

 

 

WARNING  -  THIS  APPARATUS  MUST  BE  EARTHED 
(GROUNDED) 

 

 

CAUTION 

This machine gets hot whilst operating.  Take care not to touch 
any surfaces that are labelled “Caution this plate is HOT”. 

 

Summary of Contents for STUDIO EZ AUTO CLAM

Page 1: ...h EC safety regulations STUDIO EZ AUTO CLAM 2018 A Adkins Sons Ltd All rights reserved E OE V1 0 All products within the ADKINS range are labelled with CE marking and are manufactured and tested to co...

Page 2: ...signed and manufactured to ensure that you the user will gain the maximum benefit All A Adkins Sons Limited products are specifically designed to ensure ease of use with particular attention to safety...

Page 3: ...with the Studio EZ Auto Clam 6 3 2 Working with heat transfer materials 6 3 3 Pressing pad assembly 7 3 4 Shutting down the machine 7 3 5 Auto shut down feature 7 4 Maintenance of the Machine 8 4 1 Da...

Page 4: ...40 x 50 cm 15 75 x 19 7 in Specifications Power consumption 1 8 kW Power supply 230 Volts AC Max Working temperature 225o C 437 o F Display Timer Range 0 480 sec Machine height open 90 cm 35 5 in Mac...

Page 5: ...at radiation of the press is low there should be enough space for cooling down Avoid contact with the heat plate DO NOT REMOVE THE INSTRUMENT COVER UNLESS QUALIFIED TO DO SO touching internal parts is...

Page 6: ...s trained to do so should operate this machine This is very important because the machine when set will open automatically after the transfer cycle is complete There must be sufficient space for the h...

Page 7: ...ion Ensure that no items vulnerable to heat radiation are too close to the machine 2 2 4 Remove the transit screw that secures the handle in the down position The screw is located in the centre of the...

Page 8: ...io EZ Auto Clam is rated at 1 8 kW Never connect to any outlet or power supply having a different voltage frequency from that on the machine data plate 2 4 Adjusting the pressure This press is fitted...

Page 9: ...ansfer paper that the material to be used is suitable for and has been prepared for transfer printing 3 2 1 Close the press to check the amount of closing pressure the machine has been set at If more...

Page 10: ...h would tend to cut the pressing pad i e buttons pins press studs or zips Never allow the hot heat plate to rest on the pressing pad when the press is not being used as the pad may be damaged IMPORTAN...

Page 11: ...with a dry cloth before use when the plate is cold 4 2 Periodic Maintenance Put a few drops of oil onto the various pivot pins and the pressure adjusting screw every three months 4 3 Cleaning Clean t...

Page 12: ...agrams On the following pages are the schematic diagrams for the Studio EZ Auto Clam 5 1 General Layout Page 10 5 2 Control Unit Operation Page 11 5 3 Exploded diagram and parts list Page 12 5 4 Machi...

Page 13: ...MACHINE OPERATING HANDLE TIME AND TEMPERATURE CONTROLLER PRESSURE ADJUSTING KNOB TABLE AND PAD HEAT PLATE 5 1 General Layout Page 10...

Page 14: ...material being used Press the OK button to turn the SV light and temperature settings digits off 1 2 3 4 5 6 Press the OK button three times to enter the time setting mode the SV and time settings li...

Page 15: ...ing 2 Part 1 OMC750 8 17 Magnetic Switch 1 STEZA 17 18 Electronic Case 1 STEZA 18 19 Back Plate of Electronic Case 1 STEZA 19 20 Circuit Breaker 1 STEZA 20 21 Power Cord 1 STEZA 21 22 Rocker Switch 1...

Page 16: ...USEYW BK R GN EH1 EH2 A 12 11 10 9 8 RED INDICATOR 7 6 5 4 3 2 1 B SOLID STATE RELAY DIGITAL CONTROLLER GY 06 RECTIFYING BOX TRANSFORMER ELECTROMAGNET CYCLE RELEASE BUTTON MAGNETIC SWITCH HEAT PLATE 1...

Page 17: ...ant improvement and or modification to meet changing conditions the right is reserved to change the design and or specifications at any time without prior notification and therefore specifications may...

Page 18: ...a replacement press the warranty of the replacement press shall expire on the anniversary date of the original machines invoice to the customer In order for this warranty to be effective no return of...

Page 19: ...es BS EN ISO 13850 2015 Safety of Machinery Emergency Stops BS EN ISO 141211 2007 Safety of Machinery Principles for Risk Assessment BS EN 55011 2016 A1 2017 Class A Group 2 Equipment EMC Emissions BS...

Reviews: