To reduce the risk of electrical shock or fire, do not expose this unit rain or moisture
Do not spill water or other liquids into or on to your unit.
Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt
to remove or break off the ground prong from the electrical cord. This prong is used to reduce the
risk of electrical shock and fire in case of an internal short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user serviceable parts inside.
Never operate this unit when it’s cover is removed.
Never plug this unit in to a dimmer pack
Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm)
between this device and a wall.
Do not attempt to operate this unit, if it becomes damaged.
This unit is intended for indoor use only, use of this product out`
doors voids all warranties.
During long periods of non-use, disconnect the unit’s main power.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to be walked on or pinched by
items placed upon or against them, paying particular attention to the point they exit from the unit.
Note: Please make sure the power off before any installation, repair and clean
Features
Warm up time: 5 min
Output:10,000 CFM
Tank Capacity: 1.5 US Liters
Fuse: 10A/125V
Heater: 1250W
IP Grade: IP20
Power Supply: AC 110V/60Hz
Fixture Size: 16 in × 8 in × 8 in
Weight: 6.2lb(1pc/CTN)
Operation
Place fog machine on a level flat surface, remove fog liquid tank cap. Fill with Adkins Lighting Brand Fog Fluid. Lower quality
fluid can damage the unit. When filled, place cap back on liquid tank.
Firmly attach remote control cable to the proper input on the rear of the machine.
Plug the power cord into a grounded electrical outlet. If necessary, turn power switch on rear of unit to “1” position. Warm-up
is complete when the LED on trigger unit illuminates.
To emit fog, press the remote control button for the desired length of time.
The trigger’s LED will cycle on and off as the machine re-heats to the proper operating temperature.
Important:
Monitor tank fluid level as you are fogging, running a fog machine with no fluid can permanently damage the unit.
If output is low, pump is noisy or there is no output at all, unplug immediately. Check fluid level, external fuse, remote