ADJ WiFly Par QA5 WH User Instructions Download Page 5

ADJ Products, LLC  -  www.adj.com  - WiFly Par QA5 WH User Manual Page 9

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

  WiFly Par QA5 WH 

                                          Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

ADJ Products, LLC  -  www.adj.com  - WiFly Par QA5 WH User Manual Page 8

Power Supply:

 The ADJ WiFly Par QA5 WH contains a automatic 

voltage switch, which will auto sense the voltage when it is plugged 

into the power source. With this switch there is no need to worry about 

the correct power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The WiFly Par QA5 WH can be controlled via DMX-512 protocol. The 

WiFly Par QA5 WH has 8 DMX channel modes, please see page 12-13 

for the different modes. The DMX address is set on the back panel of the 

WiFly Par QA5 WH. Your unit and your DMX controller require a stan-

dard 3-pin or 5-pin XLR connector for data input 

and data output (Figure 1). We recommend Accu-

Cable DMX cables. If you are making your own 

cables,  be  sure  to  use  standard  110-120  Ohm 

shielded cable (This cable may be purchased at 

almost all pro lighting stores). Your cables should 

be made with a male and female XLR connector 

on either end of the cable. Also remember that 

DMX cable must be daisy chained and cannot be 

split.

  WiFly Par QA5 WH                                                   Set Up

Figure 1

Summary of Contents for WiFly Par QA5 WH

Page 1: ...brands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equi...

Page 2: ...QA5 WH Installation WiFly Par QA5 WH Introduction ADJ Products LLC www adj com WiFly Par QA5 WH User Manual Page 2 Unpacking Thank you for purchasing the WiFly Par QA5 WH by ADJ Products LLC Every WiF...

Page 3: ...this unit rain or moisture Do not spill water or other liquids into or on to your unit Do not attempt to operate this unit if the power cord hasbeen frayed or broken Do not attempt to remove or break...

Page 4: ...cement please contact ADJ customer support 800 322 6337 3 7 Do Not use a damaged Battery The battery could be damaged during shipping caused by shock Should the battery be found damaged including dam...

Page 5: ...Use Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 Pin XLR to 5 Pin XLR Conversion ADJ Products LLC www adj com WiFly Par QA5 WH Use...

Page 6: ...DOWN buttons to scroll through the different Auto Fade modes AJXX Color Change mode there are 16 Color Change modes to WiFly Par QA5 WH Operating Instructions Operating Power There are two ways to su...

Page 7: ...t ADJ Products LLC www adj com WiFly Par QA5 WH User Manual Page 12 WiFly Par QA5 WH Operating Instructions choose from Use the UP or DOWN buttons to scroll through the different Auto Change modes A J...

Page 8: ...r 1 Plug the fixture in and press the MODE button until rCXX is dis played XX represents a number between 00 14 2 Press the UP or DOWN buttons to either activate the remote func tion On or deactivate...

Page 9: ...te speed of the Auto Run mode Auto Run program selection sound sensitivity and color select WiFly Par QA5 WH WiFly Set Up WiFly Par QA5 WH WiFly Master Slave Set Up With this feature you are able to c...

Page 10: ...Functions Channel Value Function 1 COLOR MACROS 0 15 OFF 16 31 RED 32 47 GREEN 48 63 BLUE 64 79 AMBER 80 95 RED GREEN 96 111 RED BLUE 112 127 RED AMBER 128 143 GREEN BLUE 144 159 GREEN AMBER 160 175...

Page 11: ...l DMX mode for colors WiFly Par QA5 WH 7 Channel DMX Values Functions Channels 1 2 3 and 4 will not work when Channel 7 is being used Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLU...

Page 12: ...Channel 7 is between the values of 154 204 Channel 8 is in Color Fade Mode and Channel 6 will control the color fade speed When Channel 7 is between the values of 205 255 Channel 8 is in Sound Active...

Page 13: ...yed it means the battery is dead or you are running the unit on AC power Please do not let the battery fully die this severly shortens the life of the battery Example If b050 is displayed the battery...

Page 14: ...aneously release all four buttons The unit should display that last running mode This indi cates that the unit has entered initialization mode successfully Note When the four buttons have not been pre...

Page 15: ...se and replace with a new one The fuse holder also has a holder for a spare fuse WiFly Par QA5 WH Fuse Replacement WiFly Par QA5 WH Modify the Battery Capacity After replacing either the PCB or the ba...

Page 16: ...r inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to purc...

Reviews: