background image

21

MAIN MENU

OPTIONS / VALUES (Default Settings in BOLD)

DESCRIPTION

Information

Fixture Life Time

Power On Time

xxxxxx Hours

Total hrs. fixture powered ON. Cannot be 

reset.

P-On Time-R

xxxxxx Hours

Hours fixture powered ON. Can be reset

P-On Time Reset Passcode 

Reset Power On Time (Passcode = 050)

Total LED Time

LED On Time

xxxxxx Hours

Resets to 0 when lamp replaced and reset

(Passcode = 050)

LED On Time-R

xxxxxx Hours

LED On Time Reset Passcode 

Fixture Temps

LEDs

Current

xxx F°/

xxx C°

Current temperature in Farenheit and 

Celsius

Max 

Resettable

xxx F°/

xxx C°

Current maximum temperature since last 

reset. Can be reset as needed by user.

Max Not 

Resettable

xxx F°/

xxx C°

Maximum temperature fixture reached. 

Cannot be reset

Reset LED Temp

YES / NO Passcode

Shall allow for Head Temperature data to 

be reset. Should be Passcode protected 

(Passcode = 050).

Fan Info.(RPM) Base Fan XXXX

xxxx

Displays fan RPM

LED Fan XXXX

xxxx

DMX Values

Pan

Displays current DMX Channel value of 

respective fixture trait.

Tilt

...

Zoom

Error Logs

Fixture Errors

List Errors one by 

one

Displays Fixture Errors

Reset Error Log

YES / NO

Reset Error Log (Passcode = 050)

Max Temp LED 

ON

32~167°F, 118°F / 0~75°C, 48°C

High Temp LED 

OFF

169°F, 117°F / 76°C, 47°C

Software Version X.XX

S Y S T E M   M E N U

Summary of Contents for VIZI WASH Z19

Page 1: ...ADJ VIZI WASH Z19 User Manual...

Page 2: ...rigging and operation of this product ADJ PRODUCTS LLC World Headquarters 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 800 322 6337 Fax 323 582 2941 www adj com support adj com ADJ Supply Europe B...

Page 3: ...lines 9 Fixture Overview 10 Color Macro Chart 11 Installation Guidelines 12 DMX Set Up 15 DMX Addressing 16 System Menu 17 Pixel Zone Layout 25 Target Modes 26 Dimmer Mode Graphs 27 DMX Traits Channel...

Page 4: ...ns Please do not return this device to your dealer without first contacting customer support Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Omega...

Page 5: ...repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof includ...

Page 6: ...IS UNIT DONOTATTEMPTANYREPAIRSYOURSELF DOINGSOWILLVOIDYOURMANUFACTURER S WARRANTY DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THI...

Page 7: ...between fixture and other devices or a wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm and always install fixtu...

Page 8: ...s iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there is no...

Page 9: ...ing normal operation resulting in damage or injury as larger parts could fall Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Def...

Page 10: ...10 FIXTURE O VERVI EW...

Page 11: ...3 Color Macro 47 185 188 0 142 208 0 Color Macro 15 57 60 255 96 236 96 Color Macro 48 189 192 52 148 209 0 Color Macro 16 61 64 238 93 255 93 Color Macro 49 193 196 1 134 204 0 Color Macro 17 65 68 1...

Page 12: ...he metal truss structure or surface is properly certified to safely hold the combined weight of the fixture s clamps cables and accessories Fixture ambient operating temperature range is 0 to 104 F 0...

Page 13: ...TION When mounting fixture to truss be sure to secure an appropriately rated professional grade rigging clamp to the included Omega Brackets using an M12 screw fitted through the center hole of the Om...

Page 14: ...allation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation...

Page 15: ...in Data Cable DMX Cable Requirements For DMX Operation The Focus Flex can be controlled via DMX 512 protocol Your unit and your DMX controller requires a 5 pin XLR connector for data input output We r...

Page 16: ...to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to list...

Page 17: ...main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP and DOWN buttons When you reach a field that requires adjusting press the ENTER b...

Page 18: ...n signal is lost Personality Status Settings Pan Invert ON OFF Tilt Invert ON OFF P T Feedback ON OFF P T Speed Speed 1 Speed 2 Speed 1 Default should allow unit to move at its fastest possible speed...

Page 19: ...255 White7 125 255 USB Port Power ON OFF Update Software YES NO Factory Restore YES NO When YES is selected enter password password 11 to reset the fixture to factory settings Manual Control Pan 000 2...

Page 20: ...t program based on this fade setting 000 being NO fade and 255 being maximum fade Program 2 Speed 000 255 Shall run the set program based on this speed setting 000 being slowest and 255 being the fast...

Page 21: ...elsius Max Resettable xxx F xxx C Current maximum temperature since last reset Can be reset as needed by user Max Not Resettable xxx F xxx C Maximum temperature fixture reached Cannot be reset Reset L...

Page 22: ...If DMX signal stops fixture continues to obey the last command it received Via DMX Int Pro Blackout fixture blacks out if DMX signal stops or Manual If DMX signal stops fixture returns all channels to...

Page 23: ...s Select Reset Motors and press ENTER button to confirm Use UP DOWN buttons to select Pan Tilt Effect or All and press ENTER button to store Display Select Display and press ENTER button to confirm Us...

Page 24: ...to confirm Use UP DOWN buttons to select Power On Time P On Time R or P On Time Reset and press ENTER button to store Total LED Time Select Total LED Time and press ENTER button to confirm Use UP DOW...

Page 25: ...25 PIXEL ZO NE L AYO UT Pixel Zone Layout 28 Ch Mode 29 Ch Mode w Software Version 1 6 Pixel Zone Layout 44 Ch Mode 45 Ch Mode w Software Version 1 6...

Page 26: ...26 TARGET MO DES...

Page 27: ...27 DIMMER MO DE G RAPH S...

Page 28: ...0 100 13 13 13 13 000 255 Red3 Dimmer 0 100 14 14 14 14 000 255 Green3 Dimmer 0 100 15 15 15 15 000 255 Blue3 Dimmer 0 100 16 16 16 16 000 255 White3 Dimmer 0 100 17 17 000 255 Red4 Dimmer 0 100 18 1...

Page 29: ...9 Shutter 000 019 Blackout 020 024 Open 025 064 Strobe Slow to Fast 065 069 Open 070 084 Pulse Slow Open Fast Closed 085 089 Open 090 104 Pulse Fast Open Slow Closed 105 109 Open 110 124 Random Strob...

Page 30: ...7 27 43 43 Dim Modes 000 020 Default to Unit Setting 021 040 Standard 041 060 Stage 061 080 TV 081 100 Architectural 101 120 Theatre 121 140 Stage 2 141 160 Dim Speed from Fast to Slow 0 1 10s 161 255...

Page 31: ...eset Error Tilt Reset Error Tilt Endcoder Error Tilt Encoder Error LED Fan start errors LED Fan Cannot Start LED Fan stop errors Tilt Encoder Error LED Fan fast speed Led Fan Cannot Start LED Fan slow...

Page 32: ...X Channel Modes 13 14 17 18 29 30 45 46 64 built in Color Macros Color display with touch buttons 3 or 7 zones of LED ring control Smooth 0 100 Dimming Fine 16 bit Dimming 6 Dimmer Curve modes Fine 16...

Page 33: ...33 DIMENSIO NS DRAWINGS NOT TO SCALE DIMENSIONS FOR INFORMATION ONLY AND SUBJECT TO CHANGE WITHOUT NOTICE...

Page 34: ...erence to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television recepti...

Page 35: ......

Reviews: