21
MAIN MENU
OPTIONS / VALUES (Default Settings in BOLD)
DESCRIPTION
Information
Fixture Life Time
Power On Time
xxxxxx Hours
Total hrs. fixture powered ON. Cannot be
reset.
P-On Time-R
xxxxxx Hours
Hours fixture powered ON. Can be reset
P-On Time Reset Passcode
Reset Power On Time (Passcode = 050)
Total LED Time
LED On Time
xxxxxx Hours
Resets to 0 when lamp replaced and reset
(Passcode = 050)
LED On Time-R
xxxxxx Hours
LED On Time Reset Passcode
Fixture Temps
LEDs
Current
xxx F°/
xxx C°
Current temperature in Farenheit and
Celsius
Max
Resettable
xxx F°/
xxx C°
Current maximum temperature since last
reset. Can be reset as needed by user.
Max Not
Resettable
xxx F°/
xxx C°
Maximum temperature fixture reached.
Cannot be reset
Reset LED Temp
YES / NO Passcode
Shall allow for Head Temperature data to
be reset. Should be Passcode protected
(Passcode = 050).
Fan Info.(RPM) Base Fan XXXX
xxxx
Displays fan RPM
LED Fan XXXX
xxxx
DMX Values
Pan
Displays current DMX Channel value of
respective fixture trait.
Tilt
...
Zoom
Error Logs
Fixture Errors
List Errors one by
one
Displays Fixture Errors
Reset Error Log
YES / NO
Reset Error Log (Passcode = 050)
Max Temp LED
ON
32~167°F, 118°F / 0~75°C, 48°C
High Temp LED
OFF
169°F, 117°F / 76°C, 47°C
Software Version X.XX