ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 11
Vizi CMY300
DMX Addressing
DMX ADDRESSING
All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture
responds to the correct control signal. This digital starting address is the channel number from which
the fixture starts to “listen” to the digital control signal sent out from the DMX controller. The assignment
of this starting DMX address is achieved by setting the correct DMX address on the digital control
display on the fixture.
You can set the same starting address for all fixtures or a group of fixtures, or set different addresses
for each individual fixture. Setting all fixtures to the same DMX address will cause all fixtures to react
in the same way, in other words, changing the settings of one channel will affect all the fixtures
simultaneously.
If you set each fixture to a different DMX address, each unit will start to “listen” to the channel number
you have set, based on the quantity of DMX channels of each fixture. That means changing the settings
of one channel will only affect the selected fixture.
In the case of the Vizi CMY300, when in 24 Channel you should set the starting DMX address of the
first unit to 1, the second unit to 25 (24 + 1), the third unit to 49 (25 + 24), and so on. (See chart below
for more details.)
Channel mode
Unit 1
Address
Unit 2
Address
Unit 3
Address
Unit 4
Address
24 channels
1
25
49
73
26 channels
1
27
53
79
38 channels
1
39
77
115