Power Supply: Before plugging your unit in, be sure the source voltage in your area matches the 

required voltage for your device. The VF Snow Flurry HO is available in 120v and 220v versions. 

Because line voltage may vary from venue to venue, it is important to verify that your unit voltage 

matches the wall outlet voltage before attempting to operate your fixture.

DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and 

controller manufacturers as a form of communication between intelligent fixtures and controllers. A 

DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as 

serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals locat-

ed on all DMX fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: DMX is a language allowing all makes and models of different manufacturers to be 

linked together and operate from a single controller, as long as all fixtures and the controller are DMX 

compliant. To ensure proper DMX data transmission, try to use the shortest cable path possible 

when linking several DMX fixtures. The order in which fixtures are connected in a DMX line does not 

influence the DMX addressing. For example, a fixture assigned a DMX address of 1 may be placed 

anywhere in a DMX line: at the beginning, at the end, or anywhere in the middle. Therefore, the first 

fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned 

a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no 

matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation): This device can be controlled via 

DMX-512 protocol, and it is a 1 channel DMX unit. The DMX address is set using the dipswitches on 

the rear panel of the unit. Your unit and your DMX controller require approved DMX-512 110 Ohm 

Data cables for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If 

you are making your own cables, be sure to use standard 110-120 Ohm shielded cable, which may 

be purchased at almost all professional sound and lighting stores. Your cables should be made with 

a male XLR connector at one end and a female XLR connector at the other. Also remember that DMX 

cable must be daisy chained and cannot be split.

 

 

DMX SET UP

Figure 1

Summary of Contents for VF SNOW FLURRY HO

Page 1: ...User Manual VF SNOW FLURRY HO Rev 04 12 2022...

Page 2: ...names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby disclaim any and all liabilities for property equipment building and el...

Page 3: ...s on the web at www adj com for any comments or suggestions Service Hours are Monday through Friday 8 00 a m to 4 30 p m Pacific Standard Time Voice 323 582 2650 Fax 323 582 2941 E mail support adj co...

Page 4: ...s at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Product...

Page 5: ...of pur chase invoice You may obtain an R A number by contacting our customer support number This device features a snow juice level sensor When the snow juice level begins to run low a built in senso...

Page 6: ...d has been frayed or broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in the event of an intern...

Page 7: ...the shortest cable path possible when linking several DMX fixtures The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX ad...

Page 8: ...h is connected between pins 2 and 3 of a male connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cable ter min...

Page 9: ...snow juice only then replace the reservoir 4 Place the feeder tube with the filter deep inside the reservoir and tighten the cap 5 Using the switch on the rear of the unit set the air volume output to...

Page 10: ...desired address and press ENTER to confirm 2 Alternately you can set the DMX address first using the UP or DOWN buttons then press EN TER The address you have set will be the saved address and will a...

Page 11: ...se of failure in snow fog and haze machines Only ADJ Snow Juice is recommended for use with this device Timer Remote Operation Connect the remote to the fog machine The timer function allows fog to be...

Page 12: ...uire service Please contact customer support for further instructions Please do not return the unit to your dealer without contacting customer support first TROUBLE SHOOTING Store your device only in...

Page 13: ...mm H Fuse 15A 110V 10A 220V Tank Capacity 2 3 Liters Spray Distance 8 10 Meters Fluid Type ADJ snow juice Warm Up Time No warm up time Duty Cycle Not to exceed 6 hours powered on SPECIFICATIONS ADJ Pr...

Page 14: ......

Reviews: