ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 8
ADJ Products, LLC - www.adj.com - UV Flood 36 Instruction Manual Page 9
Sound Active Mode:
In this mode the UV Flood 36 will react to sound, and chase through
the different colors.
1. Plug the fixture in and press the MODE button until “SoXX” is
displayed. “XX” represents the sound sensitivity level. Use the UP
and DOWN buttons to adjust the sensitivity. “00” is the lowest
sensitivity, “30” is the highest.
Dimming Curve:
This is used to set the dimming curve used with DMX mode. See
page 11 for the dimming curves diagram.
1. Plug the fixture in and press the MODE button until the DMX
address is displayed.
2. Press the ENTER button until “dCXX” is displayed. This is the
dimmer setting. “XX” represents the current dimming mode.
3. Use the UP and DOWN buttons to find your desired dimmer
curve. Press SET UP when you are finished.
• dC00 - Standard
• dC01 - Stage
• dC02 - TV
• dC03 - Architectural
• dC04 - Theater
DMX State:
This mode is used as a precaution mode, that in case the DMX signal
is lost, the operating mode chosen in this setup is the running mode
the fixture will go into when the DMX signal is lost. You can also set this
as the operating mode you would like the unit to return to when power
is applied.
1. Press the MODE button until the DMX address is displayed. Press
the ENTER button until either “Soun”, “HOLd”, or “blC” is dis-
played.
2. Use the UP or DOWN buttons to find the mode you want incase
of power loss or DMX loss.
• “blC” (Blackout) - If the DMX signal is lost or interrupted, the unit will
automatically go into stand by mode.
UV Flood 36 Operating Instructions
• “HOLd” (Last State) - If the DMX signal is lost or interrupted, the fix-
ture will stay in the last DMX set up. If power is applied and this mode
is set, the unit will automatically go into the last DMX set up.
• “Soun” (Sound Active) - If the DMX signal is lost or interrupted, the
unit will automatically go into sound active mode.
3. Find your desired setting and press ENTER. Your setting will be
saved automatically.
Activate RF Control:
This function is used to activate and deactivate the RF Remote
Control. When this function is activated you can control the fixture
using the Dotz Par RF remote. Please see the next page for remote
controls and functions.
1. Plug the fixture in and press the MODE button until “rFXX” is dis-
played. “XX” represents either “on” or “oFF”.
2. Press the UP or DOWN buttons to either activate the remote func-
tion (On) or deactivate it (Off).
UV Flood 36 Operating Instructions
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-
Slave mode. In Master-Slave configuration one unit will act as the
controlling unit and the others will react to the controlling units built-in
programs. Any unit can act as a Master or as a Slave however, only
one unit can be programmed to act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the
unit. Use standard XLR microphone cables to link your units to-
gether. Remember that the Male XLR connector is the input and
the Female XLR connector is the output. The first unit in the
chain (master) will use the female XLR connector only. The last
unit in the chain will use the male XLR connector only.
2. Using the Master unit, choose your desired operating mode and
connect the “Slave” unit or units.
3. On the “Slave” unit(s) press the MODE button until a “SLAV” is
displayed. They will now follow the “Master” unit.
UV Flood 36 Master-Slave Configuration