ADJ PROFILE PANEL RGBA User Instructions Download Page 3

P

ower Supply:

 The ADJ Profile Panel RGBA contains an electronic 

voltage switch, which will auto sense the voltage when it is plugged 

into  the  power  source.  With  the  voltage  switch  you  do  not  need  to 

worry about wall voltage, this unit can be plugged in anywhere. Also be 

sure to only use the included powerCON cable supplied with the unit. 

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Profile Panel RGBA has 4 DMX channel modes. The DMX address 

is set on the back panel of the Profile Panel RGBA. Your unit and your 

DMX controller require a approved DMX-512 110 Ohm Data cable for 

data  input  and  data  output  (Figure  1).  We  recommend  Accu-Cable 

DMX cables. If you are making your own cables, 

be sure to use standard 110-120 Ohm shielded 

cable  (This  cable  may  be  purchased  at  almost 

all professional sound and lighting stores). Your 

cables should be made with a male and female 

XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained 

and cannot be split.

ADJ Products, LLC  -  www.adj.com  - Profile Panel RGBA User Manual Page 5

  Profile Panel RGBA                                          DMX Set Up

ADJ Products, LLC  -  www.adj.com  - Profile Panel RGBA User Manual Page 6

Figure 1

  Profile Panel RGBA                              Safety Precautions

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids  into or on to your unit.

•   Be sure that the local power outlet match that of the required volt- 

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 4 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the fixture.

    C. The fixture has been exposed to rain or water.

    D. The fixture does not appear to operate normally or exhibits a  

         marked change in performance.

Summary of Contents for PROFILE PANEL RGBA

Page 1: ...d all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indi rect economic loss associated with...

Page 2: ...packing Thank you for purchasing the Profile Panel RGBA by ADJ Products LLC Every Profile Panel RGBA has been thoroughly tested and has been shipped in perfect operating condition Carefully check the...

Page 3: ...on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split ADJ Products LLC www adj com Profile Panel RGBA User Manual Page 5 Profile Panel RGBA DMX Set Up ADJ P...

Page 4: ...cause a short circuit and erratic behavior Profile Panel RGBA DMX Set Up DMX512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE C...

Page 5: ...ed press SET UP if you wish to activate the Flash mode 4 FS XX will now be displayed this is Flash mode The Flash can be adjusted between FS00 flash off to FS15 fastest flash Profile Panel RGBA Operat...

Page 6: ...scroll through the 7 colors Static Color Mode 1 Plug the fixture in and press the MODE button until CLXX is displayed 2 There are 47 colors to choose from Select your desired color by pressing the UP...

Page 7: ...your iOS phone or tablet and aim the transmitter at the fixture sensor and be no more than 15 feet away The app is a free download from the app store for your iOS phone or tablet The app comes with 3...

Page 8: ...nued on the next page Profile Panel RGBA 4 Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 Profile Panel RGBA 7 Channel Mode Channel Va...

Page 9: ...M 1 26 35 PROGRAM 2 36 45 PROGRAM 3 46 55 PROGRAM 4 56 65 PROGRAM 5 66 75 PROGRAM 6 76 85 PROGRAM 7 86 95 PROGRAM 8 96 105 PROGRAM 9 106 115 PROGRAM 10 116 125 PROGRAM 11 126 135 PROGRAM 12 136 145 PR...

Page 10: ...ON 7 0 255 0 100 29 RED SECTION 8 0 255 0 100 30 GREEN SECTION 8 0 255 0 100 31 BLUE SECTION 8 0 255 0 100 32 AMBER SECTION 8 0 255 0 100 See Page 21 for the Section Layout Profile Panel RGBA 32 Chann...

Page 11: ...lor14 81 85 0 255 255 255 Color38 Color15 86 90 255 0 255 255 Color39 Color16 91 95 255 255 255 255 Color40 Color17 96 100 255 206 143 0 Color41 Color18 101 105 254 177 153 0 Color42 Color19 106 110 2...

Page 12: ...0 129 184 0 Color37 196 200 0 83 115 0 Color38 201 205 0 97 166 0 Color39 206 210 1 100 167 0 Color40 211 215 0 40 86 0 Color41 216 220 209 219 182 0 Color42 221 225 42 165 85 0 Color43 226 230 0 46...

Page 13: ...the powerCON input and output sockets The quantity fixtures that can be connected is 20 120V and 35 240V maxi mum After the maximum connected fixtures you will need to use a new power outlet NOTE USE...

Page 14: ...Products LLC factory unless prior written authorization was issued to purchaser by ADJ Products LLC if the product is damaged because not properly maintained as set forth in the instruction manual D T...

Reviews: