  Mega TRIPAR Profile Plus                    Safety Precautions

Power Supply:

 The ADJ Mega TRIPAR Profile Plus contains a auto-

matic  voltage  switch,  which  will  auto  sense  the  voltage  when  it  is 

plugged into the power source. With this switch there is no need to 

worry  about  the  correct  power  voltage,  this  unit  can  be  plugged  in 

anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Mega TRIPAR Profile Plus can be controlled via DMX-512 protocol. 

The Mega TRIPAR Profile Plus has 5 DMX modes, please see pages 9-10 

for the different modes. The DMX address is set on the back panel of the 

Mega TRIPAR Profile Plus. Your unit and your DMX 

controller require a standard 3-pin XLR connec-

tor for data input and data output (Figure 1). We 

recommend Accu-Cable DMX cables. If you are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable (This cable may be 

purchased at almost all pro lighting stores). Your 

cables should be made with a male and female 

XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained and cannot be split.

ADJ Products, LLC  -  www.adj.com  - Mega TRIPAR Profile Plus User Manual Page 4

  Mega TRIPAR Profile Plus                               DMX Set Up

ADJ Products, LLC  -  www.adj.com  - Mega TRIPAR Profile Plus User Manual Page 5

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 26 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

Figure 1

Summary of Contents for MEGA TRIPAR PROFILE PLUS

Page 1: ...LC brands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property eq...

Page 2: ...ofile Plus Installation Mega TRIPAR Profile Plus Introduction Unpacking Thank you for purchasing the Mega TRIPAR Profile Plus by ADJ Products LLC Every Mega TRIPAR Profile Plus has been thoroughly tes...

Page 3: ...l pro lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split ADJ Products LLC...

Page 4: ...Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and errati...

Page 5: ...ducts LLC www adj com Mega TRIPAR Profile Plus User Manual Page 9 ADJ Products LLC www adj com Mega TRIPAR Profile Plus User Manual Page 8 Mega TRIPAR Profile Plus Operating Instructions UP button unt...

Page 6: ...is displayed Use the UP and DOWN buttons to scroll through the DMX states bLAC Blackout If the DMX signal is lost or interrupted the unit will automatically go into stand by mode LASt Last State If th...

Page 7: ...g his button will scroll through DMX address ing DMX Channel mode DMX last state setting and dimming curves Some fixtures will come with different DMX channel modes When your desired menu submenu is f...

Page 8: ...tton then using the or buttons to scroll through the DMX Channel Modes Set the mode before you address the fixture See the bottom of this page for the DMX modes 2 After you have selected your mode set...

Page 9: ...TROBING SLOW FAST 96 127 LED ON 128 159 STROBE PULSE SLOW FAST 160 191 LED ON 192 223 RANDOM STROBE SLOW FAST 224 255 LED ON 6 MASTER DIMMER 0 255 0 100 Mega TRIPAR Profile Plus 6 Channel Mode Mega TR...

Page 10: ...OLOR FADE 8 128 143 COLOR FADE 9 144 159 COLOR FADE 10 160 175 COLOR FADE 11 176 191 COLOR FADE 12 192 207 COLOR FADE 13 208 223 COLOR FADE 14 224 239 COLOR FADE 15 240 255 COLOR FADE 16 Mega TRIPAR P...

Page 11: ...CTIVE MODE 2 32 47 SOUND ACTIVE MODE 3 48 63 SOUND ACTIVE MODE 4 64 79 SOUND ACTIVE MODE 5 80 95 SOUND ACTIVE MODE 6 96 111 SOUND ACTIVE MODE 7 112 127 SOUND ACTIVE MODE 8 128 143 SOUND ACTIVE MODE 9...

Page 12: ...T SENSITIVE 10 DIMMER CURVES 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DEFAULT TO UNIT SETTING Mega TRIPAR Profile Plus 10 Channel Mode Channel Value Function 8 COL...

Page 13: ...77 74 Color44 173 176 147 164 212 0 Color12 45 48 255 71 77 71 Color45 177 180 88 2 163 0 Color13 49 52 255 83 134 83 Color46 181 184 0 38 86 0 Color14 53 56 255 93 182 93 Color47 185 188 0 142 208 0...