ADJ Products, LLC - www.adj.com - Mega GO Par64 PLUS User Manual Page 14
ADJ Products, LLC - www.adj.com - Mega GO Par64 PLUS User Manual Page 15
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-
Slave set-up. In a Master-Slave set-up one unit will act as the control-
ling unit and the others will react to the controlling units built-in pro-
grams. Any unit can act as a Master or as a Slave however, only one
unit can be programmed to act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of
the unit. Use standard XLR data cables to link your units together.
Remember that the Male XLR connector is the input and the Female
XLR connector is the ouput. The first unit in the chain (master) will use
the female XLR connector only. The last unit in the chain will use the
male XLR connector only.
2. Connect the first “Slave” unit to the “Master.”
3. Set the “Master” unit to your desired mode of operation. Set the
“Slave” unit(s) to the DMX address setting of 001.The “Slave”
unit(s) will now follow the “Master”.
Mega GO Par64 PLUS Master-Slave Configuration
Mega GO Par64 PLUS Operating Instructions
2. Press the SET UP button until “dr-X” is displayed. “X” represents
the displayed dimmer curve (0-4).
• 0 - Standard
• 1 - Stage
• 2 - TV
• 3 - Architectural
• 4 - Theatre
3. Press the UP or DOWN buttons to scroll through and select your
desired dimming curve.
Activate IR Sensor:
This function is used to activate and deactivate the IR sensor. When
this function is activated you can control the fixture using the ADJ
LED RC2, UC IR, or Airstream IR App. Please see the next pages
16-18 for controls and functions.
1. Plug the fixture in and press the MODE button until “dXX” is dis-
played. “XX” represents either “on” or “oFF”.
2. Press the SET UP button until “IrXX” is displayed. “XX” represents
either “on” or “oF”.
3. Press the UP or DOWN buttons to either activate the remote func-
tion (On) or deactivate it (Off).
Default Running Mode:
This is a default running mode. When this mode is activated all modes
will return to their default settings.
1. Plug the fixture in and press the MODE button until “dXX” is dis-
played. “XX” represents either “on” or “oFF”.
2. Press the SET UP button until “dEFA” is displayed.
3. Press the UP and DOWN buttons simultaneously. Press the
MODE button to exit.
247mm/9.72”
262.14mm/10.32”
210mm/8.26”
195.64mm/7.70”
111.74mm/4.39”
Mega GO Par64 PLUS CAD Drawing