I N S TA L L AT I O N

FLAMMABLE MATERIAL WARNING

Keep fixture minimum 8.5 in. (22cm) away from flammable materials and/or pyrotechnics.

ELECTRICAL CONNECTIONS

A qualified electrician should be used for all electrical connections and/or installations.

MINIMUM DISTANCE TO OBJECTS/SURFACES IS 1.6 FEET (0.5 METERS).

MINIMUM DISTANCE OF INFLAMMABLE MATERIALS FROM THE SURFACE IS 8.5 IN. 

(22 CM).

DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
•  Fixture MUST be installed following all local, national, and country commercial electrical and 

construction codes and regulations.

•  Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing 

the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine 

if the metal truss/structure or surface is properly certified to safely hold the combined weight of the 

fixture(s), clamps, cables, and accessories.

•  Maximum ambient operating temperature is 104°F (40°C).  Do  not  use  fixture  when  ambient 

temperature exceeds this value.

•  Fixture(s) should be installed outside walking paths, seating areas, or areas where unauthorized 

personnel might reach the fixture by hand.

•  NEVER stand directly below the fixture(s) when rigging, removingm, or servicing.

•  Overhead fixture installation must always be secured with a secondary safety attachment, such as 

an appropriately rated safety cable.

•  Allow approximately 15 minutes for the fixture to cool down before servicing.
IP RATING

This device is IP20 rated. This means that the unit is protected against the intrusion of 

solids 2.5mm in size or larger (approximately the size of an adult finger tip). The unit is NOT 

protected against water or liquid intrusion of any kind!
RIGGING

Overhead rigging requires extensive experience, including calculating working load limits, 

knowledge of installation material being used, and periodic safety inspection of all installation 

material and the fixture, among other skills. If you lack these qualifications, do not attempt the 

installation yourself. Improper installation can result in bodily injury.

Summary of Contents for Jolt Bar FX

Page 1: ...JOLT BAR FX User Manual ...

Page 2: ...arks or registered trademarks of their respective companies and are hereby acknowledged All non ADJ Products LLC brands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect econ...

Page 3: ...erview 8 Installation 9 Remove Device Management 12 Control Panel 13 System Menu 14 DMX Setup 17 DMX Traits 19 LED Pixel Zones 25 Color Macro Chart 26 Dimmer Modes and Curves 27 Daisy Chain Power Linking Cleaning and Maintenance 28 Dimensional Drawings 29 Specifications 30 FCC Statement 31 CONTEN T S ...

Page 4: ...ons Please do not return this device to your dealer without first contacting customer support Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Omega Brackets 1 83M locking power cable CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions ADJ SERVICE ...

Page 5: ... repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear identifying marks to that effect E ADJ Products LLC reserves...

Page 6: ...eturned to the shipper FEATURES The ADJ Jolt Bar FX is a professional linear LED fixture that delivers lighting designers huge output as well as the creative potential of brilliant bright white strobe blinder LEDs combined with multi colored chase effects in one versatile unit Ideal for concert productions festival stages and rental houses as well as for permanent installation in large nightclubs ...

Page 7: ...POSE FIXTURE TO RAIN AND MOISTURE MINIMUM DISTANCE TO OBJECTS SURFACES IS 1 6 FEET 0 5 METERS MINIMUM DISTANCE TO FLAMMABLE MATERIALS FROM THE SURFACE IS 8 5 INCHES 22 CM DO NOT TOUCH the fixture housing during operation Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before serving DO NOT shake fixture and avoid brute force when installing and or operating fixture D...

Page 8: ...EW Control Panel Firmware Upgrade Slot DMX Out Power Out DMX In Power In Power Out DMX Out Mounting Bracket Mounting Bracket Bracket Adjustment Knobs Bracket Adjustment Knobs Safety Cable Loop Safety Cable Loop ...

Page 9: ...erating temperature is 104 F 40 C Do not use fixture when ambient temperature exceeds this value Fixture s should be installed outside walking paths seating areas or areas where unauthorized personnel might reach the fixture by hand NEVER stand directly below the fixture s when rigging removingm or servicing Overhead fixture installation must always be secured with a secondary safety attachment such a...

Page 10: ...tures a mounting point on the yoke for the attachment of a mounting clamp There is also a safety cable loop located on the rear of the fixture see the illustration below When mounting the fixture to a truss or any other suspended or overhead installation be sure to secure appropriately rated clamps not included to the yoke and attach a separate SAFETY CABLE of the appropriate weight rating to the ...

Page 11: ...below for guidance 2 Remove the two 2 screws holding the connector plate in place as well as two 2 screws on the end of each adjacent unit for a total of six 6 screws Remove the connector plate 3 Place the connector plate across the gap between the two units making sure to align the plate with the four 4 screw holes Reinstall the four 4 screws that secure the connector plate in place as well as th...

Page 12: ...ible With RDM the DMX512 system becomes bi directional allowing a compatible RDM enabled con troller to send out a signal to devices on the wire as well as allowing the fixture to respond known as a GET command The controller can then use its SET command to modify settings that would typically have to be changed or viewed directly via the unit s display screen including the DMX Ad dress DMX Channe...

Page 13: ...currently displayed menu ENTER Select an option or confirm a selection This fixture includes a display lock feature which automatically shuts off the display screen after a certain period of inactivity This feature is OFF by default which means that the display will always remain on regardless of inactivity but can be configured to kick in after up to 10 minutes of inactivity See the System Menu s...

Page 14: ...h DMX Channel Mode 6CH 9CH 13CH 16CH 18CH 32CH 32ACh 38CH 43CH 64CH 78Ch 112CH 127CH No DMX Status Blackout Takes all traits to 0 when DMX signal is lost or interrupted Hold Holds all traits at last received value when DMX signal is lost or interrupted Manual Defaults to values set in Manual Mode when DMX signal is lost or interrupted CONTINUED ON NEXT PAGE SYSTEM MENU ...

Page 15: ...00 255 Red2 000 255 Green2 000 255 Blue2 000 255 White2 000 255 USB Port Power On Off Update Software Yes No Factory Restore Yes No MANUAL Red1 000 255 Note Manual control settings shall always hold when no DMX signal is detected Green1 000 255 Blue1 000 255 White1 000 255 Red2 000 255 Green2 000 255 Blue2 000 255 Note Manual control settings shall always hold when no DMX signal is detected White2...

Page 16: ...RE INFORMATION Fixture Use Hour LED Use Hour Total LED Hour LED On Hour LED Hours Reset Passcode 011 Temperature Fan State RDM UID xxxxxx Error Logs Fixture Errors Reset Error Log Passcode 011 No Yes Firmware Version x xx SYSTEM MENU ...

Page 17: ...fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Jolt Panel FX can be controlled via DMX 512 protocol and features multiple DMX channel modes Your unit and your DMX control ler require a 5 pin XLR connector for data input and data out...

Page 18: ...f this starting DMX address is achieved by setting the correct DMX address on the digital control display on the fixture You can set the same starting address for all fixtures or a group of fixtures or set different addresses for each individual fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way In this case please note that changing the settings ...

Page 19: ...ine 0 to 100 5 25 26 65 98 000 255 Outer Dimmer 0 to 100 6 26 27 66 99 000 255 Outer Dimmer Fine 0 to 100 7 8 Strobe Effect 000 002 Open 003 005 Strobe 006 050 Ramp up 051 100 Ramp down 101 150 Ramp up down 151 200 Lightning 201 255 Random 8 9 000 255 Strobe Rate slow to fast 9 10 000 255 Strobe Duration slow to fast 5 4 25 97 000 255 Outer Color Macros 7 27 28 67 100 Outer Strobe Effect 000 002 O...

Page 20: ...ro7 076 085 Macro8 086 095 Macro9 096 105 Macro10 106 115 Macro11 116 125 Macro12 126 135 Macro13 136 145 Macro14 146 155 Macro15 156 165 Macro16 166 175 Macro17 176 185 Macro18 186 195 Macro19 196 205 Macro20 206 215 Macro21 216 225 Macro22 226 235 Macro23 236 245 Macro24 246 255 Macro25 11 32 104 000 255 Outer Program Macro Speed 12 34 37 74 121 000 255 Inner Dimmer 0 to 100 13 35 38 75 122 000 ...

Page 21: ...Macro1 034 060 Macro2 061 088 Macro3 089 116 Macro4 117 144 Macro5 145 172 Macro6 173 200 Macro7 201 228 Macro8 229 255 Macro9 18 43 127 000 255 Inner Program Macro Speed 13 000 255 In Out Program Macro Speed slow to fast 1 1 1 1 1 1 1 1 1 000 255 Red 1 2 2 2 2 2 2 2 2 2 000 255 Green 1 3 3 3 3 3 3 3 3 3 000 255 Blue 1 4 4 4 4 4 4 4 4 4 000 255 Red 2 5 5 5 5 5 5 5 5 5 000 255 Green 2 6 6 6 6 6 6 6...

Page 22: ...2 22 22 000 255 Red 8 23 23 23 23 23 23 23 23 000 255 Green 8 24 24 24 24 24 24 24 24 000 255 Blue 8 25 25 25 25 000 255 Red 9 26 26 26 26 000 255 Green 9 27 27 27 27 000 255 Blue 9 28 28 28 28 000 255 Red 10 29 29 29 29 000 255 Green 10 30 30 30 30 000 255 Blue 10 31 31 31 31 000 255 Red 11 32 32 32 32 000 255 Green 11 33 33 33 33 000 255 Blue 11 34 34 34 34 000 255 Red 12 35 35 35 35 000 255 Gre...

Page 23: ...00 255 Green 19 57 57 000 255 Blue 19 58 58 000 255 Red 20 59 59 000 255 Green 20 60 60 000 255 Blue 20 61 61 000 255 Red 21 62 62 000 255 Green 21 63 63 000 255 Blue 21 64 64 000 255 Red 22 65 65 000 255 Green 22 66 66 000 255 Blue 22 67 67 000 255 Red 23 68 68 000 255 Green 23 69 69 000 255 Blue 23 70 70 000 255 Red 24 71 71 000 255 Green 24 72 72 000 255 Blue 24 73 73 000 255 Red 25 74 74 000 2...

Page 24: ...4 94 000 255 Red 32 95 95 000 255 Green 32 96 96 000 255 Blue 32 13 25 25 49 49 97 105 000 255 White 1 14 26 26 50 50 98 106 000 255 White 2 15 27 27 51 51 99 107 000 255 White 3 16 28 28 52 52 100 108 000 255 White 4 29 29 53 53 101 109 000 255 White 5 30 30 54 54 102 110 000 255 White 6 31 31 55 55 103 111 000 255 White 7 32 32 56 56 104 112 000 255 White 8 57 57 105 113 000 255 White 9 58 58 10...

Page 25: ...ite2 White4 White3 White7 White8 White6 White5 RGB1 RGB2 RGB3 RGB4 RGB5 RGB6 RGB7 RGB8 RGB1 RGB2 RGB3 RGB4 RGB5 RGB6 RGB7 RGB8 White1 White2 White4 White3 White7 White8 White6 White5 32 CHANNEL MODE RGB1 RGB2 RGB3 RGB4 RGB5 RGB6 RGB7 RGB8 RGB9 RGB10 RGB11 RGB12 RGB13 RGB14 RGB15 RGB16 White1 White2 White3 White4 White5 White6 White9 White10 White7 White8 White11 White12 White13 White14 White15 Whi...

Page 26: ...92 099 0 255 50 Color13 100 106 0 255 100 Color14 107 113 0 255 150 Color15 114 121 0 255 200 Color16 122 128 0 255 255 Color17 129 136 0 200 255 Color18 137 143 0 150 255 Color19 144 151 0 100 255 Color20 152 158 0 50 255 Color21 159 165 0 0 255 Color22 166 173 50 0 255 Color23 174 180 100 0 255 Color24 181 188 150 0 255 Color25 189 195 200 0 255 Color26 196 203 255 0 255 Color27 204 210 255 0 20...

Page 27: ...27 DIMMER MO DES AND C U RVES ...

Page 28: ...ts or ammonia based cleaners MAINTENANCE Regular inspections are recommended to ensure proper function and extended life There are no user serviceable parts inside this fixture Please refer all other service issues to an authorized ADJ service technician Should you need any spare parts please order genuine parts from your local ADJ dealer Please refer to the following points during routine inspect...

Page 29: ...29 DIMENSIO NS Dimensions are not drawn to scale ...

Page 30: ...2 Dim Curves 4 Presets Linear Square Inverse Square and S Curve 0 100 Smooth Dimming Strobe shutter pulse control Max Strobe Rate 25Hz Min Strobe Rate 0 35Hz With Wired Digital Communication Network Display OLED display with 4 button touch menu CONNECTIONS Data 5 pin DMX In Out 180 degree mounting bracket system Power locking power in out Connect fixtures seamlessly using included metal bracket at...

Page 31: ... energy and if not installed and used in accordance with the included instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can be determined by turning the device off and on the user is encouraged to try to ...

Page 32: ......