background image

ADJ Products, LLC  -  www.adj.com  - Focus Spot Three Z Instruction Manual Page 9

ADJ Products, LLC  -  www.adj.com  - Focus Spot Three Z Instruction Manual Page 8

Power Supply:

 The ADJ Focus Spot Three Z contains a automatic 

voltage switch, which will auto sense the voltage when it is plugged 

into the power source. With this switch there is no need to worry about 

the correct power voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of different manufactures to be linked together and operate from a 

single  controller,  as  long  as  all  fixtures and  the  controller  are DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The  Focus  Spot  Three  Z  can  be  controlled  via  DMX-

512 protocol. The Focus Spot Three Z has 2 DMX channel modes; 

18 channel mode & 21 channel mode. The DMX 

address is set electronically using the controls on 

the front panel of the unit. Your unit and your DMX 

controller require a approved DMX-512 110 Ohm 

Data cable for data input and data output (Figure 

1). We recommend Accu-Cable DMX cables. If you 

are making your own cables, be sure to use stan-

dard 110-120 Ohm shielded cable (This cable may 

be purchased at almost all professional sound and 

 Focus Spot Three Z 

                                  DMX Set Up

Figure 1

 Focus Spot Three Z  

                                 Base Layout 

1. LED:   

DMX 

On 

DMX input present 

MASTER 

On 

Master Mode 

SLAVE 

ON 

Slave Mode 

SOUND 

Flashing 

Sound activation 

2. Display: To show the various menus and the selected function; 

3. Button:   

MENU 

To select the programming  functions 

  UP   

To go forward in the selected functions   

  DOWN 

To go backward in the selected functions 

ENTER 

To confirm the selected functions 

4. IR receiver: To receive the IR signal; 

5. Fuse (T5Amp):  Protects the unit from over‐voltage or short circuit; 

6. Power In/out:  

 

 power cable  connectors for power input/output;

7. DMX In/Out:    3‐pin XLR connectors for DMX 512 operation. 

Summary of Contents for Focus Spot Three Z

Page 1: ...t names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and...

Page 2: ...nstructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Focus Spot Three Z General Instructions Focus...

Page 3: ...s fixture should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified servi...

Page 4: ...afety holes located on the bottom base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw NOTICE The suitable enviromental temperature for...

Page 5: ...ere in a DMX line at the beginning at the end or anywhere in the middle Therefore the first fixture controlled by the controller could be the last fixture in the chain When a fixture is assigned a DMX...

Page 6: ...cuit and erratic behavior DMX512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT DMX512 DMX DMX C...

Page 7: ...E 100 108 GOBO 5 SHAKE 109 117 GOBO 6 SHAKE 118 127 GOBO 7 SHAKE 128 189 COUNTER CLOCKWISE ROTATION FAST SLOW 190 193 STOP 194 255 CLOCKWISE ROTATION SLOW FAST Focus Spot Three Z 18 Channel Mode Chann...

Page 8: ...5 0 255 SHOW SPEED FAST SLOW 16 DIMMER MODES 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DEFAULT TO UNIT 17 0 255 PAN TILT SPEED FAST SLOW Focus Spot Three Z 18 Chann...

Page 9: ...SHAKE 91 99 GOBO 4 SHAKE 100 108 GOBO 5 SHAKE 109 117 GOBO 6 SHAKE 118 127 GOBO 7 SHAKE 128 189 COUNTER CLOCKWISE FAST SLOW 190 193 STOP 194 255 CLOCKWISE ROTATION SLOW FAST Focus Spot Three Z 21 Chan...

Page 10: ...H SOUND ACTIVITY 18 0 255 SHOW SPEED FAST SLOW 19 DIMMER MODES 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DEFAULT TO UNIT 20 0 255 PAN TILT SPEED FAST SLOW Focus Spo...

Page 11: ...played X represents the displayed address Press the UP or DOWN buttons to find your desired address 3 Press ENTER to confirm and then press and hold the MENU button for at least three seconds to assig...

Page 12: ...owest and 100 most sensitive 3 Press ENTER to set you desired level DMX Last State This mode can be used as a precau tion mode that in case the DMX signal is lost the operating mode chosen in the setu...

Page 13: ...the MENU button until Manual Test is displayed press ENTER 2 Use the UP or DOWN buttons to find the functions that you wish to test 3 Once you find a function you wish to test press the ENTER button...

Page 14: ...fixture will now be displayed Press MENU to exit Firmware Version This will display the firmware soft ware version 1 Press the MENU button until Firmware Version is displayed Press the ENTER button an...

Page 15: ...ustment for the 1st gobo wheel 1 Press the ENTER button for at least 5 seconds then press the UP or DOWN buttons so that Gobo 1 Offset is displayed press ENTER 2 Use the UP and DOWN buttons to make yo...

Page 16: ...ity level Show Mode This mode allows either a single unit or several units linked together to run one of four shows that you choose 1 Press the MENU button until Show Mode is displayed and press ENTER...

Page 17: ...tivate the sound active mode SHOW This activates the show mode Use buttons 1 4 to select your desired show Focus Spot Three Z Remote Operation Focus Spot Three Z Master Slave Set Up Master Slave Opera...

Page 18: ...obos 1 To change a gobo look inside the unit from the front lens and notice the prisms Rotate the moving head so that prisms are facing down The top shell facing you is the shell you need to remove 2...

Page 19: ...ation to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired...

Page 20: ...Duty Cycle None DMX 2 DMX Channel Modes 18 Channel Mode 21 Channel Mode Sound Active Yes Working Position Any Safe Secure Position Warranty 2 Year 730 days Auto Sensing Voltage This fixture contains...

Reviews: