background image

19

Color

DMX Value

COLOR INTENSITY

Color

DMX Value

COLOR INTENSITY

WW

CW

A

WW

CW

A

Color 1(off)

0

0

0

0

Color 18

128-135

1

134

201

Color 2

1-7

255

206

143

Color 19

136-143

0

145

212

Color 3

8-15

254

177

153

Color 20

144-151

0

121

192

Color 4

16-23

254

192

138

Color 21

152-159

0

129

184

Color 5

24-31

254

165

98

Color 22

160-167

0

83

115

Color 6

32-39

254

121

0

Color 23

168-175

0

97

166

Color 7

40-47

176

17

0

Color 24

176-183

1

100

167

Color 8

48-55

96

0

11

Color 25

184-191

0

40

86

Color 9

56-63

234

139

171

Color 26

192-199

209

219

182

Color 10

64-71

254

5

97

Color 27

200-207

42

165

85

Color 11

72-79

175

77

173

Color 28

208-215

0

46

35

Color 12

80-87

119

130

199

Color 29

216-223

8

107

222

Color 13

88-95

147

164

212

Color 30

224-231

107

156

231

Color 14

96-103

88

2

163

Color 31

232-239

65

198

247

Color 15

104-111

0

38

86

Color 32

240-247

0

0

189

Color 16

112-119

0

142

208

Color 33

248-255

165

35

1

Color 17

120-127

52

148

209

C O L O R   M A C R O   C H A R T

Summary of Contents for FLA120

Page 1: ...FLAT PAR TW12 User Guide...

Page 2: ...and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the impr...

Page 3: ...nance Guidelines Maintenance Cleaning Fuse Replacement Troubleshooting 8 Fixture Overview 9 Installation Instructions 10 DMX Setup 11 System Menu 12 ADJ LED RC3 Infrared Remote 16 Photometric Chart Di...

Page 4: ...card the outer shipping carton in the trash Please recycle whenever possible CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with quest...

Page 5: ...pair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof includin...

Page 6: ...mage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF AS DOING SO WILL VOID YOUR MAN...

Page 7: ...This unit is intended for indoor use only Use of this product outdoors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in a safe and stable...

Page 8: ...optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry...

Page 9: ...9 OVERVIEW Fuse 1A 250V 3 Pin DMX Out Mounting Bracket Stand Power Cable In Gel Holder Power Cable Out 3 Pin DMX In Mounting Bracket Stand Positional Knob TOP VIEW BOTTOM VIEW...

Page 10: ...ience including calculating working load limits installation material being used and periodic safety inspection of all installation material and the fixture among other skills If you lack these qualif...

Page 11: ...a Cable DMX Cable Requirements For DMX Operation The FLAT PAR TW12 can be controlled via DMX 512 protocol Your unit and your DMX controller requires a 5 pin XLR connector for data input output We reco...

Page 12: ...onds to unlock LED Display On Off To set the display press the MODE button until dXX is displayed XX represents either on or oFF Use the UP or DOWN buttons to select either don LED display on at all t...

Page 13: ...utton 4 S XXX will be displayed indicating that the device is in strobing mode The strobing can be adjusted between S 000 strobe off to S 015 fastest strobe Sound Active Mode In this mode the Flat Par...

Page 14: ...or oF 3 Press the UP or DOWN buttons to either activate the remote function On or deactivate it Off DMX State This setting defines the behavior of the fixture in the event that the DMX signal is lost...

Page 15: ...chain your units via the XLR connectors on the rear of the units Remember the Male XLR connector is the input and the Female XLR connector is the output The first unit in the chain primary will use t...

Page 16: ...just the DMX address In dimmer curve mode press the the and buttons to scroll through the dimmer curves See the System Menu section of this manual for detailed information In DMX Channel selection pre...

Page 17: ...17 DIMMING C U RVE PHOTOM E T RIC C H ART...

Page 18: ...Color Fade 6 176 183 Color Fade 7 184 191 Color Fade 8 192 199 Color Change 1 200 207 Color Change 2 208 215 Color Change 3 216 223 Color Change 4 224 231 Color Change 5 232 239 Color Change 6 240 247...

Page 19: ...0 97 166 Color 7 40 47 176 17 0 Color 24 176 183 1 100 167 Color 8 48 55 96 0 11 Color 25 184 191 0 40 86 Color 9 56 63 234 139 171 Color 26 192 199 209 219 182 Color 10 64 71 254 5 97 Color 27 200 2...

Page 20: ...ately Dual yoke allows fixture to be hung or set on the ground Data linkable via 3 pin XLR cables With Wired Digital Communication Network Power Draw 61W total All LED s Full On Color Temperature 6500...

Page 21: ...21 DIMENSIO N D RAW ING S Dimensions not to scale...

Page 22: ...ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television recept...

Page 23: ......

Reviews: