1. Open the shipping carton and carefully remove the device from the shipping carton. 

2. Be sure to remove ALL the packing material, paying particular attention to the area around the fog   

    outlet vent. 

3. Set the device on a flat dry surface. Open the icebox by unscrewing the knob located at the 

   top front of the unit. Once the box is opened, fill the box with ice. The lid should close quickly and 

   securely. Do not overfill the box.

4. After filling the icebox, unscrew and remove the tank reservoir cap. 

5. Fill the reservoir with ADJ brand fog juice only, and replace the reservoir cap. Never run the 

    device on anything other than an approved, ADJ branded water-based fog juice, as doing so can 

    result in severe damage to your device. 

6. Connect one end of the drainage tube to the drainage spout on the rear of the unit. Insert the 

    other end of the drainage tube into the drainage bag. When the ice melts, the water will empty 

    into the drainage bag. 

7. Remove the timer remote control and firmly attach the remote control to the remote control jack 

    located on the rear unit. Follow the operating instructions in the Wired Timer Remote Control 

    section of this manual. 

8. Plug the device into a matching power supply and flip the power switch to the ON position. 

9. After power is applied, the device will begin to warm up. The device should be fully warmed up 

    after 180 seconds. “Ready To Fog” will be displayed on the screen once the device is warmed up 

    and ready to emit a fog. Additionally, if the Tank Lamp has been turned on, it will indicate device 

    status by changing colors: red when the device is warming up, and green when ready for use. See 

    the System Menu section for details on how to operate the tank lamp. 

NOTE: When more than one means of control is connected to the device, the following command 

priority applies: 

- First Priority: DMX Signal

- Second Priority: Wired Timer Remote Control 

- Third Priority: Control Panel 

DMX SIGNAL TAKES PRIORITY OVER ALL OTHER MEANS OF DEVICE CONTROL.

Summary of Contents for ENTOUR CHILL

Page 1: ...User Manual ENTOUR CHILL US SKU ENT791 UPC 818651028249 ITF 14 10818651028246...

Page 2: ...quipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a...

Page 3: ...Features I Warranty Registration Installation Safety Guidelines Overview General Set Up System Menu DMX Traits Wired Timer Remote Control Dimensional Drawings Fluid Sensor Maintenance Storage Breaker...

Page 4: ...adj com ADJ SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 60 Fax 31 45 546 85 96 support adj eu ADJ PRODUCTS LLC USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 2650 Fax 323 5...

Page 5: ...ckage A brief description of the problem and R A number must also be writ ten down on a paper included in the shipping carton If the unit is under warranty you must provide a copy of your proof of pur...

Page 6: ...se this device to rain or moisture Do not attempt to operate this device if the power cord has been frayed or broken Do not try to remove or break off the ground prong from the electrical cord This pr...

Page 7: ...age 7 Entour Chill Overview 1 Carrying Handle 2 Fluid Tank 3 Ice Box 4 Smoke Outlet 5 LCD Display 6 LCD Screen Buttons 7 DMX Input 8 DMX Output 9 Remote Control Jack 10 Power Switch 11 No Fuse Breaker...

Page 8: ...drainage tube into the drainage bag When the ice melts the water will empty into the drainage bag 7 Remove the timer remote control and firmly attach the remote control to the remote control jack loca...

Page 9: ...below During regular operation pressing the MENU button once will access the fixture s main menu Continue to press the MENU button to cycle through the vari ous menu options When you reach a field th...

Page 10: ...Duration Setting This setting allows the user to adjust the length of time during which the device emits fog DMX512 ADD In this submenu you can adjust the DMX address of the device QUICK START In thi...

Page 11: ...ll DMX Channel Values Functions Supports Software Versions 1 0 and up Features subject to change without notice Channel DMX Value Function 1 000 031 Smoke Off 032 255 Smoke On ADJ Products LLC www adj...

Page 12: ...stops when this button is released 4 Duration Control Knob This knob will adjust the duration time of fog output 5 Interval Control Knob This knob will adjust the interval time between fog output Ent...

Page 13: ...ADJ Products LLC www adj com Entour Chill User Manual Page 13 Entour Chill Dimensional Drawings...

Page 14: ...o preserve the machine life and its internal parts When the fluid sensor determines that the fluid tank is empty the device will automatically stop work ing Entour Chill Storage Drain all liquid and r...

Page 15: ...o continue pushing the manual fog button as this may damage the machine Check the fluid level and the breaker and be sure the wall outlet is sending power If all these appear to be operational and the...

Page 16: ...repair labor because of defects in ma terial or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the re pair of the product or replacement thereof includ...

Page 17: ...controls timer output continuous output 3 pin DMX In Out connections Locking power connection Includes ADJ s FFFTR MK II wired timer remote control Features Timer On Off Continuous and manual fog plug...

Page 18: ......

Reviews: