background image

ADJ Products, LLC  -  www.adj.com  - Entour Chill User Manual Page 14

  

Entour Chill

                                                                                               

Maintenance 

Before performing maintenance, please ensure that the power is “Off” and the power cord is 

disconnected from the power source. Always make sure the machine has cooled down. 

DO NOT let the fog fluid get dirty. 

Always keep the air inlet clean and clear of any objects or dust, making sure to clean the air inlet 

after prolonged periods of use.

Before storing the machine, please drain all liquid from the fluid tank. Disconnect and empty the 

drainage bag. Follow the instructions detailed in the Storage section of this manual.

  

Entour Chill

                                                                         

                  Fluid Sensor 

The fluid sensor is a safe-guard feature designed to preserve the machine life and its internal parts. 

When the fluid sensor determines that the fluid tank is empty, the device will automatically stop work-

ing. 

  

Entour Chill

                                                                                                         

Storage 

Drain all liquid and remove all ice from the ice box before storing for a long time. Store the device in 

a cool area and cover the device to prevent excessive accumulation of dust. Do not leave the device 

out in the sun for long periods.When storing the unit for long periods, it is advised to run the unit at 

least once every 3-4 months, as long periods of inactivity can shorten your machine’s life. Only run 

ADJ-branded water-based fog juice through your unit. Running anything other then water based fog 

juice will result in severe damage to your device.

Avoid placing heavy objects on top of the device. Placing heavy objects on top of the device could 

damage the reservoir tank and ice box/ice box lid.

Summary of Contents for ENTOUR CHILL

Page 1: ...User Manual ENTOUR CHILL US SKU ENT791 UPC 818651028249 ITF 14 10818651028246...

Page 2: ...quipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a...

Page 3: ...Features I Warranty Registration Installation Safety Guidelines Overview General Set Up System Menu DMX Traits Wired Timer Remote Control Dimensional Drawings Fluid Sensor Maintenance Storage Breaker...

Page 4: ...adj com ADJ SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 60 Fax 31 45 546 85 96 support adj eu ADJ PRODUCTS LLC USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 2650 Fax 323 5...

Page 5: ...ckage A brief description of the problem and R A number must also be writ ten down on a paper included in the shipping carton If the unit is under warranty you must provide a copy of your proof of pur...

Page 6: ...se this device to rain or moisture Do not attempt to operate this device if the power cord has been frayed or broken Do not try to remove or break off the ground prong from the electrical cord This pr...

Page 7: ...age 7 Entour Chill Overview 1 Carrying Handle 2 Fluid Tank 3 Ice Box 4 Smoke Outlet 5 LCD Display 6 LCD Screen Buttons 7 DMX Input 8 DMX Output 9 Remote Control Jack 10 Power Switch 11 No Fuse Breaker...

Page 8: ...drainage tube into the drainage bag When the ice melts the water will empty into the drainage bag 7 Remove the timer remote control and firmly attach the remote control to the remote control jack loca...

Page 9: ...below During regular operation pressing the MENU button once will access the fixture s main menu Continue to press the MENU button to cycle through the vari ous menu options When you reach a field th...

Page 10: ...Duration Setting This setting allows the user to adjust the length of time during which the device emits fog DMX512 ADD In this submenu you can adjust the DMX address of the device QUICK START In thi...

Page 11: ...ll DMX Channel Values Functions Supports Software Versions 1 0 and up Features subject to change without notice Channel DMX Value Function 1 000 031 Smoke Off 032 255 Smoke On ADJ Products LLC www adj...

Page 12: ...stops when this button is released 4 Duration Control Knob This knob will adjust the duration time of fog output 5 Interval Control Knob This knob will adjust the interval time between fog output Ent...

Page 13: ...ADJ Products LLC www adj com Entour Chill User Manual Page 13 Entour Chill Dimensional Drawings...

Page 14: ...o preserve the machine life and its internal parts When the fluid sensor determines that the fluid tank is empty the device will automatically stop work ing Entour Chill Storage Drain all liquid and r...

Page 15: ...o continue pushing the manual fog button as this may damage the machine Check the fluid level and the breaker and be sure the wall outlet is sending power If all these appear to be operational and the...

Page 16: ...repair labor because of defects in ma terial or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the re pair of the product or replacement thereof includ...

Page 17: ...controls timer output continuous output 3 pin DMX In Out connections Locking power connection Includes ADJ s FFFTR MK II wired timer remote control Features Timer On Off Continuous and manual fog plug...

Page 18: ......

Reviews: