ADJ ENCORE BURST RGBW IP User Instructions Download Page 6

ADJ Products, LLC  -  www.adj.com  - Encore Burst RGBW IP User Manual Page 5

  

Encore Burst RGBW IP

                                                            

Safety Precautions

FOR YOUR OWN PERSONAL SAFETY, PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY 

BEFORE YOU ATTEMPT TO INSTALL OR OPERATE THIS UNIT!

 •  THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS    

   YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM   

   MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND 

   GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO  

   ANY WARRANTY CLAIMS AND/OR REPAIRS.
 •  DO NOT PLUG THE FIXTURE INTO A DIMMER PACK!

   NEVER OPEN THIS FIXTURE WHILE IN USE!

   UNPLUG POWER BEFORE SERVICING FIXTURE!

   NEVER TOUCH THE FIXTURE DURING OPERATION AS IT MAY BE HOT!

   KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
 •  ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE    

   (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION AND/OR 

   ELECTRICAL SHORT CIRCUIT.
 •  IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH AS RELOCATION   

   FROM  AN  OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, DO NOT POWER THE FIXTURE 

   ON  IMMEDIATELY.  INTERNAL CONDENSATION AS A RESULT OF ENVIROMENTAL TEMPERATURE 

   CHANGE CAN CAUSE INTERNAL FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS    

   REACHED ROOM TEMPERATURE BEFORE POWERING ON.
 •  NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS!    

   SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
 •  Be sure that the local power outlet is compatible with the required voltage for your unit.
 •  Do not attempt to operate this unit if the power cord has been frayed or broken. 
 •  Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to  

 

   reduce the risk of electrical shock and fire in case of an internal short.
 •  Disconnect from main power before making any type of connection.
 •  Do not remove the cover under any conditions. There are no user serviceable parts inside.
 •  Never operate this unit when it’s cover is removed.
 •  Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this  

   device and a wall.
 •  Do not attempt to operate this unit, if it becomes damaged.
 •  Always mount this unit in safe and stable matter.
 •  Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed   

   upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point    

   where they exit from the appliance. 
 • Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 20 for cleaning    

   details.
 •  Heat -This fixture should be situated away from heat sources such as radiators, heat registers, stoves, or other  

 

   appliances (including amplifiers) that produce heat.
 •  The fixture should be serviced by qualified service personnel when the appliance does not appear to operate  

   normally or exhibits a marked change in performance.

Summary of Contents for ENCORE BURST RGBW IP

Page 1: ...User Instructions ENCORE BURST RGBW IP...

Page 2: ...art 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interfer...

Page 3: ...eatures I Warranty Registration Safety Guidelines IP65 Notice Overview Installation Connections DMX Set Up DMX Addressing DMX Modes System Menu Multiple Unit Power Linking I Dimmer Curve Chart Dimensi...

Page 4: ...s contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Customer Support Contact ADJ Service for any product re...

Page 5: ...items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief descri...

Page 6: ...NTO THE LIGHT SOURCE RETINA INJURY RISK MAY INDUCE BLINDNESS SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK Be sure that the local power outlet is compatible with the required voltage for your unit D...

Page 7: ...tion against particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has...

Page 8: ...com Encore Burst RGBW IP User Manual Page 7 Encore Burst RGBW IP Overview LCD Screen Mode Button Up Button Down Button Enter Button Safety Cable Rigging Point IP65 5 Pin DMX Out IP65 5 Pin DMX In IP65...

Page 9: ...ropriately reated professional grade rigging clamp not included to the included Omega Bracket using an M12 screw and nut not included With the rigging clamp securely attached to the Omega Bracket atta...

Page 10: ...END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE AVAILABLE AT MOST ELECTRICAL SUPPLIERS TO PREVENT WATER CORROSION AND OR ELECTRICAL SHORT CIRCUIT TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WA...

Page 11: ...TA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Encore Burst RGBW IP can be controlled via DMX 512 protocol...

Page 12: ...ch individual fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures sim...

Page 13: ...alf CT Blue Steel Blue Lighter Blue Light Blue Medium Blue Green Dark Green Primary Green Moss Green Fern Green JAS Green Lime Green Spring Yellow Deep Amber Chrome Orange Orange Gold Amber Millennium...

Page 14: ...2Sec 0 3Sec 0 4Sec 0 5Sec 0 6Sec 0 7Sec 0 8Sec 0 9Sec 1 0Sec 1 5Sec 2 0Sec 3 0Sec 4 0Sec 5 0Sec 6 0Sec 7 0Sec 8 0Sec 9 0Sec 10Sec Default to Unit Setting 000 020 021 040 041 060 061 080 081 100 101 1...

Page 15: ...Setting 900HZ 1000HZ 1100HZ 1200HZ 1300HZ 1400HZ 1500HZ 2500HZ 4000HZ 5000HZ 6000HZ 10000HZ 15000HZ 20000HZ 25000HZ GAMMA Default to Unit Setting 1 0 2 0 2 2 2 4 2 6 2 8 No Function 11 000 015 016 030...

Page 16: ...in menu Once in the main menu you can navigate through the different menu s with the UP DOWN and MENU buttons When you reach a field that requires adjusting press the ENTER button to access that field...

Page 17: ...l Running Time Not Resettable Total Running Time Resettable Reset Total Running Time Current Software Version Current DMX Values Current Temperature Total LED On Running Time Not Resettable LED On Run...

Page 18: ...D REFRESH RATE In this menu you are able to select your desired LED refresh rate GAMMA In this menu you are able to select your desired gamma setting DISPLAY In this menu you you are able to activate...

Page 19: ...URE TEMPS Current The current unit temperature is displayed Max Resettable Maximum temperature that has been recorded before reset and after reset This temperature may not be the same as the temperatu...

Page 20: ...ER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE CHECK SILK SCREEN FOR MAX AMPS Encore Burst RGBW IP Dimmer Curve Chart DIMMER 100 50 10 0 Time ms 0 Sec 255 255 0...

Page 21: ...cables are connected to the right connectors it does matter which way the inputs and outputs are connected Due to fog residue smoke and dust cleaning the internal and external optical lenses must be c...

Page 22: ...and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to...

Page 23: ...working position Power Draw 121W Weight 8 lbs 3 6 Kgs Dimensions 9 21 L x 9 8 W x 12 12 H 234 x 249 x 308mm DMX Channels 5 DMX Modes 4 6 7 8 11 Warranty 2 Year 730 days Please Note Specifications and...

Reviews: