DMX Set Up

DMX-512:

 DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication 

between  intelligent  fixtures  and  controllers.  A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the 

DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a 

DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of different manufactures to be 

linked together and operate from a single controller, as long as all fixtures and the controller are DMX 

compliant.  To ensure proper DMX data transmission, when using several DMX fixtures try to use 

the shortest cable path possible. The order in which fixtures are connected in a DMX line does not 

influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed 

anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is 

assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that 

unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 The Encore Burst RGBW IP can be controlled 

via DMX-512 protocol. The Encore Burst RGBW IP has multiple DMX channel modes. Your unit and 

your DMX controller requires a 5-pin XLR connector for data input and data output. We recommend Accu-

Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded 

cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with 

a male and female XLR connector on either end of the cable. Also remember that DMX cable must be 

daisy chained and cannot be split.

Special Note: Line Termination.

 When longer runs of cable are used, you may need to use a terminator 

on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected 

between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female 

XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ 

part number Z-DMX/T) will decrease the possibilities of erratic behavior. 

TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIXTURE, 

ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED AND ONLY IP65 RATED POWER 

AND DATE CABLES MUST BE USED.

Summary of Contents for ENCORE BURST RGBW IP

Page 1: ...User Instructions ENCORE BURST RGBW IP...

Page 2: ...art 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interfer...

Page 3: ...eatures I Warranty Registration Safety Guidelines IP65 Notice Overview Installation Connections DMX Set Up DMX Addressing DMX Modes System Menu Multiple Unit Power Linking I Dimmer Curve Chart Dimensi...

Page 4: ...s contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Customer Support Contact ADJ Service for any product re...

Page 5: ...items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief descri...

Page 6: ...NTO THE LIGHT SOURCE RETINA INJURY RISK MAY INDUCE BLINDNESS SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK Be sure that the local power outlet is compatible with the required voltage for your unit D...

Page 7: ...tion against particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has...

Page 8: ...com Encore Burst RGBW IP User Manual Page 7 Encore Burst RGBW IP Overview LCD Screen Mode Button Up Button Down Button Enter Button Safety Cable Rigging Point IP65 5 Pin DMX Out IP65 5 Pin DMX In IP65...

Page 9: ...ropriately reated professional grade rigging clamp not included to the included Omega Bracket using an M12 screw and nut not included With the rigging clamp securely attached to the Omega Bracket atta...

Page 10: ...END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC GREASE AVAILABLE AT MOST ELECTRICAL SUPPLIERS TO PREVENT WATER CORROSION AND OR ELECTRICAL SHORT CIRCUIT TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WA...

Page 11: ...TA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Encore Burst RGBW IP can be controlled via DMX 512 protocol...

Page 12: ...ch individual fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures sim...

Page 13: ...alf CT Blue Steel Blue Lighter Blue Light Blue Medium Blue Green Dark Green Primary Green Moss Green Fern Green JAS Green Lime Green Spring Yellow Deep Amber Chrome Orange Orange Gold Amber Millennium...

Page 14: ...2Sec 0 3Sec 0 4Sec 0 5Sec 0 6Sec 0 7Sec 0 8Sec 0 9Sec 1 0Sec 1 5Sec 2 0Sec 3 0Sec 4 0Sec 5 0Sec 6 0Sec 7 0Sec 8 0Sec 9 0Sec 10Sec Default to Unit Setting 000 020 021 040 041 060 061 080 081 100 101 1...

Page 15: ...Setting 900HZ 1000HZ 1100HZ 1200HZ 1300HZ 1400HZ 1500HZ 2500HZ 4000HZ 5000HZ 6000HZ 10000HZ 15000HZ 20000HZ 25000HZ GAMMA Default to Unit Setting 1 0 2 0 2 2 2 4 2 6 2 8 No Function 11 000 015 016 030...

Page 16: ...in menu Once in the main menu you can navigate through the different menu s with the UP DOWN and MENU buttons When you reach a field that requires adjusting press the ENTER button to access that field...

Page 17: ...l Running Time Not Resettable Total Running Time Resettable Reset Total Running Time Current Software Version Current DMX Values Current Temperature Total LED On Running Time Not Resettable LED On Run...

Page 18: ...D REFRESH RATE In this menu you are able to select your desired LED refresh rate GAMMA In this menu you are able to select your desired gamma setting DISPLAY In this menu you you are able to activate...

Page 19: ...URE TEMPS Current The current unit temperature is displayed Max Resettable Maximum temperature that has been recorded before reset and after reset This temperature may not be the same as the temperatu...

Page 20: ...ER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE CHECK SILK SCREEN FOR MAX AMPS Encore Burst RGBW IP Dimmer Curve Chart DIMMER 100 50 10 0 Time ms 0 Sec 255 255 0...

Page 21: ...cables are connected to the right connectors it does matter which way the inputs and outputs are connected Due to fog residue smoke and dust cleaning the internal and external optical lenses must be c...

Page 22: ...and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to...

Page 23: ...working position Power Draw 121W Weight 8 lbs 3 6 Kgs Dimensions 9 21 L x 9 8 W x 12 12 H 234 x 249 x 308mm DMX Channels 5 DMX Modes 4 6 7 8 11 Warranty 2 Year 730 days Please Note Specifications and...

Reviews: