ADJ DOTZ TPAR User Instructions Download Page 3

Power Supply:

 The ADJ Dotz TPar System contains a automatic volt-

age switch, which will auto sense the voltage when it is plugged into 

a power source. With this switch there is no need to worry about the 

correct power voltage, this unit can be plugged in anywhere. Always 

use the PowerCon cord that came with the unit.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The  Dotz  TPar  System  can  be  controlled  via  DMX-512  protocol.  The 

Dotz TPar System has 5 DMX Channel Modes. The DMX address is set 

on the rear panel of the Dotz TPar System. Your unit and your DMX con-

troller require a approved DMX-512 110 Ohm Data cable for data input 

and data output (Figure 1). We recommend Accu-

Cable DMX cables. If you are making your own 

cables,  be  sure  to  use  standard  110-120  Ohm 

shielded  cable  (This  cable  may  be  purchased 

at  almost  all  professional  sound  and  lighting 

stores). Your cables should be made with a male 

and female XLR connector on either end of the 

cable. Also remember that DMX cable must be 

daisy chained and cannot be split.

ADJ Products, LLC  -  www.adj.com  - Dotz TPar System User Manual Page 5

  Dotz TPar System                                                    Set Up

Figure 1

  Dotz TPar System                                Safety Precautions

ADJ Products, LLC  -  www.adj.com  - Dotz TPar System User Manual Page 4

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids  into or on to your unit.

•   Be sure that the local power outlet match that of the required volt- 

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 23 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

Summary of Contents for DOTZ TPAR

Page 1: ...C brands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indi rect economic loss associated with the use or reliance of any information contained within this document and or as a r...

Page 2: ...ion Carefully check the shipping carton for damage that may have occurred during ship ping If the carton appears to be damaged carefully inspect your fix ture for any damage and be sure all accessories necessary to operate the unit has arrived intact In the case damage has been found or parts are missing please contact our toll free customer support number for further instructions Do not return th...

Page 3: ...female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split ADJ Products LLC www adj com Dotz TPar System User Manual Page 5 Dotz TPar System Set Up Figure 1 Dotz TPar System Safety Precautions ADJ Products LLC www adj com Dotz TPar System User Manual Page 4 To reduce the risk of electrical shock or fire do not expose this unit rain or moi...

Page 4: ...nal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 Figure 4 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for DATA transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors i...

Page 5: ... TPar System User Manual Page 9 Dotz TPar System System Menu The LCD backlight will shut off after 30 seconds to relight the background press the MODE button for 5 seconds DMX Mode Set the DMX Address and DMX Channel Mode 1 Press the MENU button until DMX Mode and underneath ADDR XXX and CH XX is displayed press ENTER 2 XXX will now begin to flash use the UP and DOWN buttons to find your desired D...

Page 6: ...ill allow you to control each individual fixture s traits with a standard DMX 512 controller such as the Elation Show Designer or the Elation DMX Operator 2 To run your fixture in DMX mode follow directions on page 8 to set your DMX address and DMX Channel mode 3 Plug in the fixture via the XLR connections to any standard DMX controller 4 For longer cable runs more than a 100 feet use a terminator...

Page 7: ...n with the MODE pedal it lets you scroll through the static colors and built in programs Press the DOWN pedal for more then 3 seconds to activate connected light 2 left side of the bar Press the pedal for more then 3 seconds to de activate light 2 Dotz TPar System Dotz RF Remote The Dotz RF remote has many different functions and allows you to control your Dotz TPar System from long distance The r...

Page 8: ...OR 6 120 127 COLOR 7 128 135 COLOR 8 136 143 COLOR FADE 1 144 151 COLOR SNAKE 152 159 COLOR FADE 2 160 167 COLOR CHANGE 168 175 COLOR FLOW 1 176 183 COLOR FLOW 2 184 191 COLOR FLOW 3 192 199 COLOR FLOW 4 200 207 COLOR FLOW 5 208 215 COLOR FLOW 6 216 223 COLOR FLOW 7 Dotz TPar System 9 Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 Dotz TPar System 3 Ch...

Page 9: ...239 COLOR FLOW 9 240 255 SOUND ACTIVE 5 MASTER DIMMER PROGRAM SPEED SOUND SENSITIVITY 0 255 MASTER DIMMER 0 100 0 255 PROGRAM SPEED SLOW FAST 0 255 SOUND SENSITIVITY LEAST MOST 6 STROBING 0 255 SLOW FAST 7 DIMMER CURVES 0 41 STANDARD 42 84 STAGE 85 127 TV 128 170 ARCHITECTURAL 171 213 THEATER 214 255 DEFAULT TO UNIT CURVE SETTING 8 LIGHT 1 IF APPICABLE 0 127 LIGHT 1 OFF 128 255 LIGHT 1 ON 9 LIGHT ...

Page 10: ...OLOR 1 Dotz TPar System 18 Channel Mode Channel Value Function 13 COLOR MACROS PROGRAMS 80 87 COLOR 2 88 95 COLOR 3 96 103 COLOR 4 104 111 COLOR 5 112 119 COLOR 6 120 127 COLOR 7 128 135 COLOR 8 136 143 COLOR FADE 1 144 151 COLOR SNAKE 152 159 COLOR FADE 2 160 167 COLOR CHANGE 168 175 COLOR FLOW 1 176 183 COLOR FLOW 2 184 191 COLOR FLOW 3 192 199 COLOR FLOW 4 200 207 COLOR FLOW 5 208 215 COLOR FLO...

Page 11: ...alues of 240 255 Channel 14 will control sound sensitivity If extra lights are attached to the top of the bar Channels 17 18 will control the lights Dotz TPar System Power Cord Daisy Chaining With this feature you can connect the fixtures to one another using the IEC input and output sockets The quantity that can be connected is 7 fixtures maximum for 120V and 14 fixtures maxi mum for 230V After t...

Page 12: ...he fuse holder located inside the power socket Insert a flat head screw driver into the power socket and gently pry out the fuse holder Remove the bad fuse and replace with a new one The fuse holder has a built in socket for a spare fuse be sure not to confuse the spare fuse with active fuse Dotz TPar System Alternate Lighting Installation A special feature that this system has is that you are abl...

Page 13: ...g the period specified above ADJ Products LLC will replace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole disc...

Page 14: ...tion Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Auto Sensing Voltage This fixture contains a automatic volt age switch which will auto sense the voltage when it is plugged into the power source Dotz TPar System Specifications ADJ Products LLC 6122 S Eastern Ave Los Angeles CA...

Reviews: