background image

Focus Spot 2X

Introduction

Unpacking: Thank you for purchasing the Focus Spot 2X by ADJ Products, LLC. Every unit has been 

thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping 

carton for damage that may have occurred during shipping. If the carton appears to be damaged, 

carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit 

has arrived intact. In the case damage has been found or parts are missing, please contact our toll free 

customer support number for further instructions. Do not return this unit to your dealer without first 

contacting customer support. 
Introduction: The Focus Spot 2X is a DMX intelligent, moviing head, LED fixture. This fixture can be 

used  in  a  stand  alone  mode  or  connected  in  a 

Primary/Secondary

 

configuration.  This product 

is intended to be used by professionally trained personnel only and is not suitable for private 

use. 
These instructions contain important safety information regarding the use and maintenance of 
this  unit. Please keep this manual with the unit, for future reference. 

Customer Support: Contact ADJ Service for any product related service and support needs. Also 

visit 

forums.adj.com

 with questions, comments or suggestions.

Parts: To purchase parts online visit: 

http://parts.americandj.com  

(US)

http://www.adjparts.eu  

(EU)

ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST

Voice: 800-322-6337 | Fax: 323-832-2941 | [email protected]
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET 

Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | [email protected]

ADJ PRODUCTS LLC USA 

6122 S. Eastern Ave. Los Angeles, CA. 90040

323-582-2650 | Fax 323-532-2941 | 

www.adj.com

 | 

[email protected]

ADJ SUPPLY Europe B.V

Junostraat 2 6468 EW Kerkrade, The Netherlands

+31 (0)45 546 85 00 | Fax +31 45 546 85 99

www.adj.eu

 | 

[email protected]

ADJ PRODUCTS GROUP Mexico

AV Santa Ana 30 Parque Industrial Lerma, Lerma, Mexico 52000

+52 (728) 282-7070

Caution! 

There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, 

doing so will void your manufactures warranty. In the unlikely event your unit may require service 

please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.

ADJ Products, LLC  -  www.adj.com  - Focus Spot 2X User Manual Page 3

Summary of Contents for 1227000010

Page 1: ...User Instructions FOCUS SPOT 2X lntertek 4000358 ...

Page 2: ...two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC RADIO FREQUENCY INTERFERENCE WARNINGS INSTRUCTIONS This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules These limits are designed to provide reasonable protection against har...

Page 3: ...MX Addressing DMX Modes Values System Menu Primary Secondary Set Up I Manual Zoom Offset Menu UC IR Airstream Remote Control Target Mode Dimmer Curve Chart Gobo Replacement I Gobos Remove the Head Casing Dimensional Drawings Fuse Replacement I Multiple Unit Power Linking Trouble Shooting I Cleaning Limited Warranty USA Only Technical Specifications 3 4 5 8 9 11 13 14 17 20 21 23 24 25 26 27 28 29 ...

Page 4: ...enance of this unit Please keep this manual with the unit for future reference Customer Support Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions Parts To purchase parts online visit http parts americandj com US http www adjparts eu EU ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST Voice 800 322 6337 Fax 323 8...

Page 5: ...he shipping carton If the unit is under warranty you must provide a copy of your proof of purchase invoice You may obtain a R A number by con tacting our customer support team on our customer support number All packages returned to the service department not displaying a R A number on the outside of the package will be returned to the shipper ADJ Products LLC www adj com Focus Spot 2X User Manual ...

Page 6: ... this unit if it becomes damaged During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by...

Page 7: ...OTHING AND OR USING UV PAINTS ON SKIN AVOID DIRECT EYE AND OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet 3 3m DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT RADIATION OUTPUT INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS SUNLIGHT EXPOSURE DISORDERS ...

Page 8: ...risms animation wheels frost filters iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there is no true way to fully prevent this issue from happening the guidelines below can prevent any potential damage from occurring if followed Contact ADJ Service for mo...

Page 9: ...cus Spot 2X Overview 7 8 9 10 1 2 3 4 5 6 1 IR Receiver 2 Primary Active LED 3 LCD Display MENU Button UP Button DOWN Button ENTER Button 4 Sound Active LED 5 Secondary Active LED 6 DMX Active LED 7 Manual Zoom Control 8 3 Pin DMX In Out 9 Power In Out 10 Fuse 3 15A ...

Page 10: ... page Never use the carrying handles for secondary attachment When installing the unit the trussing or area of installation must be able to hold 10 times the weight without any deformation When installing the unit must be secured with a secondary safety attachment e g and appropriate safety cable Never stand directly below the unit when mounting removing or servicing the unit Overhead mounting req...

Page 11: ...ssing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw NOTICE The suitable enviromental temperature for this lighting fixture is between 25 C to 45 C Do not place this lighting fixture in an enviroment where the temperatures are under or above the temperatures stated above This will allow the fixture to run at its best and help prolong the fixture life SAF...

Page 12: ...n The Focus Spot 2X can be controlled via DMX 512 protocol The DMX address is set on the front panel of the Focus Spot 2X Your unit and your DMX controller require a standard 3 pin XLR connector for data input and data output Figure 1 We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all pro...

Page 13: ...ation reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 Figure 4 5 Pin XLR DMX Connectors Some manufactures use 5 pin DMX 512 data cables for DATA trans mission in place of 3 pin 5 pin DMX fixtures may be implemented in a 3 pin DMX line Wh...

Page 14: ...fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of DMX channels of each fixture That means changing the setting...

Page 15: ... Gobo 2 Shake Gobo 3 Shake Gobo 4 Shake Gobo 5 Shake Gobo 6 Shake Clockwise Rotation Fast Slow Stop Counter Clockwise Rotation Fast Slow 000 009 010 018 019 027 028 036 037 046 047 055 056 063 064 073 074 082 083 091 092 100 101 110 111 119 120 127 128 189 190 193 194 255 4 6 RGOBO ROTATING GOBO Indexing Clockwise Rotation Slow Fast Stop Counter Clockwise Rotation Fast Slow 000 127 128 189 190 193...

Page 16: ...D On Slow Open Fast Close LED On Fast Open Slow Close LED On Random Strobing Slow Fast LED On 000 007 008 015 016 131 132 139 140 181 182 189 190 231 232 239 240 247 248 255 9 11 SHOWS Off Show 1 Show 2 Show 3 Show 4 Random Show Sound Active 0 001 021 022 041 042 061 062 081 082 255 12 14 SHUTTER STROBE 8 10 MASTER DIMMER 000 255 0 100 10 12 UV MASTER DIMMER 000 255 0 100 11 13 FOCUS 000 255 0 100...

Page 17: ...ovement Disable Blackout with Pan Tilt Movement Enable Blackout with Color Change Disable Blackout with Color Change Enable Blackout with Gobo Change Disable Blackout with Gobo Change Pan Tilt Reset Color Wheel Reset Gobo Wheel Reset Effect Reset No Function Reset All No Function 000 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 199 200 209 210 255 16 18 ...

Page 18: ...2X System Menu SYSTEM MENU settings and adjustments are made See image below During normal operation pressing the MENU UP and DOWN buttons When you reach ENTER UP and DOWN ENTER You may exit the main menu at any time without making any adjustments by pressing the MENU button ...

Page 19: ...ode Selection Target Mode Sound Mode Activation On Off Sound Mode Sound Sensitivity Adjustment 0 100 Sound Sense DMX State Setting Pri Sec Blackout Last State DMX State Dimmer Curve Dimming Curve Setting Standard Stage TV Architec Theatre Pan Invert Pan Inversion Normal Invert Tilt Invert Tilt Inversion Normal Invert Back Light Back Light Setting On Off Auto Test Auto Test LED Temp Current LED Tem...

Page 20: ...en in this submenu is the running mode the fixture will go into when the DMX signal is lost Listed below are the 3 modes Pri Sec Mode This setting will have the fixture automatically go into primary secondary setup The unit will go into the setting that is selected under SECONDARY MODE Blackout This setting will have the fixture automatically go into stand by mode blackout Last State This setting ...

Page 21: ...he last unit in the chain will use the male XLR connector only For longer cable runs we suggest a terminator at the last fixture 2 On the Primary unit press the MENU button until Secondary Mode is displayed and press ENTER Use the UP and DOWN buttons to scroll to the Primary setting and press ENTER 3 After setting the Primary unit to the primary setting find and set your desired operating mode 4 O...

Page 22: ...ress ENTER to confirm Press the MENU button for one second to exit Tilt Offset Adjustment of the tilt home position 1 Press the ENTER button for at least 5 seconds then press the UP or DOWN buttons so that Tilt Offset is displayed press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit Focus Offset Setting adju...

Page 23: ...ting adjustment for the rotating gobo motor 1 Press the ENTER button for at least 5 seconds then press the UP or DOWN buttons so that R Gobo Offset is displayed press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit Color Offset Setting adjustment for the color wheel 1 Press the ENTER button for at least 5 sec...

Page 24: ...y Full ON Fade Gobo Strobe Color 1 2 3 4 5 6 7 8 9 SoundOn Show0 SoundOff Works with App page 1 STAND BY Pressing this button will blackout the fixture FULL ON Hold this button down to fully light up the unit When you let the button go the unit will return to its previous state FADE GOBO Press this button once to access gobo wheel Use the number buttons to find your desired gobo DIMMER and DIMMER ...

Page 25: ...arget Mode Pan Movement Range 140 Tilt Movement Range 135 Mode 1 Pan Movement Range 140 Tilt Movement Range 135 Mode 2 Pan Movement Range 140 Tilt Movement Range 135 Mode 3 Pan Movement Range 140 Tilt Movement Range 135 Mode 4 Pan Movement Range 540 Tilt Movement Range 270 Mode 0 ...

Page 26: ... 100 50 10 0 Time ms 0 Sec 255 255 0 0 Standard default 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Dimming Curve Ramp Effect Rise Time Down Time 0 sec Fade Time 1 sec Fade Time Rise Time ms Down Time ms Rise Time ms Down Time ms ...

Page 27: ...crewed is now facing up 1 To change a gobo rotate the moving head so that the UV lens is located on top Unscrew the single middle screw See instruction number 1 on the next page 2 Once you loosen the single screw you are able to swing the head back See instruction number 2 on the next page You will now be able to access the gobo wheel Turn the wheel with your hand until you come across the gobo yo...

Page 28: ...s Spot 2X User Manual Page 27 Focus Spot 2X Remove the Head Casing Screw Screw 1 Unscrew the single screw located behind the UV LED 2 Flip the top cover back 3 Carefully remove the lens 4 Unscrew the 4 screws located on the other side ...

Page 29: ...ADJ Products LLC www adj com Focus Spot 2X User Manual Page 28 Focus Spot 2X Dimensional Drawing ...

Page 30: ...g 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog resi due dust dew Focus Spot 2X Multiple Unit Power Linking With this feature you can connect the fixtures to one another using the power cable input an...

Page 31: ...will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear indentifyin...

Page 32: ... Colors Gobos DMX Channels Warranty Please Note this unit and this manual are subject to change Approvals Ratings 100V 240V 50 60Hz 1 x 100W White LED 1 x 3W UV LED Any safe working position 180W 3 15A 9 3 L x 6 9 W x 15 2 H 237 x 175 x 385mm 14 5lbs 6 5 kgs 8 Colors White 6 Gobos Open Inner Diameter 19mm Outer Diameter 23mm Thickness 0 5mm 2 DMX Modes 16 18 2 Year 730 days cETLus CE ...